30 October 2023 in IEEE Transactions on Instrumentation and Measurement
Driver monitoring is a popular topic of investigation. Contactless vital-sign measurement via remote photoplethysmography (rPPG) is an easy and effective alternative to cumbersome wearable devices during driving. However, driving is a noise-heavy situation for remote vital-sign sensing, owing to the disturbances caused by jolted cars or varying illumination from time and weather variations. In this study, we propose deep-learning models for rPPG construction and heart-rate estimation that work for both red-green-blue (RGB) and monochrome near-infrared (NIR) images. The proposed method overcomes the adaptation issues commonly seen in deep-learning based heart-rate estimation approaches and achieves a significant improvement in robustness for heart-rate measurement. To evaluate the performance thoroughly, in addition to a public dataset, we construct four testing driving sets for various practical conditions, including driving at night, on rainy days, and on long-term journeys. It is also worth noting that we conducted the assessment with a cross-dataset protocol to further verify the efficiency of our method. The experimental results on the five datasets show that our proposed method can perform better than the state-of-the-art method for both RGB and NIR images, especially in some challenging cases. The root-mean-square error (RMSE) for the situation with additional head motion conditions can be improved by 28.6% with RGB images and by 21.91% with NIR images on the open dataset. Moreover, RMSE can be improved by up to 42.6% at night, 14.41% on rainy days, and 18.78% on long-term journeys.
3 September 2024 in IEEE Transactions on Instrumentation and Measurement
In recent years, sleep apnea (SA) detection has attracted increasing attention worldwide. Polysomnography (PSG) is currently considered the gold standard for sleep monitoring, but its limitations have hindered widespread adoption. Therefore, we propose a video-based contactless SA detection technique. Only a single camera is needed to capture sleep images, and images of the nose, throat, and face are selected to extract respiratory motion signals and physiological signals, including optical flow, remote photoplethysmography (rPPG), and heart rate variability. These signals are used for SA classification on per-minute segments and to assess the severity of the apnea-hypopnea index (AHI) throughout overnight sleep. Compared with existing methods, our proposed approach has the advantages of being non-contact, low-cost, and easy to use. This allows users to maintain their usual sleep conditions, making monitoring more convenient. In evaluation experiments using a self-constructed rPPG-SA dataset involving 61 participants, the proposed method achieves results comparable to existing contact-based methods with 10 subjects as training data and the other 51 subjects as testing data. The accuracy for binary classification of SA segments reaches 78.45% with a sensitivity of 79.03% and a specificity of 78.12%. In further experiments predicting the severity of AHI over the entire night, the accuracy for detecting moderate and severe levels (AHI ≥ 15) reaches 76.47% with sensitivity of 84.85% and specificity of 61.11%. Therefore, the proposed method not only offers the advantages of convenience and comfort in terms of device usage but also achieves comparable performance to contact-based algorithms.