Pavlo Illiuchenko

Pavlo Illiuchenko

Auto-generated profile, based on publicly available information

Pavlo Illiuchenko

Institute of Scientific Research on Civil Protection of the National University of Civil Protection of Ukraine

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2023 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
YTYuriy Tsapko
Yuriy Tsapko
RLRuslan Likhnyovskyi
Ruslan Likhnyovskyi
АTАleksii Tsapko
Аleksii Tsapko
VKVitalii Kovalenko
Vitalii Kovalenko
OSOksana Slutska
Oksana Slutska
YGYuriy Gulyk
Yuriy Gulyk
An issue related to the use of foaming agents to extinguish fires involving flammable liquids is to ensure the efficiency of vapor insulation of flammable liquid and the foam stability during operation. Therefore, the object of research was a change in the insulating properties of the foaming agent film when interacting with a polar combustible substance. It has been proven that the presence of foaming agent on a flammable liquid leads to the formation of an insulating film on the surface resistant to the combustion temperature of the liquid, due to which re-ignition shifts towards longer time. A film of foaming agent was formed on the surface of the flammable liquid by leaking from the screen, which led to the insulation of the surface. The measured contact area of the foaming film with the electrode was more than 6.2·10-3 m2, which indicates the formation of a barrier for temperature, which collapses over time. According to experimental data on changes in electrical resistance, the critical contact area of the foaming film with the electrode was calculated, at which the film is destroyed. Based on the derived dependences, the change in the process of mass transfer of the foaming film to a flammable liquid was calculated, equal to about 800 s. The maximum possible mass transfer of the foaming agent into the flammable liquid and the reduction of insulation capacity were evaluated. The peculiarities of foam supply to the surface of alcohol through the screen are that the quenching time was about 156 s while the critical intensity of the supply of the working solution of the foaming agent was 0.054 dm3/(m2·s). And the time interval before re-ignition was about 470 s, which is enough to cool the fire site. Thus, there is reason to assert the possibility of targeted control over the processes of extinguishing polar flammable liquids with a foaming agent

28 February 2024 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
YTYuriy Tsapko
Yuriy Tsapko
АTАleksii Tsapko
Аleksii Tsapko
RLRuslan Likhnyovskyi
Ruslan Likhnyovskyi
MSMaryna Sukhanevych
Maryna Sukhanevych
LZLeonid Zapolskiy
Leonid Zapolskiy
OBOlga Bedratiuk
Olga Bedratiuk
An issue related to using SIP panels for building structures is to ensure their stability and durability during operation in wide ranges. Therefore, the object of research was the change in the properties of wood-polymer material in case of fire and its protection when applied with a reactive coating capable of forming a pinocoke layer under the influence of high temperature on the coating. It has been proven that in the process of thermal action on the fire-resistant coating, the heat insulation process of SIP panels involves the formation of soot-like products on the surface of the material. Thus, under the action of the radiation panel on the surface of the OSB sample, after 120 s of thermal exposure, the process of intensive formation of a layer of foam coke, which thermally insulated the wood-polymer material, began; instead, after the radiation panel was exposed to the fire-resistant polystyrene foam sample, the process of destruction began at a temperature of about 100 °C polystyrene foam. When determining the flammability of a fire-resistant SIP panel, it was established that the temperature of the flue gases during the tests was no more than 110 °C, the length of the damaged sample did not exceed 460 mm. At the same time, the mass loss did not exceed 200 g, and independent combustion of the SIP panel sample did not occur despite the high temperature. According to these data, the SIP panel, fire-resistant with a reaction coating, belongs to group G1 (low flammability) and is a non-flammable material. The practical significance is that the results were taken into account during the design of buildings from SIP panels. So, there are reasons to assert the possibility of targeted regulation of the fire protection processes of SIP panels through the use of reactive coatings capable of forming a protective layer on the surface of the material that inhibits the rate of heat transfer

29 April 2023 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
YTYuriy Tsapko
Yuriy Tsapko
RLRuslan Likhnyovskyi
Ruslan Likhnyovskyi
АTАleksii Tsapko
Аleksii Tsapko
VKVitalii Kovalenko
Vitalii Kovalenko
OSOksana Slutska
Oksana Slutska
MSMaryna Sukhanevych
Maryna Sukhanevych
An issue related to using cable products for building structures is to ensure their stability and durability when operating within wide limits. Therefore, the object of research was a change in the properties of the polymer sheath of the cable during the formation of a swollen coating layer under the influence of high temperature. It is proved that in the process of thermal action on the flame retardant coating, the process of thermal insulation of the cable involves the formation of particulate products on the surface of the sample. Under the action of the burner flame, a temperature was reached on the surface of the sample, which led to a swelling of the coating of more than 16 mm. The measured temperature on the inverse surface of the sample was no more than 160 °C, which indicates the formation of a barrier for temperature. In this regard, a calculation and experimental method for determining thermal conductivity when using a flame retardant as a coating has been developed, which makes it possible to estimate the coefficients of temperature conductivity and thermal conductivity under high-temperature action. According to the experimental data and established dependences, the coefficients of temperature conductivity and thermal conductivity of wood were calculated, which are 214.4·10–6 m2/s and 0.62 W/(m∙K), respectively, due to the formation of a heat-insulating swollen layer. The maximum possible temperature penetration through the thickness of the coating was assessed. A temperature was created on the surface of the sample, which significantly exceeds the ignition temperature of the polymer sheath of the cable, and, on a non-heated surface, does not exceed 160 °C. Thus, there is reason to argue about the possibility of directed adjustment of the fire protection processes of an electrical cable by using coatings capable of forming a protective layer on the surface of the material, which inhibits the rate of heat transfer.

22 December 2023 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
YTYuriy Tsapko
Yuriy Tsapko
RLRuslan Likhnyovskyi
Ruslan Likhnyovskyi
АTАleksii Tsapko
Аleksii Tsapko
KBKseniia Bielikova
Kseniia Bielikova
SPSerhii Poteriaiko
Serhii Poteriaiko
OBOlga Bondarenko
Olga Bondarenko
An issue related to using concrete for building structures is to ensure their stability and durability during operation within wide limits. Therefore, the object of research was the change in the properties of concrete in case of fire and its protection when applied with a reactive coating capable of forming a foam coke layer under the influence of high temperature on the coating. It has been proven that in the process of thermal action on the fire-resistant coating, the process of heat insulation of concrete involves the formation of soot-like products on the surface of the material. Thus, under the influence of the flame of the burner, a temperature arose on the surface of the sample, which led to the swelling of the coating by more than 18 mm. The measured temperature on the surface of the concrete sample under the layer of foam coke was no more than 140 °C, which indicates the formation of a fire barrier. In this regard, modeling of the process of heat transfer through the formed layer of foam coke in the process of its protection with a reactive coating was carried out and dependence was established, which makes it possible to estimate the coefficients of temperature conductivity and thermal conductivity during high-temperature action. According to the experimental data and the established dependences, the coefficient of temperature conductivity and heat conductivity of foam coke was calculated, which is 9.17·10–7 m2/s and 0.17 W/(m∙K). The assessment of the maximum possible penetration of fire through the layer of foam coke was carried out. A temperature was formed on the surface of the sample, which significantly exceeded the temperature of the destruction of concrete, and on the surface of concrete under the coating it did not reach 250 °C. So, there are reasons to assert the possibility of targeted regulation of concrete fire protection processes by using reactive coatings capable of forming a protective layer on the surface of the material that inhibits the rate of heat transfer

29 December 2021 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
RKRostyslav Kravchenko
Rostyslav Kravchenko
PIPavlo Illiuchenko
Pavlo Illiuchenko
AOAndrii Onyshchuk
Andrii Onyshchuk
OZOleksandr Zazymko
Oleksandr Zazymko
The test methods for flame propagation of long elements of the electrical wiring system, in particular, cables, cable conduits and ducts, are analyzed, and differences in them are found in the test conditions and criteria for evaluating the resistance to flame propagation. Using a substrate of a wooden board covered with a layer of tissue paper with an areal density of (21±9) g/m2, adopted for testing other elements of the electrical wiring system, a cable was identified that is not resistant to flame propagation. It is proposed to use this substrate for testing the flame propagation of cables instead of a substrate made of a double layer of filter paper with a surface density of (80±15) g/m2. In one of three experiments, a cable that was not resistant to flame propagation was found based on the criterion of the presence of ignition of the substrate located under it. To reduce the risk of making an incorrect decision on compliance, it is proposed that the assessment of long elements of the wiring system be carried out according to the rules established for cable ducts, trays and ladders in EN 50085-1 and IEC 61537. For the AVVG cable with an outer diameter of 10 mm to 60 mm, when it touches the blue flame cone of 1 kW, the correlation coefficient of the dependence of the length of the charred part on the diameter was 0.969. For a distance of 100 mm between the sample and the burner along its axis, a correlation coefficient of 0.985 was obtained. It is proposed to test cables under the second condition recommended in IEC 60695-11-2. For two conduits, flame propagation was revealed when exposed to a 1 kW flame for 120 s and 240 s. However, for these pipelines, flame propagation did not occur under standard conditions of exposure to such a flame for 20 s and 25 s. To identify long elements of the wiring system that are not resistant to flame propagation, it is proposed to test them at a duration of exposure to a flame of 1 kW, established for cables in IEC 60332-1-2

28 August 2025 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
YTYuriy Tsapko
Yuriy Tsapko
ATAleksii Tsapko
Aleksii Tsapko
VLVasyl Lomaha
Vasyl Lomaha
PIPavlo Illiuchenko
Pavlo Illiuchenko
OBOksana Berdnyk
Oksana Berdnyk
NDNataliia Dyuzhilova
Nataliia Dyuzhilova
This study's object is the process that forms fire-resistant biocomposites based on wood chips and inorganic and organic binders. The task addressed relates to the need to enable resistance to high-temperature flames. This is important for the technology of application and production of environmentally friendly biocomposites obtained from natural and renewable sources for construction. It has been proven that when determining the thermal insulation properties of the resulting materials, the temperature conductivity of the biocomposite on an inorganic basis was 0.22·106 m2/s while the thermal conductivity of the sample did not exceed 0.132 W/(m∙K). In contrast, for an organic-based biocomposite, the thermal conductivity value decreases by more than 6 times, the temperature conductivity – by more than 7 times. In addition, the heat capacity of the product based on inorganic binder corresponds to a value within 1.6 kJ/(kg∙K), and the heat capacity value for the product made of biocomposite based on organic basis was 7.66 kJ/(kg∙K), respectively. When a radiation panel was applied to the biocomposite samples, the temperature of the gaseous combustion products increased to 96°C, and the sample did not ignite. A study of the compressive strength of biocomposites showed that the product formed on the basis of wood and inorganic binder is more fragile; the tensile strength corresponds to an average value of 0.5 MPa. In contrast, for the biocomposite formed on the basis of chips and organic binder, the average tensile strength is 2.4 MPa, which is more than 4.7 times higher than the product based on inorganic basis. The practical importance relates to the fact that the results were taken into account when developing a thermal insulation product for construction. Thus, there are grounds for the production of biocomposites for thermal insulation