Hongyang Liu

Hongyang Liu

Auto-generated profile, based on publicly available information

Hongyang Liu

AVIC Xian Flight Automatic Control Research Institute, Xian, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JZJunzhao Zhang
Junzhao Zhang
JLJianrui Liu
Jianrui Liu
HLHui Liu
Hui Liu
Dong JiangDong Jiang
Dong Jiang
YZYechi Zhang
Yechi Zhang
HLHongyang Liu
Hongyang Liu
Active electromagnetic interference (EMI) filters (AEFs) are effective alternatives to passive EMI filters for increasing the power density of switched-mode power converters. This article presents a grounding impedance-based active common-mode (CM) EMI filter (GI-AEF). Unlike conventional filters placed in the primary circuit, the GI-AEF is installed in the grounding loop to suppress CM EMI without bulky transformers. It only handles low-CM currents and avoids needing high gain-bandwidth operational amplifiers, resulting in a compact and cost-effective design. Additionally, the GI-AEF ensures low-grounding voltage even during power failures, enhancing safety. Experimental results show that it reduces filter volume and weight by over 50% while cutting costs by 34%—marking the first instance of cost reduction in the academic literature through AEF technology.

6 November 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JGJiwen Gong
Jiwen Gong
YXYuanhao Xie
Yuanhao Xie
Dong JiangDong Jiang
Dong Jiang
HLHui Liu
Hui Liu
Zicheng LiuZicheng Liu
Zicheng Liu
HLHongyang Liu
Hongyang Liu
Four-module motor drive system consists of four sets of three-phase inverters connected in parallel, and its ample modulation freedom brings potential for EMI suppression. However, existing studies have focused on how to optimize the spatial phase angle of each module, neglecting the use of temporal degrees of freedom. This article first investigates the mechanism and characteristics of the carrier phase-shifting (CPS) strategy for dc-link harmonic suppression and experimentally verify the effect on conducted EMI. Then we synthesize the spatial and temporal degrees of freedom to propose a variable phase-shifting strategy (VCPS). By selecting multiple CPS angles proven effective for EMI suppression and cyclically switching according to a certain temporal pattern, VCPS achieves additional mitigation of EMI peaks. Subsequently, a neural network is constructed to model and predict the EMI spikes and optimize the switching pattern of CPS angles. Finally, the effectiveness of the proposed VCPS strategy and neural network optimization is verified experimentally. The optimized VCPS reduces conducted EMI peaks by 13.6 dB—a 4.6 dB improvement over conventional CPS strategy.

1 October 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
GWGuangyu Wang
Guangyu Wang
HLHongyang Liu
Hongyang Liu
Zicheng LiuZicheng Liu
Zicheng Liu
JYJunnan You
Junnan You
RZRongpei Zhu
Rongpei Zhu
RQRonghai Qu
Ronghai Qu
Compared with healthy electric drive systems, open-circuit faults break the symmetry of the electric drive system, thereby inducing unique common-mode (CM) characteristics. As a result, traditional definitions and analyses of CM voltage (CMV) for health-symmetrical electric drive systems are difficult to quantitatively evaluate the CM noise of fault-asymmetric electric drive systems or guide the design of suppression methods. Therefore, this article models and analyzes the CMV under single-phase bridge open-circuit fault, revealing the formation mechanism of CMV in fault-asymmetric electric drive systems and achieving an accurate definition of CMV. On this basis, an optimized CMV suppression method suitable for faulty electric drive systems is proposed. It employs a dynamic zero-sequence injection scheme to actively cancel the CMV generated by the remaining healthy bridges, and adjusts the carrier phase based on the unique CMV characteristics of the faulty phase to suppress the CMV of the system. The experimental results verify the effectiveness of the proposed CMV modeling and analysis method for the fault-asymmetric system. Meanwhile, compared with traditional methods, the proposed CMV suppression method achieves lower CMV and CM electromagnetic interference (EMI) under single-phase open-circuit fault, providing a reference for the CM evaluation and optimal design of fault-asymmetric electric drive systems.

17 September 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
RZRongpei Zhu
Rongpei Zhu
GYGuang Yang
Guang Yang
HLHongyang Liu
Hongyang Liu
LFLongyuan Fan
Longyuan Fan
Zicheng LiuZicheng Liu
Zicheng Liu
RQRonghai Qu
Ronghai Qu
In motor drive system fed by voltage source inverter, common-mode voltage (CMV) is commonly present because of pulsewidth modulation (PWM) techniques. It is proved to be feasible in research to collect energy from CMV and provide a dc power source for low-power sensors such as encoders. This approach can replace auxiliary power supply, thus, simplifying system wiring design. However, the practicality of this approach will be largely constrained by the maximum power available from CMV, as it directly affects the stable operation of sensors. This article aims to explore methods to improve the power capacity with low cost. A common-mode (CM) power transfer model is constructed to clarify the factors influencing CM power extraction and analyze possible methods for increasing power capacity. Then, from the perspective of power source, the characteristics of CMV are analyzed including its frequency composition and rms value. Further exploration is conducted to analyze the influence of zero-sequence injection during modulation on the characteristics of CMV. At last, a discontinuous PWM method DPWM3 is identified as the most effective PWM method to significantly enhance power capacity. Experimental results validate the accuracy of quantitative analysis and effectiveness of the proposed method.