Zicheng Liu
The displacement sensor is of vital importance for the levitation control of the active magnetic bearing (AMB). For the most widely used eddy current sensor (ECS), it is easy to be affected by electromagnetic interference (EMI) produced by the high-frequency switching of the AMB drive converter. This phenomenon has been sophisticatedly researched in this article. The circuit model of the ECS along with its conditioning circuits have been constructed to predict the conducted EMI in the sensor up to 30 MHz. The mechanism of the EMI on sensor signals have been analyzed. The impact of high-frequency EMI on low-frequency closed-loop control has also been explained. The suppression methods of the EMI effect on the ECS have been proposed based on either high-frequency or low-frequency mechanism. The experiment results have shown that the constructed model can well predict the effect of EMI in the ECS, and the proposed suppression method can significantly improve the measurement accuracy of the ECS.

8 October 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YXYuanhao Xie
Yuanhao Xie
Dong JiangDong Jiang
Dong Jiang
HLHui Liu
Hui Liu
Zicheng LiuZicheng Liu
Zicheng Liu
The active magnetic bearing (AMB) driven by power electronic converters is an emerging technique in the industry to suspend high-speed rotating machinery. The high-frequency switching of the converter can bring electromagnetic interference (EMI) to the system, affecting its reliable operation. This article focuses on the modeling of common mode (CM) EMI in multiaxis AMB systems. The impedance characteristics should be measured online due to the variation of rotor position. Thus, the multiaxis online impedance measurement scheme has been proposed in this article. The impedance measurement requires consideration of both signal-to-noise ratio and independence of different excitation tests. The CM equivalent circuit model has also been built and the parameters have been extracted with a two-step fitting scheme. The experiment has been done to prove the effectiveness of the proposed model. With the proposed method, the CM EMI of multiaxis AMB can be precisely predicted. Furthermore, the CM EMI filter has been designed for the AMB based on the proposed model.

12 June 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
YXYuanhao Xie
Yuanhao Xie
JZJiahua Zhang
Jiahua Zhang
Dong JiangDong Jiang
Dong Jiang
Zicheng LiuZicheng Liu
Zicheng Liu
LTLiangchen Tian
Liangchen Tian
Integrated starter/generator (ISG) is an important facility in transportation power systems. Using power electronics based motor emulator (ME) to test the motor controller is an emerging technique to optimize the design process of the motor drive system. In this paper, an ME is designed to test the control system of ISG in the full operation process. Facing the challenge of dual-mode emulation, a voltage-in-voltage-out interface is proposed to handle the causality problem caused by operation mode change during the starting/generating process. The LCL interface with predictive voltage closed-loop control is proposed to ensure emulation accuracy. A prototype of ME has been developed. The experiment has been done to validate the performance of the emulator, showing that the proposed method can be used to test the ISG controller in full operational mode with accuracy and fast dynamics.

14 January 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JDJianfu Ding
Jianfu Ding
YXYuanhao Xie
Yuanhao Xie
Dong JiangDong Jiang
Dong Jiang
Zicheng LiuZicheng Liu
Zicheng Liu
YSYixuan Shuai
Yixuan Shuai
MZMingqu Zhou
Mingqu Zhou
Multilevel power conversion technology represents a significant advancement in the field of power electronics, and the active magnetic bearing (AMB) drive is a typical power electronics equipment. This article introduces a novel hybrid neutral point clamped (NPC) multilevel AMB drive that incorporates a flying-capacitor (FC) leg, merging traditional NPC structures with the FC configuration. It upgrades the voltage levels of the magnetic bearing (MB) windings from three to five levels, thereby enhancing the system's voltage capacity and facilitating swifter current response times. Additionally, at the same voltage level, this approach improves the electromagnetic interference (EMI) characteristics of the AMB drive, diminishes current ripple and power loss, and improves the suspension precision of the MB. The efficacy of the proposed topology and its control methods has been rigorously validated on a MB blower experimental platform, demonstrating their practical applicability and performance benefits.

28 May 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YSYixuan Shuai
Yixuan Shuai
MZMingqu Zhou
Mingqu Zhou
YCYihua Chen
Yihua Chen
YXYuanhao Xie
Yuanhao Xie
JDJianfu Ding
Jianfu Ding
Zicheng LiuZicheng Liu
Zicheng Liu
Switch short-circuit failures pose significant reliability challenges to active magnetic bearing (AMB) systems, yet existing fault-tolerant strategies predominantly rely on hardware redundancy with limited control-oriented solutions. This article overturns the conventional assumption that faulty H-bridge loses current controllability. It reveals their retained operational capacity despite compromised force capability. The key innovation lies in identifying freewheeling mode's pivotal role in postfault current dynamics. Via a detailed analysis of faulty circuits, this article defines the boundaries of current change rates and proposes a universal maximal force capacity strategy by optimizing current distribution with variable bias current control. Experimental results confirm the proposed method's effectiveness, offering a more robust solution for switch short-circuit failures.

28 May 2021
Verified
Conference Paper
Closed access
JMJoshua John Mlay
Joshua John Mlay
YXYuanhao Xie
Yuanhao Xie
Dong JiangDong Jiang
Dong Jiang
This paper introduces the modulation method for paralleled inverters to reduce the leakage current through achieving zero Common-Mode (CM) voltage of the transformerless Photovoltaic (PV) grid-connected systems. PV arrays are tied to paralleled inverters, which are interconnected to the grid via coupling inductors. The reference Voltage Vector (VV) and the paralleled VV are combined based on VV in each inverter. Zero-CM voltage is attained by distributing the action time to each inverter. The proposed Pulse-Width Modulation (PWM) approach guarantees that the voltages for both inverters are in equilibrium during every switching cycle; the circulating current between the paralleled inverters is limited by a small value of coupling inductance. The PWM method has the benefit of reducing CM leakage current, and output current ripples. Simulation and experimental results of the proposed method are provided, validating its ability to eliminate CM voltage and suppress the CM leakage current.