Cerebral ischemic stroke causes injury to brain tissue characterized by a complex cascade of neuronal and vascular events. Imaging during the early stages of its development allows prediction of tissue infarction and penumbra so that optimal intervention can be determined in order to salvage brain function impairment. Therefore, there is a critical need for novel imaging techniques that can characterize brain injury in the earliest phases of the ischemic stroke. This paper examined optical coherence tomography (OCT) for imaging acute injury in experimental ischemic stroke in vivo. Based on endogenous optical scattering signals provided by OCT imaging, we have developed a single, integrated imaging platform enabling the measurement of changes in blood perfusion, blood flow, erythrocyte velocity, and light attenuation within a cortical tissue, during focal cerebral ischemia in a mouse model. During the acute phase (from 5 min to the first few hours following the blood occlusion), the multi-parametric OCT imaging revealed multiple hemodynamic and tissue scattering responses in vivo, including cerebral blood flow deficits, capillary non-perfusion, displacement of penetrating vessels, and increased light attenuation in the cortical tissue at risk that are spatially correlated with the infarct core, as determined by postmortem staining with triphenyl-tetrazolium chloride. The use of multi-parametric OCT imaging may aid in the comprehensive evaluation of ischemic lesions during the early stages of stroke, thereby providing essential knowledge for guiding treatment decisions.
Optical coherence tomography angiography (OCTA) is increasingly becoming a popular inspection tool for biomedical imaging applications. By exploring the amplitude, phase and complex information available in OCT signals, numerous algorithms have been proposed that contrast functional vessel networks within microcirculatory tissue beds. However, it is not clear which algorithm delivers optimal imaging performance. Here, we investigate systematically how amplitude and phase information have an impact on the OCTA imaging performance, to establish the relationship of amplitude and phase stability with OCT signal-to-noise ratio (SNR), time interval and particle dynamics. With either repeated A-scan or repeated B-scan imaging protocols, the amplitude noise increases with the increase of OCT SNR; however, the phase noise does the opposite, i.e. it increases with the decrease of OCT SNR. Coupled with experimental measurements, we utilize a simple Monte Carlo (MC) model to simulate the performance of amplitude-, phase- and complex-based algorithms for OCTA imaging, the results of which suggest that complex-based algorithms deliver the best performance when the phase noise is < ~40 mrad. We also conduct a series of in vivo vascular imaging in animal models and human retina to verify the findings from the MC model through assessing the OCTA performance metrics of vessel connectivity, image SNR and contrast–to–noise ratio. We show that for all the metrics assessed, the complex-based algorithm delivers better performance than either the amplitude- or phase–based algorithms for both the repeated A-scan and the B-scan imaging protocols, which agrees well with the conclusion drawn from the MC simulations.
We propose a robust non-contact method to accurately estimate peripheral oxygen saturation (SpO2) using a smartphone-based imaging photoplethysmography. The method utilizes the built-in color camera as a remote sensor and the built-in flashlight as illumination to estimate the SpO2. Following the ratio of ratios between green and red channels, we introduce a multiple linear regression algorithm to improve the SpO2 estimation. The algorithm considers the ratio of ratios and the reflectance images recorded at the RGB channels during a calibration process to obtain a set of weighting coefficients to weigh each contributor to the final determination of SpO2. We demonstrate the proposed smartphone-based method of estimating the SpO2 on five healthy volunteers whose arms are conditioned by a manual pressure cuff to manipulate the SpO2 between 90∼100% as detected simultaneously by a medical-grade pulse oximeter. Experimental results indicate that the overall estimated error between the smartphone and the reference pulse oximeter is 0.029 ± 1.141%, leading to a 43% improvement over the conventional ratio of ratios method (0.008 ± 2.008%). In addition, the data sampling time in the current method is 2 seconds, similar to the sampling cycle used in the commercial medical-grade pulse oximeters.
16 July 2020 in Journal of Cerebral Blood Flow & Metabolism
The leptomeningeal collateral status is an independent predictor of stroke outcome. By means of optical coherent tomography angiography to compare two mouse strains with different extent of native leptomeningeal collateralization, we determined the spatiotemporal dynamics of collateral flow and downstream hemodynamics following ischemic stroke. A robust recruitment of leptomeningeal collateral flow was detected immediately after middle cerebral artery (MCA) occlusion in C57BL/6 mice, with continued expansion over the course of seven days. In contrast, little collateral recruitment was seen in Balb/C mice during- and one day after MCAO, which coincided with a greater infarct size and worse functional outcome compared to C57BL/6, despite a slight improvement of cortical perfusion seven days after MCAO. Both strains of mice experienced a reduction of blood flow in the penetrating arterioles (PA) by more than 90% 30-min after dMCAO, although the decrease of PA flow was greater and the recovery was less in the Balb/C mice. Further, Balb/C mice also displayed a prolonged greater heterogeneity of capillary transit time after dMCAO in the MCA territory compared to C57BL/6 mice. Our data suggest that the extent of native leptomeningeal collaterals affects downstream hemodynamics with a long lasting impact in the microvascular bed after cortical stroke.
We report the use of an electrically tunable lens (ETL) in a 1.3 μm spectral-domain optical coherence tomography (SD-OCT) system to overcome the depth of focus (DOF) limitation in conventional OCT systems for OCT angiography (OCTA) in a mouse cerebral cortex. The ETL provides fast and dynamic control of the axial focus of the probe beam along the entire range of the mouse cortex, upon which we performed cerebral blood flow imaging of all cortical layers by stitching the OCTA images automatically captured at six focal depths. Capillary vasculature and axial blood flow velocity were revealed in distinctive cortical layers and, for the first time, to the best of our knowledge, in white matter. The results have shown the system capability to conveniently investigate the hemodynamics in deep cortical layers in the mouse brain. More importantly, the compact integration of an ETL will benefit the future design of handheld or intra-cavity OCT probes for a wide range of applications in research and clinical fields.
Identification, sorting, and sequencing of individual cells directly from in situ samples have great potential for in‐depth analysis of the structure and function of microbiomes. In this work, based on an artificial intelligence (AI)‐assisted object detection model for cell phenotype screening and a cross‐interface contact method for single‐cell exporting, we developed an automatic and index‐based system called EasySort AUTO, where individual microbial cells are sorted and then packaged in a microdroplet and automatically exported in a precisely indexed, “One‐Cell‐One‐Tube” manner. The target cell is automatically identified based on an AI‐assisted object detection model and then mobilized via an optical tweezer for sorting. Then, a cross‐interface contact microfluidic printing method that we developed enables the automated transfer of cells from the chip to the tube, which leads to coupling with subsequent single‐cell culture or sequencing. The efficiency of the system for single‐cell printing is >93%. The throughput of the system for single‐cell printing is ~120 cells/h. Moreover, >80% of single cells of both yeast and Escherichia coli are culturable, suggesting the superior preservation of cell viability during sorting. Finally, AI‐assisted object detection supports automated sorting of target cells with high accuracy from mixed yeast samples, which was validated by downstream single‐cell proliferation assays. The automation, index maintenance, and vitality preservation of EasySort AUTO suggest its excellent application potential for single‐cell sorting.