Siddharth Sourabh Sahu

Siddharth Sourabh Sahu

Auto-generated profile, based on publicly available information

Siddharth Sourabh Sahu

Dept of Applied Physics, School of Engineering Sciences KTH Royal Institute of Technology Stockholm Sweden

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2019 in ACS Sensors
Verified
Journal Article
Closed access
SCSara Cavallaro
Sara Cavallaro
JHJosef Horak
Josef Horak
PHPetra Hååg
Petra Hååg
DGDhanu Gupta
Dhanu Gupta
CSChristiane Stiller
Christiane Stiller
DADev Apurba
Dev Apurba

2 September 2021 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
SSSiddharth Sourabh Sahu
Siddharth Sourabh Sahu
SCSara Cavallaro
Sara Cavallaro
PHPetra Hååg
Petra Hååg
ÁNÁbel Nagy
Ábel Nagy
AKAmelie Eriksson Karlström
Amelie Eriksson Karlström
DADev Apurba
Dev Apurba
We present an approach to improve the detection sensitivity of a streaming current-based biosensor for membrane protein profiling of small extracellular vesicles (sEVs). The experimental approach, supported by theoretical investigation, exploits electrostatic charge contrast between the sensor surface and target analytes to enhance the detection sensitivity. We first demonstrate the feasibility of the approach using different chemical functionalization schemes to modulate the zeta potential of the sensor surface in a range −16.0 to −32.8 mV. Thereafter, we examine the sensitivity of the sensor surface across this range of zeta potential to determine the optimal functionalization scheme. The limit of detection (LOD) varied by 2 orders of magnitude across this range, reaching a value of 4.9 × 106 particles/mL for the best performing surface for CD9. We then used the optimized surface to profile CD9, EGFR, and PD-L1 surface proteins of sEVs derived from non-small cell lung cancer (NSCLC) cell-line H1975, before and after treatment with EGFR tyrosine kinase inhibitors, as well as sEVs derived from pleural effusion fluid of NSCLC adenocarcinoma patients. Our results show the feasibility to monitor CD9, EGFR, and PD-L1 expression on the sEV surface, illustrating a good prospect of the method for clinical application.

1 March 2020 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
SSSiddharth Sourabh Sahu
Siddharth Sourabh Sahu
CSChristiane Stiller
Christiane Stiller
SCSara Cavallaro
Sara Cavallaro
AKAmelie Eriksson Karlström
Amelie Eriksson Karlström
JLJan Linnros
Jan Linnros
DADev Apurba
Dev Apurba
Electrokinetic principles such as streaming current and streaming potential are extensively used for surface characterization. Recently, they have also been used in biosensors, resulting in enhanced sensitivity and simpler device architecture. Theoretical models regarding streaming current/potential studies of particle-covered surfaces have identified features such as the particle size, shape and surface charge to influence the electrokinetic signals and consequently, the sensitivity and effective operational regime of the biosensor. By using a set of well-characterized proteins with varying size and net surface charge, this article experimentally verifies the theoretical predictions about their influence on the sensor signal. Increasing protein size was shown to enhance the signal when their net surface charge was either opposite to that of the sensor surface, or close to zero, in agreement with the theoretical predictions. However, the effect gradually saturated as the protein size exceeded the coulomb screening length of the electrolyte. In contrast, the proteins containing the same type of charge as the surface showed little or no difference, except that the signal inverted. The magnitude of the surface charge was also shown to influence the signal. The sensitivity of the technique for protein detection varied over two orders of magnitude, depending upon the size and surface charge. Furthermore, the capacity of the electrokinetic method for direct electrical detection of various proteins, including those carrying little or no net electric charges, is demonstrated.

1 September 2016 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
VSVantari Siva
Vantari Siva
SSSiddharth S. Sahu
Siddharth S. Sahu
DDD.P. Datta
D.P. Datta
PPP.C. Pradhan
P.C. Pradhan
MNM. Nayak
M. Nayak
PSPratap K. Sahoo
Pratap K. Sahoo

9 February 2023 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
SSSiddharth S. Sahu
Siddharth S. Sahu
Moein Talebian GevariMoein Talebian Gevari
Moein Talebian Gevari
ÁNÁbel Nagy
Ábel Nagy
MGMaxime Gestin
Maxime Gestin
PHPetra Hååg
Petra Hååg
ADApurba Dev
Apurba Dev
High heterogeneity in the membrane protein expression of small extracellular vesicles (sEVs) means that bulk methods relying on antibody-based capture for expression analysis have a drawback that each type of antibody may capture a different sub-population. An improved approach is to capture a representative sEV population, without any bias, and then perform a multiplexed protein expression analysis on this population. However, such a possibility has been largely limited to fluorescence-based methods. Here, we present a novel electrostatic labelling strategy and a microchip-based all-electric method for membrane protein analysis of sEVs. The method allows us to profile multiple surface proteins on the captured sEVs using alternating charge labels. It also permits the comparison of expression levels in different sEV-subtypes. The proof of concept was tested by capturing sEVs both non-specifically (unbiased) as well as via anti-CD9 capture probes (biased), and then profiling the expression levels of various surface proteins using the charge labelled antibodies. The method is the first of its kind, demonstrating an all-electrical and microchip based method that allows for unbiased analysis of sEV membrane protein expression, comparison of expression levels in different sEV subsets, and fractional estimation of different sEV sub-populations. These results were also validated in parallel using a single-sEV fluorescence technique.

7 June 2024 in ACS Sensors
Verified
Journal Article
Open access
Moein Talebian GevariMoein Talebian Gevari
Moein Talebian Gevari
SSSiddharth Sourabh Sahu
Siddharth Sourabh Sahu
FSFredrik Stridfeldt
Fredrik Stridfeldt
PHPetra Hååg
Petra Hååg
LPLuigi De Petris
Luigi De Petris
DADev Apurba
Dev Apurba
Detection of analytes using streaming current has previously been explored using both experimental approaches and theoretical analyses of such data. However, further developments are needed for establishing a viable microchip that can be exploited to deliver a sensitive, robust, and scalable biosensor device. In this study, we demonstrated the fabrication of such a device on silicon wafer using a scalable silicon microfabrication technology followed by characterization and optimization of this sensor for detection of small extracellular vesicles (sEVs) with sizes in the range of 30 to 200 nm, as determined by nanoparticle tracking analyses. We showed that the sensitivity of the devices, assessed by a common protein-ligand pair and sEVs, significantly outperforms previous approaches using the same principle. Two versions of the microchips, denoted as enclosed and removable-top microchips, were developed and compared, aiming to discern the importance of high-pressure measurement versus easier and better surface preparation capacity. A custom-built chip manifold allowing easy interfacing with standard microfluidic connections was also constructed. By investigating different electrical, fluidic, morphological, and fluorescence measurements, we show that while the enclosed microchip with its robust glass-silicon bonding can withstand higher pressure and thus generate higher streaming current, the removable-top configuration offers several practical benefits, including easy surface preparation, uniform probe conjugation, and improvement in the limit of detection (LoD). We further compared two common surface functionalization strategies and showed that the developed microchip can achieve both high sensitivity for membrane protein profiling and low LoD for detection of sEV detection. At the optimum working condition, we demonstrated that the microchip could detect sEVs reaching an LoD of 104 sEVs/mL (when captured by membrane-sensing peptide (MSP) probes), which is among the lowest in the so far reported microchip-based methods.