Sherry S. Huang

Sherry S. Huang

Auto-generated profile, based on publicly available information

Sherry S. Huang

Research and Scientific Affairs, GE HealthCare , Rochester, MN, 55901

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2021 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
SJStephen P. Jordan
Stephen P. Jordan
SHSiyuan Hu
Siyuan Hu
IRIgnacio Rozada
Ignacio Rozada
DMDebra F. McGivney
Debra F. McGivney
RBRasim Boyacioğlu
Rasim Boyacioğlu
DMDan Ma
Dan Ma
Significance: Magnetic resonance is a widely used noninvasive medical imaging technology. Most clinical MRI scans generate qualitative or “weighted” images. A recent new technology, magnetic resonance fingerprinting (MRF), simultaneously extracts quantitative voxel-by-voxel measurements of multiple intrinsic tissue properties such as T 1 and T 2 relaxation rates in a single scan, rapid enough for clinical use. These have been used for tumor characterization, epilepsy lesion detection, and for estimating variability of tissues in asymptomatic subjects. Here, we find that detailed computer models of random and systematic errors can be combined with physics-inspired optimization heuristics to discover MRF pulse sequences achieving substantially improved performance relative to MRF pulse sequences previously designed by human experts.

5 May 2021 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
SHSherry S. Huang
Sherry S. Huang
RBRasim Boyacioglu
Rasim Boyacioglu
RBReid Bolding
Reid Bolding
CMChristina MacAskill
Christina MacAskill
YCYong Chen
Yong Chen
MGMark A. Griswold
Mark A. Griswold

3 March 2026 in Radiology Advances
Verified
Journal Article
Open access
SHSherry S Huang
Sherry S Huang
XWXinzeng Wang
Xinzeng Wang
PLPatricia Sheu Lan
Patricia Sheu Lan
Milica MedvedMilica Medved
Milica Medved
NKNurullah Kaya
Nurullah Kaya
AOAytekin Oto
Aytekin Oto
Background: MR diffusion-weighted imaging (DWI), especially at high b-value, is a key acquisition to help identify clinically significant prostate cancer; however, it suffers from low signal-to-noise ratio (SNR), high noise floor, and susceptibility artifact. Purpose: To demonstrate the feasibility of improving DWI quality using a novel 50-channel pelvic coil in conjunction with a deep learning (DL)-based phase correction and a DL-denoising algorithm. Methods: In this prospective, single-center study, 24 consecutive men referred for prostate multiparametric MRI over 16 months were enrolled (age 47–79 years; mean, 68.1 years). Axial T2-weighted images and DWI were obtained using a prototype 50‑channel coil and standard clinical phased array (3 T Architect, GE HealthCare, USA). The DWI acquisitions were reconstructed with the vendor’s deep learning denoising algorithm (ARDL). The same raw data were reconstructed offline using an investigational DL Phase Correction algorithm with ARDL (DLPC+ARDL). Two independent readers scored DWI and ADC series using 4 qualitative criteria. SNR and contrast-to-noise ratio (CNR) were measured on b = 1500 s/mm2 images. Combined reader scores were compared using the Wilcoxon matched‑pairs signed‑rank test, inter‑reader variability was assessed using Cohen’s κ, and quantitative SNR/CNR values were compared using 2‑tailed paired t‑tests. Results: Twenty men were analyzable for qualitative and 18 for quantitative metrics (reported as mean ± SD). 50‑channel pelvic coil with DLPC+ARDL produced the highest SNR (99.70 ± 28.50) and CNR (91.68 ± 44.39), exceeding 50‑channel with ARDL alone (SNR 56.44 ± 28.50; CNR 51.11 ± 28.67), 30‑channel anterior array with ARDL (SNR 31.41 ± 13.18; CNR 26.26 ± 13.52), and DLPC + ARDL (SNR 49.4 ± 18.6; CNR 44.7 ± 18.3) (all P < .0001). Reader scores favored DLPC+ARDL in prostate border definition, peripheral/transition zone distinction, lesion conspicuity, and confidence of extraprostatic extension (all P values for DWI at b = 1500 s/mm2 < 0.0001; synthetic DWI at b = 2000 s/mm2: P = 7.5 × 10−7–0.01). Inter‑reader agreement was fair for acquired DWI (quadratic‑weighted κ = 0.34) and lower for synthetic DWI (κ = 0.19). Conclusion: DWI images acquired using the 50‑channel pelvic coil and reconstructed with the DLPC + ARDL pipeline yield the highest image quality compared to ARDL only pipeline and to all 30-channel coil imaging.

18 February 2026 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PLPatricia Sheu Lan
Patricia Sheu Lan
SHSherry S. Huang
Sherry S. Huang
CBChitresh Bhushan
Chitresh Bhushan
XWXinzeng Wang
Xinzeng Wang
SLSeung‐Kyun Lee
Seung‐Kyun Lee
AZAnte Zhu
Ante Zhu