Purpose The recently introduced inhomogeneous magnetization transfer (ihMT) method has predominantly been applied for imaging the central nervous system. Future applications of ihMT, such as in peripheral nerves and muscles, will involve imaging in the vicinity of adipose tissues. This work aims to systematically investigate the partial volume effect of fat on the ihMT signal and to propose an efficient fat‐separation method that does not interfere with ihMT measurements. Methods First, the influence of fat on ihMT signal was studied using simulations. Next, the ihMT sequence was combined with a multi‐echo Dixon acquisition for fat separation. The sequence was tested in 9 healthy volunteers using a 3T human scanner. The ihMT ratio (ihMTR) values were calculated in regions of interest in the brain and the spinal cord using standard acquisition (no fat saturation), water‐only, in‐phase, and out‐of‐phase reconstructions. The values obtained were compared with a standard fat suppression method, spectral presaturation with inversion recovery. Results Simulations showed variations in the ihMTR values in the presence of fat, depending on the TEs used. The IhMTR values in the brain and spinal cord derived from the water‐only ihMT multi‐echo Dixon images were in good agreement with values from the unsuppressed sequence. The ihMT–spectral presaturation with inversion recovery combination resulted in 24%‐35% lower ihMTR values compared with the standard non‐fat‐suppressed acquisition. Conclusion The presence of fat within a voxel affects the ihMTR calculations. The IhMT multi‐echo Dixon method does not compromise the observable ihMT effect and can potentially be used to remove fat influence in ihMT.
16 September 2025 in European Journal of Radiology
Purpose: To compare image quality and clinical utility of a T2‐weighted (T2W) 3‐dimensional (3D) fast spin echo (FSE) sequence using deep learning reconstruction (DLR) versus conventional reconstruction for rectal magnetic resonance imaging (MRI).Methods: The study included 50 patients with rectal cancer who underwent rectal MRI consecutively between July 7, 2020 and January 20, 2021 using a T2W 3D FSE sequence with DLR and conventional reconstruction. Three radiologists reviewed the two sets of images, scoring overall SNR, motion artifacts, and overall image quality on a 3‐point scale and indicating clinical preference for DLR or conventional reconstruction based on those three criteria as well as image characterization of bowel wall layer definition, tumor invasion of muscularis propria, residual disease, fibrosis, nodal margin, and extramural venous invasion.Results: Image quality was rated as moderate or good for both DLR and conventional reconstruction for most cases. DLR was preferred over conventional reconstruction in all of the categories except for bowel wall layer definition.Conclusion: Both conventional reconstruction and DLR provide acceptable image quality for T2W 3D FSE imaging of rectal cancer. DLR was clinically preferred over conventional reconstruction in almost all categories.
Background: MR diffusion-weighted imaging (DWI), especially at high b-value, is a key acquisition to help identify clinically significant prostate cancer; however, it suffers from low signal-to-noise ratio (SNR), high noise floor, and susceptibility artifact. Purpose: To demonstrate the feasibility of improving DWI quality using a novel 50-channel pelvic coil in conjunction with a deep learning (DL)-based phase correction and a DL-denoising algorithm. Methods: In this prospective, single-center study, 24 consecutive men referred for prostate multiparametric MRI over 16 months were enrolled (age 47–79 years; mean, 68.1 years). Axial T2-weighted images and DWI were obtained using a prototype 50‑channel coil and standard clinical phased array (3 T Architect, GE HealthCare, USA). The DWI acquisitions were reconstructed with the vendor’s deep learning denoising algorithm (ARDL). The same raw data were reconstructed offline using an investigational DL Phase Correction algorithm with ARDL (DLPC+ARDL). Two independent readers scored DWI and ADC series using 4 qualitative criteria. SNR and contrast-to-noise ratio (CNR) were measured on b = 1500 s/mm2 images. Combined reader scores were compared using the Wilcoxon matched‑pairs signed‑rank test, inter‑reader variability was assessed using Cohen’s κ, and quantitative SNR/CNR values were compared using 2‑tailed paired t‑tests. Results: Twenty men were analyzable for qualitative and 18 for quantitative metrics (reported as mean ± SD). 50‑channel pelvic coil with DLPC+ARDL produced the highest SNR (99.70 ± 28.50) and CNR (91.68 ± 44.39), exceeding 50‑channel with ARDL alone (SNR 56.44 ± 28.50; CNR 51.11 ± 28.67), 30‑channel anterior array with ARDL (SNR 31.41 ± 13.18; CNR 26.26 ± 13.52), and DLPC + ARDL (SNR 49.4 ± 18.6; CNR 44.7 ± 18.3) (all P < .0001). Reader scores favored DLPC+ARDL in prostate border definition, peripheral/transition zone distinction, lesion conspicuity, and confidence of extraprostatic extension (all P values for DWI at b = 1500 s/mm2 < 0.0001; synthetic DWI at b = 2000 s/mm2: P = 7.5 × 10−7–0.01). Inter‑reader agreement was fair for acquired DWI (quadratic‑weighted κ = 0.34) and lower for synthetic DWI (κ = 0.19). Conclusion: DWI images acquired using the 50‑channel pelvic coil and reconstructed with the DLPC + ARDL pipeline yield the highest image quality compared to ARDL only pipeline and to all 30-channel coil imaging.
1 July 2026 in Quantitative Imaging in Medicine and Surgery
Background: Diffusion-weighted imaging (DWI) in the female pelvis is degraded by artefacts. The study aimed to evaluate the impact of deep-learning image reconstruction (DLRecon) on the image quality of multiplexed sensitivity encoding (MUSE) DWI in the female pelvis. Methods: Female patients scheduled for pelvic magnetic resonance imaging (MRI) with 2-shot MUSE DWI were prospectively recruited. A subset of patients underwent paired 4-shot MUSE DWI. Images were qualitatively reviewed by two radiologists in terms of overall image quality, artefacts, lesions conspicuity and sharpness using a 5-point scale, with and without DLRecon. Intra-observer and inter-observer agreements were evaluated. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) of normal structures and lesions were quantitatively compared between 2-shot MUSE with and without DLRecon. Statistical analyses were performed using Cohen’s kappa, Wilcoxon signed-rank test and paired-sample t-test with Bonferroni correction. Results: Among the 65 female patients evaluated, 27 malignant lesions and 32 benign lesions were detected, while no pathology was found in 6 patients. DLRecon significantly improved the image quality in all aspects evaluated compared to 2-shot MUSE without DLRecon: overall image quality, artefacts, lesions conspicuity and sharpness (N=65, P<0.001). Furthermore, there was no statistical difference in the image quality between 2-shot MUSE with DLRecon and 4-shot MUSE without DLRecon (N=42, P=0.079–0.225). Inter- and intra-observer agreements were substantial to excellent (κ=0.664–0.815). Both SNR and CNR were increased with DLRecon (P<0.050); while no statistical difference was observed in ADC measurements in gluteus muscle (P=0.194), uterus (P=0.127) and lesions (P=0.414). Conclusions: DLRecon improved image quality of MUSE DWI in the female pelvis by reducing impact of artefacts, improving lesion conspicuity and image sharpness, while increasing SNR and CNR but preserving the stability of ADC quantification.