International spread of the coronavirus SARS-CoV-2 has prompted many MRI scanning facilities to require scan subjects to wear a facial covering (“mask”) during scanning as a precaution against transmission of the virus. Because wearing a mask mixes expired air with the subject's inspired air stream, the concentration of inspired carbon dioxide [CO2] is elevated, resulting in mild hypercapnia. Changes in the inspired gas mixture have been demonstrated to alter R2*-weighted Blood Oxygen Dependent (BOLD) contrast. In this study, we investigate a potential for face masking to alter BOLD contrast during a sensory-motor task designed to activate visual, auditory, and sensorimotor cortices in 8 subjects. We utilize a nasal cannula to supply air to the subject wearing a surgical mask in on-off blocks of 90s to displace expired CO2, while the subject performs the sensory-motor task. While only a small fraction (2.5%) of the sensory-motor task activation is related to nasal air modulation, a 30.0% change in gray matter BOLD signal baseline is found due to air modulation. Repeating the scan with mask removed produces a small subject-specific bias in BOLD baseline signal from nasal air supply, which may be due to cognitive influence of airflow or cannula-induced hypoxia. Measurements with capnography demonstrate wearing a mask induces an average increase in ETCO2 of 7.4%. Altogether, these results demonstrate that wearing a face mask during gradient-echo fMRI can alter BOLD baseline signal but minimally affects task activation.
16 September 2025 in European Journal of Radiology
Background/Objectives: This study compared the image quality of conventional multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE-DWI) and deep learning MUSE-DWI with that of vendor-specific deep learning (DL) reconstruction applied to bladder MRI. Methods: This retrospective study included 57 patients with a visible bladder mass. DWI images were reconstructed using a vendor-provided DL algorithm (AIRTM Recon DL; GE Healthcare)—a CNN-based algorithm that reduces noise and enhances image quality—applied here as a prototype for MUSE-DWI. Two radiologists independently assessed qualitative features using a 4-point scale. For the quantitative analysis, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), signal intensity ratio (SIR), and apparent diffusion coefficient (ADC) of the bladder lesions were recorded by two radiologists. The weighted kappa test and intraclass correlation were used to evaluate the interobserver agreement in the qualitative and quantitative analyses, respectively. Wilcoxon signed-rank test was used to compare the image quality of the two sequences. Results: DL MUSE-DWI demonstrated significantly improved qualitative image quality, with superior sharpness and lesion conspicuity. There were no significant differences in the distortion or artifacts. The qualitative analysis of the images by the two radiologists was in good to excellent agreement (κ ≥ 0.61). Quantitative analysis revealed higher SNR, CNR, and SIR in DL MUSE-DWI than in MUSE-DWI. The ADC values were significantly higher in DL MUSE-DWI. Interobserver agreement was poor (ICC ≤ 0.32) for SNR and CNR and excellent (ICC ≥ 0.85) for SIR and ADC values in both DL MUSE-DWI and MUSE-DWI. Conclusions: DL MUSE-DWI significantly enhanced the image quality in terms of lesion sharpness, conspicuity, SNR, CNR, and SIR, making it a promising tool for clinical imaging.
1 July 2026 in Quantitative Imaging in Medicine and Surgery
Background: Diffusion-weighted imaging (DWI) in the female pelvis is degraded by artefacts. The study aimed to evaluate the impact of deep-learning image reconstruction (DLRecon) on the image quality of multiplexed sensitivity encoding (MUSE) DWI in the female pelvis. Methods: Female patients scheduled for pelvic magnetic resonance imaging (MRI) with 2-shot MUSE DWI were prospectively recruited. A subset of patients underwent paired 4-shot MUSE DWI. Images were qualitatively reviewed by two radiologists in terms of overall image quality, artefacts, lesions conspicuity and sharpness using a 5-point scale, with and without DLRecon. Intra-observer and inter-observer agreements were evaluated. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) of normal structures and lesions were quantitatively compared between 2-shot MUSE with and without DLRecon. Statistical analyses were performed using Cohen’s kappa, Wilcoxon signed-rank test and paired-sample t-test with Bonferroni correction. Results: Among the 65 female patients evaluated, 27 malignant lesions and 32 benign lesions were detected, while no pathology was found in 6 patients. DLRecon significantly improved the image quality in all aspects evaluated compared to 2-shot MUSE without DLRecon: overall image quality, artefacts, lesions conspicuity and sharpness (N=65, P<0.001). Furthermore, there was no statistical difference in the image quality between 2-shot MUSE with DLRecon and 4-shot MUSE without DLRecon (N=42, P=0.079–0.225). Inter- and intra-observer agreements were substantial to excellent (κ=0.664–0.815). Both SNR and CNR were increased with DLRecon (P<0.050); while no statistical difference was observed in ADC measurements in gluteus muscle (P=0.194), uterus (P=0.127) and lesions (P=0.414). Conclusions: DLRecon improved image quality of MUSE DWI in the female pelvis by reducing impact of artefacts, improving lesion conspicuity and image sharpness, while increasing SNR and CNR but preserving the stability of ADC quantification.
18 February 2026 in Magnetic Resonance in Medicine