Abdul Jabbar

Abdul Jabbar

Auto-generated profile, based on publicly available information

Abdul Jabbar

Monash University

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2008 in Canadian Journal of Civil Engineering
Verified
Journal Article
Closed access
ANAmjad Naseer
Amjad Naseer
AJAbdul Jabbar
Abdul Jabbar
AKAkhtar Naeem Khan
Akhtar Naeem Khan
QAQaisar Ali
Qaisar Ali
ZHZakir Hussain
Zakir Hussain
JMJahangir Mirza
Jahangir Mirza
Two Pakistani volcanic ashes, VA1 (as is and calcined) and VA2 (as is), were incorporated into mortar cubes, concrete cylinders, and concrete beams as a partial substitute for ordinary Portland cement (OPC), and were studied in detail. The X-ray diffraction patterns showed that both ashes possessed crystalline as well as amorphous phases. The pozzolanic activity index (PAI) of VA1 at 7 d was below 75%, whereas it was 80% at 28 d. The pozzolonic activity indices in OPC mortars containing VA2 were much higher than those for VA1, both at 7 and 28 d. In mortar cubes and concrete cylinders, approximately the same compressive strengths were observed in samples containing 100% cement as in those incorporating a 10% replacement of cement by either VA1 or VA2. Mortar cubes soaked in 5% sodium sulphate solution demonstrated consistently improved resistances to sulphate attack as ash content increased in the mortar. Similar results were also observed in water absorption tests. Modulus of rupture of all concrete beams decreased as the levels of VA1 and VA2 increased from 10% of OPC content to 40%. Rupture moduli were higher for VA1 than for VA2 at all cement replacement levels.

9 September 2025 in Computers in Biology and Medicine
Verified
Journal Article
Open access
AJAbdul Jabbar
Abdul Jabbar
EGEthan Grooby
Ethan Grooby
YPYang Yi Poh
Yang Yi Poh
KAKhawza I. Ahmad
Khawza I. Ahmad
Md. HassanuzzamanMd. Hassanuzzaman
Md. Hassanuzzaman
FMFaezeh Marzbanrad
Faezeh Marzbanrad
Congenital heart disease (CHD) is the most common type of birth defect, impacting about 1% of live births worldwide. Echocardiography, the gold-standard diagnostic method, is costly and inaccessible in low-resource settings. Diagnosis is delayed due to limited skilled experts, whose ability to interpret pathological patterns varies significantly, causing inter- and intra-clinician variability. Therefore, we present a new method for a more accessible diagnostic modality, the digital stethoscope, to detect CHDs. Our method is based on deep feature fusion, integrating deep and handcrafted features for the automated early detection of CHDs. For this work, Phonocardiography (PCG) recordings were obtained from 751 pediatric subjects (Age:1 month- 16 years) in Bangladesh, ranging from infants to adults at four auscultation locations: mitral valve (MV), aortic valve (AV), pulmonary valve (PV), and tricuspid valve (TV). These recordings were labeled based on confirmed diagnoses by cardiologists as either cases of CHD or non-CHD. The results demonstrated that our proposed model achieved an accuracy of 92%, a sensitivity of 91%, and a specificity of 91%, based on a patient-wise split of 70% training, 20% validation, and 10% testing. Furthermore, the Area Under the Receiver Operating Characteristic curve (AUROC) of 96%, and an F1-score of 92%. This model promises efficient real-time remote detection of CHDs as a cost-effective screening tool for low-resource settings.

10 December 2022 in Journal of Neuroimaging
Verified
Journal Article
Closed access
BRBradley M. Ritland
Bradley M. Ritland
WNWilliam H. Neumeier
William H. Neumeier
SJSam H. Jiang
Sam H. Jiang
CSCarl D. Smith
Carl D. Smith
KHKristin J. Heaton
Kristin J. Heaton
ALAlexander P. Lin
Alexander P. Lin

12 June 2023 in International journal of Engineering Works
Verified
Journal Article
Open access
PDF file
AJAbdul Jabbar
Abdul Jabbar
MKM. Irfan Khtaak
M. Irfan Khtaak
AUArif Ullah
Arif Ullah
Using Computer Tomographic (CT) Images, A Rebust Hybrid Computer-Aided Deep Learning Framework for Lung Cancer Classification

14 August 2018 in Acta Geophysica
Verified
Journal Article
Closed access
PDF file
AKAbdul Razzaq Khan
Abdul Razzaq Khan
AMAdil Aslam Aslam Mir
Adil Aslam Aslam Mir
SSSharjil Saeed
Sharjil Saeed
MRMuhammad Rafique
Muhammad Rafique
KAKhawaja M. Asim
Khawaja M. Asim
SRSaeed Ur Rahman
Saeed Ur Rahman

1 January 2026 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
AJAbdul Jabbar
Abdul Jabbar
MHMd Hassanuzzaman
Md Hassanuzzaman
KAKhawza I Ahmad
Khawza I Ahmad
RMRAQIBUL MOSTAFA
RAQIBUL MOSTAFA
AKAhsan Khandoker
Ahsan Khandoker
FMFaezeh Marzbanrad
Faezeh Marzbanrad
Congenital heart disease (CHD) is the most common birth defect and a major cause of infant morbidity and mortality worldwide. While echocardiography remains the diagnostic gold standard, its cost and reliance on expert interpretation limit availability in low- and middle-income countries (LMICs). This underscores the need for scalable, affordable, and robust approaches that can operate reliably under real-world signal degradation and low-quality recording conditions. In this study, we present a multimodal framework for pediatric CHD detection that integrates phonocardiograms (PCG), electrocardiograms (ECG), and clinical symptoms. Features from PCG and ECG were extracted using a pretrained foundation audio model, while key symptoms were selected using SHAP (SHapley Additive exPlanations) and encoded as structured embeddings. These modalities were combined in a fusion network with modality dropout to handle missing inputs, and mutual learning was applied to promote knowledge sharing across unimodal and multimodal branches. The framework was validated on a dataset of 751 pediatric patients in Bangladesh, comprising 3,435 synchronized PCG-ECG recordings with expert-confirmed labels. In 10-fold patient-wise cross validation, PCG alone achieved 90% accuracy, ECG alone 79%, and symptoms alone 73%. Combining PCG and ECG improved accuracy to 94%, while the full multimodal system reached 94.5% accuracy, 94.2% sensitivity, 95.6% specificity, and an AUROC of 96%. Importantly, even under degraded signal conditions when both PCG and ECG were of low quality, the multimodal framework maintained an accuracy of 88% and an AUROC of 87%, demonstrating superior performance compared to the unimodal models. These findings demonstrate that integrating PCG, ECG, and symptoms enables accurate, resilient CHD screening, offering a practical pathway for scalable early detection in LMICs.