1 February 2020 in Review of Scientific Instruments
The Charge Exchange Recombination Spectroscopy (CXRS) diagnostic has become a routine diagnostic on almost all major high temperature fusion experimental devices. For the optimized stellarator Wendelstein 7-X (W7-X), a highly flexible and extensive CXRS diagnostic has been built to provide high-resolution local measurements of several important plasma parameters using the recently commissioned neutral beam heating. This paper outlines the design specifics of the W7-X CXRS system and gives examples of the initial results obtained, including typical ion temperature profiles for several common heating scenarios, toroidal flow and radial electric field derived from velocity measurements, beam attenuation via beam emission spectra, and normalized impurity density profiles under some typical plasma conditions.
16 March 2023 in Nuclear Fusion
In this work, we provide the first 2D spatially resolved description of radiative detachment in MAST-U Super-X L-mode divertor plasmas. The Super-X magnetic configuration was designed to achieve reduced heat- and particle loads at the divertor target compared to conventional exhaust solutions. We use filtered camera imaging to reconstruct 2D emissivity profiles in the poloidal plane for multiple atomic and molecular emission lines and bands. A set of deuterium fuelling scans is discussed that, together, span attached to deeply detached divertor states observed in MAST-U. Emissivity profiles facilitate separate analysis of locked-mode induced split branches of the scrape-off layer. Molecular deuterium Fulcher band emission front tracking reveals that the deuterium electron-impact ionisation front, for which it serves a proxy, detaches at different upstream electron densities in the split branches. Upon detachment of this ionisation front, Balmer emission attributed to molecular activated recombination appears near-target. We report a simultaneous radial broadening of the emission leg, consistent with previous SOLPS-ITER modelling. With increased fuelling this emission region detaches, implying electron temperatures below eV. In this phase, 2D Balmer line ratio reconstruction indicates an onset of volumetric direct electron-ion recombination near-target. At the highest fuelling rates this emission region moves off-target, suggesting a drop in near-wall electron density accompanying the low temperatures.
10 September 2004 in Nuclear Fusion
8 June 2023 in Nuclear Fusion
Radial impurity density profiles in two Wendelstein 7-X (W7-X) experiments heated by neutral beam injection (NBI) are analyzed with respect to their impurity transport properties. Local impurity densities are derived from charge exchange reactions with the W7-X NBI system using simulated neutral densities cross-validated with beam emission spectroscopy. Impurity profiles of argon and carbon are found to show an evolving central accumulation inside half radius. The properties of the underlying impurity transport are assessed using the one-dimensional transport code pySTRAHL. Comparisons between simulation and experiment indicate transport dominated by anomalous diffusion outside half radius. The observed central impurity accumulation is found to match best simulations with purely (neo-)classical transport in the accumulation region. This data implies a suppression of the anomalous impurity transport channel to below 35% of the (neo-)classical one. Experimental data is found to be matched best when invoking a time evolving, inward propagating zone where anomalous impurity transport is suppressed. An additional central power deposition into a plasma with central impurity accumulation via electron cyclotron resonance heating is found to affect the (neo-)classical transport components in case of operation times below 200 ms only. For longer operation times, it is found to re-introduce an altered level of anomalous diffusion. The existence of an inward directed anomalous pinch as an alternative explanation for the central impurity accumulation cannot explain the observed profiles.
16 July 2012 in Review of Scientific Instruments
A feasibility study for the use of core charge exchange recombination spectroscopy on ITER has shown that accurate measurements on the helium ash require a spectrometer with a high etendue of 1mm2sr to comply with the measurement requirements [S. Tugarinov et al., Rev. Sci. Instrum. 74, 2075 (2003)]10.1063/1.1537443. To this purpose such an instrument has been developed consisting of three separate wavelength channels (to measure simultaneously He/Be, C/Ne, and H/D/T together with the Doppler shifted direct emission of the diagnostic neutral beam, the beam emission (BES) signal), combining high dispersion (0.02 nm/pixel), sufficient resolution (0.2 nm), high efficiency (55%), and extended wavelength range (14 nm) at high etendue. The combined measurement of the BES along the same sightline within a third wavelength range provides the possibility for in situ calibration of the charge eXchange recombination spectroscopy signals. In addition, the option is included to use the same instrument for measurements of the fast fluctuations of the beam emission intensity up to 2 MHz, with the aim to study MHD activity.
1 October 2008 in Review of Scientific Instruments
The charge exchange recombination spectroscopy system (CXRS) for ITER is designed to measure the core helium concentration, and in addition, profiles of ion temperature and rotation. This highly demanding task, due to the huge background radiation (bremsstrahlung) and the high attenuation of the dedicated diagnostic neutral beam, requires high throughput spectrometers with high resolution. On TEXTOR, a CXRS system has been developed with the aim to test the physics implications of these specifications. (i) A relevant spectrometer has been tested. (ii) A method to determine the helium concentrations from the CXRS intensity, using the beam emission has been evaluated. A 20% discrepancy in beam emission was revealed. (iii) The determination of the magnetic pitch angle by the ratio of Balmer lines showed qualitatively the right behavior, although the accuracy was limited by the polarization sensitivity of the first mirror. (iv) The simulation code developed for the prediction of the CXRS spectra was quantitatively confronted with experimental data.