16 December 2022 in Nuclear Fusion
We present the first analysis of the atomic and molecular processes at play during detachment in the MAST-U Super-X divertor using divertor spectroscopy data. Our analysis indicates detachment in the MAST-U Super-X divertor can be separated into four sequential phases: first, the ionisation region detaches from the target at detachment onset leaving a region of increased molecular densities downstream. The plasma interacts with these molecules, resulting in molecular ions ( and/or ) that further react with the plasma leading to molecular activated recombination and dissociation (MAR and MAD), which results in excited atoms and significant Balmer line emission. Second, the MAR region detaches from the target leaving a sub-eV temperature region downstream. Third, an onset of strong emission from electron–ion recombination (EIR) ensues. Finally, the electron density decays near the target, resulting in the bulk of the electron density moving upstream. The analysis in this paper indicates that plasma–molecule interactions have a larger impact than previously reported and play a critical role in the intensity and interpretation of hydrogen atomic line emission characteristics on MAST-U. Furthermore, we find that the Fulcher band emission profile in the divertor can be used as a proxy for the ionisation region and may also be employed as a plasma temperature diagnostic for improving the separation of hydrogenic emission arising from electron-impact excitation and that from plasma–molecular interactions. We provide evidences for the presence of low electron temperatures (≪0.5 eV) during detachment phases III–IV based on quantitative spectroscopy analysis, a Boltzmann relation of the high-n Balmer line transitions together with an analysis of the brightness of high-n Balmer lines.
16 March 2023 in Nuclear Fusion
In this work, we provide the first 2D spatially resolved description of radiative detachment in MAST-U Super-X L-mode divertor plasmas. The Super-X magnetic configuration was designed to achieve reduced heat- and particle loads at the divertor target compared to conventional exhaust solutions. We use filtered camera imaging to reconstruct 2D emissivity profiles in the poloidal plane for multiple atomic and molecular emission lines and bands. A set of deuterium fuelling scans is discussed that, together, span attached to deeply detached divertor states observed in MAST-U. Emissivity profiles facilitate separate analysis of locked-mode induced split branches of the scrape-off layer. Molecular deuterium Fulcher band emission front tracking reveals that the deuterium electron-impact ionisation front, for which it serves a proxy, detaches at different upstream electron densities in the split branches. Upon detachment of this ionisation front, Balmer emission attributed to molecular activated recombination appears near-target. We report a simultaneous radial broadening of the emission leg, consistent with previous SOLPS-ITER modelling. With increased fuelling this emission region detaches, implying electron temperatures below eV. In this phase, 2D Balmer line ratio reconstruction indicates an onset of volumetric direct electron-ion recombination near-target. At the highest fuelling rates this emission region moves off-target, suggesting a drop in near-wall electron density accompanying the low temperatures.
30 January 2023 in Nuclear Materials and Energy
4 October 2023 in Nuclear Fusion
This paper shows first quantitative analysis of the detachment processes in the MAST Upgrade Super-X divertor (SXD). We identify an unprecedented impact of plasma-molecular interactions involving molecular ions (likely ), resulting in strong ion sinks (Molecular Activated Recombination—MAR), leading to a reduction of ion target flux. The MAR ion sinks exceed the divertor ion sources before electron-ion recombination (EIR) starts to occur, suggesting that significant ionisation occurs outside of the divertor chamber. In the EIR region, eV is observed and MAR remains significant in these deep detached phases. The total ion sink strength demonstrates the capability for particle (ion) exhaust in the Super-X Configuration. Molecular Activated Dissociation is the dominant volumetric neutral atom creation process can lead to an electron cooling of 20% of . The measured total radiative power losses in the divertor chamber are consistent with inferred hydrogenic radiative power losses. This suggests that intrinsic divertor impurity radiation, despite the carbon walls, is minor in the divertor chamber. This contrasts previous TCV results, which may be associated with enhanced plasma-neutral interactions and reduced chemical erosion in the detached, tightly baffled SXD. The above observations have also been observed in higher heat flux (narrower SOL width) type I ELMy H-mode discharges. This provides evidence that the characterisation in this paper may be general.
29 August 2024 in Nuclear Fusion
Recent results from MAST Upgrade are presented, emphasising understanding the capabilities of this new device and deepening understanding of key physics issues for the operation of ITER and the design of future fusion power plants. The impact of MHD instabilities on fast ion confinement have been studied, including the first observation of fast ion losses correlated with Compressional and Global Alfvén Eigenmodes. High-performance plasma scenarios have been developed by tailoring the early plasma current ramp phase to avoid internal reconnection events, resulting in a more monotonic q profile with low central shear. The impact of m/n = 3/2, 2/1 and 1/1 modes on thermal plasma confinement and rotation profiles has been quantified, and scenarios optimised to avoid them have transiently reached values of normalised beta approaching 4.2. In pedestal and ELM physics, a maximum pedestal top temperature of ∼350 eV has been achieved, exceeding the value achieved on MAST at similar heating power. Mitigation of type-I ELMs with n = 1 RMPs has been observed. Studies of plasma exhaust have concentrated on comparing conventional and Super-X divertor configurations, while X-point target, X-divertor and snowflake configurations have been developed and studied in parallel. In L-mode discharges, the separatrix density required to detach the outer divertors is approximately a factor 2 lower in the Super-X than the conventional configuration, in agreement with simulations. Detailed analysis of spectroscopy data from studies of the Super-X configuration reveal the importance of including plasma-molecule interactions and D2 Fulcher band emission to properly quantify the rates of ionisation, plasma-molecule interactions and volumetric recombination processes governing divertor detachment. In H-mode with conventional and Super-X configurations, the outer divertors are attached in the former and detached in the latter with no impact on core or pedestal confinement.
4 July 2024 in Nuclear Fusion
This experimental study presents an in-depth investigation of the performance of the MAST-U Super-X divertor during NBI-heated operation (up to 2.5 MW) focussing on volumetric ion sources and sinks as well as power losses during detachment. The particle balance and power loss analysis revealed the crucial role of Molecular Activated Recombination and Dissociation (MAR and MAD) ion sinks in divertor particle and power balance, which remain pronounced in the change from ohmic to higher power (NBI heated) L-mode conditions. The importance of MAR and MAD remains with double the absorbed NBI heating. MAD results in significant power dissipation (up to of ), mostly in the cold ( eV) detached region. Theoretical and experimental evidence is found for the potential contribution of to MAR and MAD, which warrants further study. These results suggest that MAR and MAD can be relevant in higher power conditions than the ohmic conditions studied previously. Post-processing reactor-scale simulations suggests that MAR and MAD can play a significant role in divertor physics and synthetic diagnostic signals of reactor-scale devices, which are currently underestimated in exhaust simulations. This raises implications for the accuracy of reactor-scale divertor simulations of particularly tightly baffled (alternative) divertor configurations.