16 March 2023 in Nuclear Fusion
In this work, we provide the first 2D spatially resolved description of radiative detachment in MAST-U Super-X L-mode divertor plasmas. The Super-X magnetic configuration was designed to achieve reduced heat- and particle loads at the divertor target compared to conventional exhaust solutions. We use filtered camera imaging to reconstruct 2D emissivity profiles in the poloidal plane for multiple atomic and molecular emission lines and bands. A set of deuterium fuelling scans is discussed that, together, span attached to deeply detached divertor states observed in MAST-U. Emissivity profiles facilitate separate analysis of locked-mode induced split branches of the scrape-off layer. Molecular deuterium Fulcher band emission front tracking reveals that the deuterium electron-impact ionisation front, for which it serves a proxy, detaches at different upstream electron densities in the split branches. Upon detachment of this ionisation front, Balmer emission attributed to molecular activated recombination appears near-target. We report a simultaneous radial broadening of the emission leg, consistent with previous SOLPS-ITER modelling. With increased fuelling this emission region detaches, implying electron temperatures below eV. In this phase, 2D Balmer line ratio reconstruction indicates an onset of volumetric direct electron-ion recombination near-target. At the highest fuelling rates this emission region moves off-target, suggesting a drop in near-wall electron density accompanying the low temperatures.
1 June 2021 in Review of Scientific Instruments
Divertor detachment and alternative divertor magnetic geometries are predicted to be promising approaches to handle the power exhaust of future fusion devices. In order to understand the detachment process caused by volumetric losses in alternative divertor magnetic geometries, a Multi-Wavelength Imaging (MWI) diagnostic has recently been designed and built for the Mega Amp Spherical Tokamak Upgrade. The MWI diagnostic will simultaneously capture 11 spectrally filtered images of the visible light emitted from divertor plasmas and provide crucial knowledge for the interpretation of observations and modeling efforts. This paper presents the optical design, mechanical design, hardware, and test results of an 11-channel MWI system with a field of view of 40°. The optical design shows better than 5 mm FWHM spatial resolution at the plasma on all 11 channels across the whole field of view. The spread of angle of incidence on the surface of each filter is also analyzed to inform the bandwidth specification of the interference filters. The results of the initial laboratory tests demonstrate that a spatial resolution of better than 5 mm FWHM is achieved for all 11 channels, meeting the specifications required for accurate tomography.
1 July 2021 in Review of Scientific Instruments
In this paper, the pixelated phase mask (PPM) method of interferometry is applied to coherence imaging (CI)—a passive, narrowband spectral imaging technique for diagnosing the edge and divertor regions of fusion plasma experiments. Compared to previous CI designs that use a linear phase mask, the PPM method allows for a higher possible spatial resolution. The PPM method is also observed to give a higher instrument contrast (analogous to a more narrow spectrometer instrument function). A single-delay PPM instrument is introduced as well as a multi-delay system that uses a combination of both pixelated and linear phase masks to encode the coherence of the observed radiation at four different interferometer delays simultaneously. The new methods are demonstrated with measurements of electron density ne, via Stark broadening of the Hγ emission line at 434.0 nm, made on the Magnum-PSI linear plasma experiment. A comparison of the Abel-inverted multi-delay CI measurements with Thomson scattering shows agreement across the 3 × 1019 < ne < 1 × 1021 m−3 range. For the single-delay CI results, agreement is found for ne > 1 × 1020 m−3 only. Accurate and independent interpretation of single-delay CI data at lower ne was not possible due to Doppler broadening and continuum emission.
5 February 2025 in Plasma Physics and Controlled Fusion
TTthe EUROfusion Tokamak Exploitation Team
the EUROfusion Tokamak Exploitation Team
+8
2D profiles of electron density and neutral temperature are inferred from multi-delay coherence imaging spectroscopy data of divertor plasmas using a non-linear inversion technique. The inference is based on imaging the spectral line-broadening of Balmer lines and can differentiate between the Doppler and Stark broadening components by measuring the fringe contrast at multiple interferometric delays simultaneously. The model has been applied to images generated from simulated density profiles to evaluate its performance. Typical mean absolute errors of 30% are achieved, which are consistent with Monte Carlo uncertainty propagation accounting for noise, uncertainties in the calibrations, and in the model inputs. The analysis has been tested on experimental data from the MAST-U Super-X divertor, where it infers typical electron densities of 2–3 1019 m−3 and neutral temperatures of 0–2 eV during beam-heated L-mode discharges. The results are shown to be in reasonable agreement with the other available diagnostics.
1 May 2024 in Review of Scientific Instruments
The MAST-U Super-X divertor provides the opportunity to study fusion plasma exhaust under novel conditions. However, in order to study these conditions, advanced diagnostics are required. Following the development of the MAST-U Multi-Wavelength Imaging (MWI) diagnostic, we present the installation of a multi-delay coherence imaging spectroscopy (CIS) system within the MAST-U MWI, along with modifications made to the MWI for effective operation. This diagnostic will measure either carbon ion flow velocities and temperatures or electron densities through Dγ emission. We have extended previously developed techniques for wavelength calibration to account for errors due to the misalignment of interferometer components. In addition, we have developed a comprehensive calibration procedure to account for the temperature dependence of the instrument’s delays by fitting to a linearly modified version of the delay equation presented by Veiras et al. [Appl. Opt. 49(15), 2769 (2010)]. Together, these procedures reduce the cost and hardware complexity of implementing CIS instruments when compared to those that use in situ or tunable laser calibration systems, as calibrations can be generated to good accuracy using previously measured data.
13 October 2025 in Nuclear Fusion
The improved performance of the long-legged alternative divertor configurations on MAST-U, combining strong baffling and total flux expansion, results in stronger power and momentum losses. These lead to lower electron temperatures and peak particle fluxes at the target compared to conventional divertor configurations. The evolution of the divertor electron density profile in the detached region, measured via coherence imaging spectroscopy, is characterized by a density peak building up near the target, downstream of the detachment front, with increasing upstream density. The peak then moves upstream from the target as the target temperature decreases ( eV). This behaviour is in agreement with simplified modelling based on the competition of different ion recombination processes and neutral drag acting on the plasma flow. Comparisons against SOLPS-ITER simulations generally show good agreement in the magnitude of the electron density profiles, both along and across the separatrix, but with some discrepancies in the shape of the profiles in the private flux region and near the target.