Muhammad Sufyan

Muhammad Sufyan

Auto-generated profile, based on publicly available information

Muhammad Sufyan

Department of Electrical Engineering, Main Campus, Iqra University, Karachi 75300, Pakistan

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MSMuhammad Sufyan
Muhammad Sufyan
NRNasrudin Abd Rahim
Nasrudin Abd Rahim
CTChiaKwang Tan
ChiaKwang Tan
MMMunir Azam Software & Muhammad
Munir Azam Software & Muhammad
SRSiti Rohani Sheikh Raihan
Siti Rohani Sheikh Raihan
The incessantly growing demand for electricity in today’s world claims an efficient and reliable system of energy supply. Distributed energy resources such as diesel generators, wind energy and solar energy can be combined within a microgrid to provide energy to the consumers in a sustainable manner. In order to ensure more reliable and economical energy supply, battery storage system is integrated within the microgrid. In this article, operating cost of isolated microgrid is reduced by economic scheduling considering the optimal size of the battery. However, deep discharge shortens the lifetime of battery operation. Therefore, the real time battery operation cost is modeled considering the depth of discharge at each time interval. Moreover, the proposed economic scheduling with battery sizing is optimized using firefly algorithm (FA). The efficacy of FA is compared with other metaheuristic techniques in terms of performance measurement indices, which are cost of electricity and loss of power supply probability. The results show that the proposed technique reduces the cost of microgrid and attain optimal size of the battery.

1 January 2019 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
MSM. Sufyan
M. Sufyan
NRNasrudin Abd Rahim
Nasrudin Abd Rahim
MAM. M. Aman
M. M. Aman
CTC. K. Tan
C. K. Tan
SRSiti Rohani Sheikh Raihan
Siti Rohani Sheikh Raihan
Dynamics of the world are changing, and people are preferring low cost and reliable power throughout the day. The addition of renewable energy to the existing system is also one of the ways to provide reliable and cheap electricity. The existing bottle neck in transmission lines, continuous contamination of the environment due to heavy reliance on fossil fuels, and the highly fluctuating cost of fossil fuel are few reasons for the widespread use of renewable energy technology. Energy storage technologies are the need of time and range from low capacity mobile storage batteries to high capacity batteries connected to the intermittent renewable energy sources. Selection of different battery types, each having distinguished characteristics in power and energy, depends on the nature of power required and delivered. This paper presents a detailed review of battery energy storage technologies pertaining to the latest technologies, benefits, sizing considerations, efficiency, cost, and recycling. An in-depth analysis in terms of advantages and limitations between the different types of batteries is discussed and compared. In terms of microgrid application, the economic benefits of battery sizing using optimization and probabilistic methods provide a potential solution during the design stage by taking into account various factors affecting the sizing of the battery such as the degradation rate, reliability, and battery placement. This paper ends with the discussion on the recyclability of these batteries and their impact on the environment.

1 July 2020 in Electric Power Systems Research
Verified
Journal Article
Closed access
MSM. Sufyan
M. Sufyan
NRNasrudin Abd Rahim
Nasrudin Abd Rahim
MMMunir Azam Software & Muhammad
Munir Azam Software & Muhammad
CTC.K. Tan
C.K. Tan
SRSiti Rohani Sheikh Raihan
Siti Rohani Sheikh Raihan
ABA.H.A. Bakar
A.H.A. Bakar

1 April 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
HMHamza Mubarak
Hamza Mubarak
MMMunir Azam Software & Muhammad
Munir Azam Software & Muhammad
NMNurulafiqah Nadzirah Mansor
Nurulafiqah Nadzirah Mansor
Hazlie MokhlisHazlie Mokhlis
Hazlie Mokhlis
SAShameem Ahmad
Shameem Ahmad
MSMuhammad Sufyan
Muhammad Sufyan
Continuous increases in electrical energy demand and the deregulation of power systems have forced utility companies to provide high-quality and reliable services to maintain a sustainable operation and reduce electricity price. One way to continue providing the required services while simultaneously reducing operational costs is through minimizing power losses and voltage deviation in the distribution network. For this purpose, Network Reconfiguration (NR) is commonly adopted by employing the switching operation to enhance overall system performance. In the past, work proposed by researchers to attain switching sequence operation was based on hamming distance approach. This approach caused the search space to grow with the increase in total Hamming distance between the initial and the final configuration. Therefore, a method is proposed in this paper utilizing a Mixed Integer Second Order Cone Programming (MISOCP) to attain optimal NR to address this issue. The Hamming dataset approach is opted to reduce search space by considering only radial configuration solutions to achieve an optimal switching sequence. In addition, a detailed economic analysis has been performed to determine the saving after the implementation of the proposed switching sequence. The effectiveness of the proposed technique is validated through simulations on IEEE 33-bus distribution network and a practical 71-bus network in Malaysia. The result shows that the proposed method determined the optimal network configuration by minimizing the power losses for the 33 bus and 71-bus system by 34.14% and 25.5% from their initial configuration, respectively to maintain sustainable operation.

1 July 2019 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
MSM. Sufyan
M. Sufyan
NRNasrudin Abd Rahim
Nasrudin Abd Rahim
BEBilal Eid
Bilal Eid
SRSiti Rohani Sheikh Raihan
Siti Rohani Sheikh Raihan
Photovoltaic (PV) sources have recently become one of the most mature technologies. With the increasing penetration level and the integration of a PV system into the grid, the stability and reliability of the power networks have been serious concerns. Thus, grid codes are being released by grid operators for low voltage networks under grid faults. Consequently, the Low Voltage Ride Through (LVRT) capability of the grid connected PV system became the most important issue related to grid codes, i.e., more reactive power is injected into the grid during voltage disturbances. In this paper, a comprehensive review of reactive power control strategies for the three-phase PV system has been analyzed to support the grid during voltage sags by providing LVRT capability. The control techniques have been classified into three main categories: Fixed power factor, constant active power control, and constant reactive power control. The results illustrate that the stability of the system is improved when two control techniques are simultaneously implemented. This paper concludes that further research must be carried on LVRT control techniques for the reactive power injection during unbalanced voltage sags.

1 August 2018
Verified
Conference Paper
Closed access
MSMuhammad Sufyan
Muhammad Sufyan
CTChiaKwang Tan
ChiaKwang Tan
NRNasrudin Abd Rahim
Nasrudin Abd Rahim
SRSiti Rohani Shaikh Raihan
Siti Rohani Shaikh Raihan
MMMunir Azam Software & Muhammad
Munir Azam Software & Muhammad
This paper presents a mixed integer quadratic programming to minimize the operation cost of isolated microgrid using diesel generator and energy storage. The deployment of energy storage with the distributed generators is an effective method for storing the energy for utilization during high load periods. The proposed method is applied on a power system with 3 diesel generators and energy storage serving as backup to meet the required load. The cost of microgrid is optimized by optimal dispatch of generators and power discharged by energy storage during peak load periods. The results show that the optimum cost of microgrid is achieved when the diesel generators dispatch the maximum power to load and the energy storage is used only during the peak load periods when the generators capacity is insufficient to fulfil the load demand.