Detection of live microalgae is critical to ballast water treatment. A novel handheld high-throughput ballast water rapid detection device based on microfluidic chip and fluorometry for counting single living microalgae cell is demonstrated in this article. The viability of individual microalgae cells can be evaluated and the number of the living microalgae cells in an aqueous solution sample can be obtained at a rate of one milliliter per minute in a fully automatic and real-time manner. It is experimentally confirmed that the detection results of this device are not influenced by free chlorophyll from the lysed microalgae, nor by the salinity and turbidity of the sample within the variation range of ballast water. Furthermore, this device has been used in a port to test the actual ballast water samples processed by ballast water treatment systems based on different principles or loaded at different locations, and the conclusion of this device on the qualification of the ship is consistent with the conclusion of the laboratory standard test. To the best of our knowledge, this is the first ballast water rapid detection device using a microfluidic chip as the detection platform, which can be used on board of ships for on-site counting the numbers of the living microalgae cells in ballast water.
On-site rapid detection of cells is especially of concern for many fields, image-based detection results can directly reflect the multi-dimensional information such as cell contour and aggregation state. This article proposes an innovative miniaturized cell imaging system based on integrated coaxial dual optical path structure and microfluidic fixed frequency sample loading strategy, which performs synchronous imaging of bright field mode and fluorescence field mode on cells. The bright field optical path and fluorescence field optical path are integrated into the coaxial dual optical path structure based on the dichroic mirror with splitting and steering functions. The movement of the shutter’s curtain is controlled by a micro-motor, so that the plane mirrors fixed on the curtain with different light angle can be switched to the optical axis, and the fast switching of the bright field optical path and the fluorescence field optical path can be implemented. A drawer-type filter module can be pulled out of the coaxial dual optical path structure, the emission filter and the dichroic mirror in this module can be replaced according to the fluorescence emission peak of the sample to be tested, thereby expanding the detectable cell types of this system. In addition, based on the force analysis and calculation of the fluid, a fixed frequency was obtained to drive the sample loading. The accumulated kinetic energy of the fluid during this period can be offset by the closing of the pinch valve, and the flow rate of the sample in the imaging field can be rapidly reduced to close to zero to avoid the tailing effect in the image. It is experimentally confirmed that the detection accuracy of this system, the registration matching accuracy of cells and fluorescent dots, the cell survival rate, and the detection sensitivity of cell viability. This system balances the tradeoff between portability, flux and accuracy, offers more functionality in terms of technology and application for on-site cell detection.