On-site rapid detection of cells is especially of concern for many fields, image-based detection results can directly reflect the multi-dimensional information such as cell contour and aggregation state. This article proposes an innovative miniaturized cell imaging system based on integrated coaxial dual optical path structure and microfluidic fixed frequency sample loading strategy, which performs synchronous imaging of bright field mode and fluorescence field mode on cells. The bright field optical path and fluorescence field optical path are integrated into the coaxial dual optical path structure based on the dichroic mirror with splitting and steering functions. The movement of the shutter’s curtain is controlled by a micro-motor, so that the plane mirrors fixed on the curtain with different light angle can be switched to the optical axis, and the fast switching of the bright field optical path and the fluorescence field optical path can be implemented. A drawer-type filter module can be pulled out of the coaxial dual optical path structure, the emission filter and the dichroic mirror in this module can be replaced according to the fluorescence emission peak of the sample to be tested, thereby expanding the detectable cell types of this system. In addition, based on the force analysis and calculation of the fluid, a fixed frequency was obtained to drive the sample loading. The accumulated kinetic energy of the fluid during this period can be offset by the closing of the pinch valve, and the flow rate of the sample in the imaging field can be rapidly reduced to close to zero to avoid the tailing effect in the image. It is experimentally confirmed that the detection accuracy of this system, the registration matching accuracy of cells and fluorescent dots, the cell survival rate, and the detection sensitivity of cell viability. This system balances the tradeoff between portability, flux and accuracy, offers more functionality in terms of technology and application for on-site cell detection.
The ocean, a blue dreamland, harbors endless romance, and mystery. Microfluidic technology, as an innovative approach, enables precise control and manipulation of microscale fluids by regulating the flow patterns and structures within micrometer-sized channels. It offers a new perspective and solutions for microbiological analysis. This paper presents a comprehensive review of microfluidic chip technology in the field of marine microbiological analysis, encompassing micro-organism capture, isolation and enrichment, microbial cultivation, fluorescence detection techniques, single-cell microfluidic impedance cytometry, polymerase chain reaction amplification, gene sequencing technologies, and the application of microfluidic technology in marine microbial sensing. The challenges currently faced and future prospects are also discussed. We believe this review will promote research in microfluidics within the microbial domain, providing valuable insights for researchers in this field.
We report a 31.2 W cw diode-pumped cryogenic Ho(0.4at.%),Tm(4at.%):GdVO4 laser in a dual-crystal cavity. The pumping sources are two fiber-coupled laser diodes with a fiber core diameter of 0.4 mm, both of which can supply 42 W near 802 nm. With an incident pump power of 70.3 W at 802.4 nm, a cw output power of 31.2 W at 2.05 μm is attained, corresponding to an optical-to-optical conversion efficiency of 44.4%. The M2 factor is measured as ~1.3 under an output power of 20 W.
15 July 2025 in IEEE Transactions on Instrumentation and Measurement
Conventional electrochemical methods, improved for selectivity and sensitivity through the application of ion-selective membranes or electrode modifications, were complex to produce and prone to interference from other ions, lacking effective mitigation strategies. Therefore, a simple, accurate, and selective detection method for nickel ions based on a microfluidic electrochemical sensor was developed. The microfluidic electrochemical sensor incorporated a bare carbon electrode. The microfluidic technology was employed to control the sequential mixing of samples, masking agents, and chelating agents, achieving automated sample preprocessing within 1 min, faster than the conventional electrode modification process. The hybrid microchannel was designed to enhance the effectiveness of mixing between the sample and the masking agent, resulting in increasing the masking effect on interfering ions. Based on the high affinity of the masking agent for interfering ions, the interference ions were effectively masked, ensuring that only nickel ions reacted with the complexing agent. Tests using pure nickel solutions revealed that the microfluidic electrochemical sensor possessed excellent properties of linear detection range and resolution. Compared to conventional modified electrodes, the microfluidic electrochemical sensor simplified fabrication, exhibited good reproducibility and repeatability, and achieved higher selectivity. The experiments on anti-interference performance demonstrated that the masking agent effectively shielded against interfering ions, the Bias% after the mask was less than 3%. The practical tests using real water samples proved the effectiveness and suitability of this detection method in specifically identifying heavy metal ions.
25 April 2012 in Acta Crystallographica Section E Crystallographic Communications
In the title compound, [Ce(C(9)H(4)N(2)O(4))(C(2)H(3)O(2))(H(2)O)](n), the Ce(III) ion is coordinated by five O atoms and one N atom from four 1H-benzimidazole-5,6-dicarboxyl-ato (L) ligands and by two O atoms from an acetate ligand and one aqua ligand, forming a slightly distorted tricapped trigonal-prismatic geometry. The L ligands are bridging, forming a layered polymer parallel to (010). In the crystal, O-H⋯O and N-H⋯O hydrogen bonds connect the polymer layers into a three-dimensional network.