Arnold David Gomez

Arnold David Gomez

Auto-generated profile, based on publicly available information

Arnold David Gomez

Johns Hopkins University

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Brain Multiphysics
Verified
Journal Article
Open access
AKAndrew K Knutsen
Andrew K Knutsen
AGArnold D. Gomez
Arnold D. Gomez
MGMihika Gangolli
Mihika Gangolli
WWWen-Tung Wang
Wen-Tung Wang
DCDeva Chan
Deva Chan
DPDzung L. Pham
Dzung L. Pham
The rapid deformation of brain tissue in response to head impact can lead to traumatic brain injury. In vivo measurements of brain deformation during non-injurious head impacts are necessary to understand the underlying mechanisms of traumatic brain injury and compare to computational models of brain biomechanics. Using tagged magnetic resonance imaging (MRI), we obtained measurements of three-dimensional strain tensors that resulted from a mild head impact after neck rotation or neck extension. Measurements of maximum principal strain (MPS) peaked shortly after impact, with maximal values of 0.019–0.053 that correlated strongly with peak angular velocity. Subject-specific patterns of MPS were spatially heterogeneous and consistent across subjects for the same motion, though regions of high deformation differed between motions. The largest MPS values were seen in the cortical gray matter and cerebral white matter for neck rotation and the brainstem and cerebellum for neck extension. Axonal fiber strain (Ef) was estimated by combining the strain tensor with diffusion tensor imaging data. As with MPS, patterns of Ef varied spatially within subjects, were similar across subjects within each motion, and showed group differences between motions. Values were highest and most strongly correlated with peak angular velocity in the corpus callosum for neck rotation and in the brainstem for neck extension. The different patterns of brain deformation between head motions highlight potential areas of greater risk of injury between motions at higher loading conditions. Additionally, these experimental measurements can be directly compared to predictions of generic or subject-specific computational models of traumatic brain injury.

4 July 2017 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
FXFangxu Xing
Fangxu Xing
JWJonghye Woo
Jonghye Woo
AGArnold D. Gomez
Arnold D. Gomez
DPDzung L. Pham
Dzung L. Pham
PBPhilip V. Bayly
Philip V. Bayly
JPJerry L. Prince
Jerry L. Prince
Tagged magnetic resonance imaging has been used for decades to observe and quantify motion and strain of deforming tissue. It is challenging to obtain 3-D motion estimates due to a tradeoff between image slice density and acquisition time. Typically, interpolation methods are used either to combine 2-D motion extracted from sparse slice acquisitions into 3-D motion or to construct a dense volume from sparse acquisitions before image registration methods are applied. This paper proposes a new phase-based 3-D motion estimation technique that first computes harmonic phase volumes from interpolated tagged slices and then matches them using an image registration framework. The approach uses several concepts from diffeomorphic image registration with a key novelty that defines a symmetric similarity metric on harmonic phase volumes from multiple orientations. The material property of harmonic phase solves the aperture problem of optical flow and intensity-based methods and is robust to tag fading. A harmonic magnitude volume is used in enforcing incompressibility in the tissue regions. The estimated motion fields are dense, incompressible, diffeomorphic, and inverse-consistent at a 3-D voxel level. The method was evaluated using simulated phantoms, human brain data in mild head accelerations, human tongue data during speech, and an open cardiac data set. The method shows comparable accuracy to three existing methods while demonstrating low computation time and robustness to tag fading and noise.

29 October 2015 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
OAOsama M. Abdullah
Osama M. Abdullah
AGArnold David Gomez
Arnold David Gomez
SMSamer Merchant
Samer Merchant
MHMichael Heidinger
Michael Heidinger
SPSteven Poelzing
Steven Poelzing
EHEdward W. Hsu
Edward W. Hsu

8 October 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
AGArnold David Gomez
Arnold David Gomez
AKAndrew K. Knutsen
Andrew K. Knutsen
FXFangxu Xing
Fangxu Xing
YLYuan-Chiao Lu
Yuan-Chiao Lu
DCDeva Chan
Deva Chan
JPJerry L Prince
Jerry L Prince
Objective: To obtain dense spatiotemporal measurements of brain deformation from two distinct but complementary head motion experiments: linear and rotational accelerations. Methods: This study introduces a strategy for integrating harmonic phase analysis of tagged magnetic resonance imaging (MRI) and finite element models to extract mechanically representative deformation measurements. The method was calibrated using simulated as well as experimental data, demonstrated in a phantom including data with image artifacts, and used to measure brain deformation in human volunteers undergoing rotational and linear acceleration. Results: Evaluation methods yielded a displacement error of 1.1 mm compared to human observers, and strain errors between 0.1 $\pm$ 0.2% (mean $\pm$ std. dev.) for linear acceleration and 0.7 $\pm$ 0.3% for rotational acceleration. In the presence of inconsistent or missing data, we demonstrate an approach that can provide an error reduction of 86%. Analysis of results shows consistency with 2D motion estimation, agreement with external sensors, and the expected physical behavior of the brain. Conclusion: Mechanical regularization is useful for obtaining dense spatiotemporal measurements of in-vivo brain deformation under different loading regimes. Significance: The measurements suggest that the brain's 3D response to mild accelerations includes distinct patterns observable using practical MRI resolutions. This type of measurement can provide validation data for computer models for the study of traumatic brain injury (TBI).

7 February 2020 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
AGArnold D. Gomez
Arnold D. Gomez
MSMaureen L. Stone
Maureen L. Stone
JWJonghye Woo
Jonghye Woo
FXFangxu Xing
Fangxu Xing
JPJerry L. Prince
Jerry L. Prince
This study investigates mechanical cooperation among tongue muscles. Five volunteers were imaged using tagged magnetic resonance imaging to quantify spatiotemporal kinematics while speaking. Waveforms of strain in the line of action of fibers (SLAF) were estimated by projecting strain tensors onto a model of fiber directionality. SLAF waveforms were temporally aligned to determine consistency across subjects and correlation across muscles. The cohort exhibited consistent patterns of SLAF, and muscular extension-contraction was correlated. Volume-preserving tongue movement in speech generation can be achieved through multiple paths, but the study reveals similarities in motion patterns and muscular action—despite anatomical (and other) dissimilarities.

3 August 2016 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
OAOsama M. Abdullah
Osama M. Abdullah
TSThomas Seidel
Thomas Seidel
MDMarJanna Dahl
MarJanna Dahl
AGArnold David Gomez
Arnold David Gomez
GYGavin Yiep
Gavin Yiep
EHEdward W. Hsu
Edward W. Hsu