Desmond Teck Beng Yeo

Dr. Desmond Teck Beng Yeo

Biology and Applied Physics Department, General Electric Global Research, Niskayuna, NY 12309, USA
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2011 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
Desmond Teck Beng YeoDesmond Teck Beng Yeo
Desmond Teck Beng Yeo
ZWZhangwei Wang
Zhangwei Wang
WLWolfgang Loew
Wolfgang Loew
MVMika W. Vogel
Mika W. Vogel
IHIleana Hancu
Ileana Hancu
Purpose: To use electromagnetic (EM) simulations to study the effects of body type, landmark position, and radiofrequency (RF) body coil type on peak local specific absorption rate (SAR) in 3T magnetic resonance imaging (MRI). Materials and Methods: Numerically computed peak local SAR for four human body models (HBMs) in three landmark positions (head, heart, pelvic) were compared for a high‐pass birdcage and a transverse electromagnetic 3T body coil. Local SAR values were normalized to the IEC whole‐body average SAR limit of 2.0 W/kg for normal scan mode. Results: Local SAR distributions were highly variable. Consistent with previous reports, the peak local SAR values generally occurred in the neck‐shoulder area, near rungs, or between tissues of greatly differing electrical properties. The HBM type significantly influenced the peak local SAR, with stockier HBMs, extending extremities towards rungs, displaying the highest SAR. There was also a trend for higher peak SAR in the head‐centric and heart‐centric positions. The impact of the coil types studied was not statistically significant. Conclusion: The large variability in peak local SAR indicates the need to include more than one HBM or landmark position when evaluating safety of body coils. It is recommended that an HBM with arms near the rungs be included to create physically realizable high‐SAR scenarios. J. Magn. Reson. Imaging 2011;33:1209–1217.

3 January 2019 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
ASA. Sreekumari
A. Sreekumari
DSD. Shanbhag
D. Shanbhag
Desmond Teck Beng YeoDesmond Teck Beng Yeo
Desmond Teck Beng Yeo
TFT. Foo
T. Foo
JPJulie G. Pilitsis
Julie G. Pilitsis
IHI. Hancu
I. Hancu
BACKGROUND AND PURPOSE: MR imaging rescans and recalls can create large hospital revenue loss. The purpose of this study was to develop a fast, automated method for assessing rescan need in motion-corrupted brain series. MATERIALS AND METHODS: A deep learning–based approach was developed, outputting a probability for a series to be clinically useful. Comparison of this per-series probability with a threshold, which can depend on scan indication and reading radiologist, determines whether a series needs to be rescanned. The deep learning classification performance was compared with that of 4 technologists and 5 radiologists in 49 test series with low and moderate motion artifacts. These series were assumed to be scanned for 2 scan indications: screening for multiple sclerosis and stroke. RESULTS: The image-quality rating was found to be scan indication– and reading radiologist–dependent. Of the 49 test datasets, technologists created a mean ratio of rescans/recalls of (4.7 ± 5.1)/(9.5 ± 6.8) for MS and (8.6 ± 7.7)/(1.6 ± 1.9) for stroke. With thresholds adapted for scan indication and reading radiologist, deep learning created a rescan/recall ratio of (7.3 ± 2.2)/(3.2 ± 2.5) for MS, and (3.6 ± 1.5)/(2.8 ± 1.6) for stroke. Due to the large variability in the technologists9 assessments, it was only the decrease in the recall rate for MS, for which the deep learning algorithm was trained, that was statistically significant (P = .03). CONCLUSIONS: Fast, automated deep learning–based image-quality rating can decrease rescan and recall rates, while rendering them technologist-independent. It was estimated that decreasing rescans and recalls from the technologists9 values to the values of deep learning could save hospitals $24,000/scanner/year.

4 April 2014 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
Margarethus PaulidesMargarethus Paulides
Margarethus Paulides
JBJ F Bakker
J F Bakker
LHLorne Hofstetter
Lorne Hofstetter
WNW C M Numan
W C M Numan
RPR Pellicer
R Pellicer
GKG Kotek
G Kotek
Clinical studies have established a strong benefit from adjuvant mild hyperthermia (HT) to radio- and chemotherapy for many tumor sites, including the head and neck (H&N). The recently developed HYPERcollar allows the application of local radiofrequency HT to tumors in the entire H&N. Treatment quality is optimized using electromagnetic and thermal simulators and, whenever placement risk is tolerable, assessed using invasively placed thermometers. To replace the current invasive procedure, we are investigating whether magnetic resonance (MR) thermometry can be exploited for continuous and 3D thermal dose assessment. In this work, we used our simulation tools to design an MR compatible laboratory prototype applicator. By simulations and measurements, we showed that the redesigned patch antennas are well matched to 50 Ω (S11<-10 dB). Simulations also show that, using 300 W input power, a maximum specific absorption rate (SAR) of 100 W kg(-1) and a temperature increase of 4.5 °C in 6 min is feasible at the center of a cylindrical fat/muscle phantom. Temperature measurements using the MR scanner confirmed the focused heating capabilities and MR compatibility of the setup. We conclude that the laboratory applicator provides the possibility for experimental assessment of the feasibility of hybrid MR-HT in the H&N region. This versatile design allows rigorous analysis of MR thermometry accuracy in increasingly complex phantoms that mimic patients' anatomies and thermodynamic characteristics.

1 January 2021 in International Journal of Hyperthermia
Verified
Journal Article
Open access
TDTomas Drizdal
Tomas Drizdal
KSKemal Sumser
Kemal Sumser
GBGennaro G. Bellizzi
Gennaro G. Bellizzi
Ondrej FiserOndrej Fiser
Ondrej Fiser
JVJan Vrba
Jan Vrba
Margarethus PaulidesMargarethus Paulides
Margarethus Paulides
To develop a head and neck hyperthermia phased array system compatible with a 1.5 T magnetic resonance (MR) scanner for noninvasive thermometry.We designed a dielectric-parabolic-reflector antenna ...

21 May 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
KGKatie Y. Gandomi
Katie Y. Gandomi
PCPaulo A. W. G. Carvalho
Paulo A. W. G. Carvalho
MTMatthew Tarasek
Matthew Tarasek
EFEric W. Fiveland
Eric W. Fiveland
CBChitresh Bhushan
Chitresh Bhushan
GFGregory S. Fischer
Gregory S. Fischer
The primary objective of cancer intervention is the selective removal of malignant cells while conserving surrounding healthy tissues. However, the accessibility, size and shape of the cancer can make achieving appropriate margins a challenge. One minimally invasive treatment option for these clinical cases is interstitial needle based therapeutic ultrasound (NBTU). In this work, we develop a finite element model (FEM) capable of simulating continuous rotation of a directional NBTU applicator. The developed model was used to simulate the thermal deposition for different rotation trajectories. The actual thermal deposition patterns for the simulated trajectories were then evaluated using magnetic resonance thermal imaging (MRTI) in a porcine skin gelatin phantom. An MRI-compatible robot was used to control the rotation motion profile of the physical NBTU applicator to match the simulated trajectory. The model showed agreement when compared to experimental measurements with Pearson correlation coefficients greater than 0.839 when comparing temperature fields within an area of 12.6 mm radius from the ultrasound applicator. The average temperature error along a 6.3 mm radius profile from the applicator was 1.27 ° C. The model was able to compute 1 s of thermal deposition by the applicator in 0.2 s on average with a 0.1 mm spatial resolution and 0.5 s time steps. The developed simulation demonstrates performance suitable for real-time control which may enable robotically-actuated closed-loop conformal tumor ablation.

3 February 2016 in Journal of Therapeutic Ultrasound
Verified
Journal Article
Open access
PDF file
SLSilke M. Lechner-Greite
Silke M. Lechner-Greite
NHNicolas Hehn
Nicolas Hehn
BWBeat Werner
Beat Werner
EZEyal Zadicario
Eyal Zadicario
MTMatthew Richard Tarasek
Matthew Richard Tarasek
Desmond Teck Beng YeoDesmond Teck Beng Yeo
Desmond Teck Beng Yeo
The study aims to investigate different ground plane segmentation designs of an ultrasound transducer to reduce gradient field induced eddy currents and the associated geometric distortion and temperature map errors in echo-planar imaging (EPI)-based MR thermometry in transcranial magnetic resonance (MR)-guided focused ultrasound (tcMRgFUS). Six different ground plane segmentations were considered and the efficacy of each in suppressing eddy currents was investigated in silico and in operando. For the latter case, the segmented ground planes were implemented in a transducer mockup model for validation. Robust spoiled gradient (SPGR) echo sequences and multi-shot EPI sequences were acquired. For each sequence and pattern, geometric distortions were quantified in the magnitude images and expressed in millimeters. Phase images were used for extracting the temperature maps on the basis of the temperature-dependent proton resonance frequency shift phenomenon. The means, standard deviations, and signal-to-noise ratios (SNRs) were extracted and contrasted with the geometric distortions of all patterns. The geometric distortion analysis and temperature map evaluations showed that more than one pattern could be considered the best-performing transducer. In the sagittal plane, the star (d) (3.46 ± 2.33 mm) and star-ring patterns (f) (2.72 ± 2.8 mm) showed smaller geometric distortions than the currently available seven-segment sheet (c) (5.54 ± 4.21 mm) and were both comparable to the reference scenario (a) (2.77 ± 2.24 mm). Contrasting these results with the temperature maps revealed that (d) performs as well as (a) in SPGR and EPI. We demonstrated that segmenting the transducer ground plane into a star pattern reduces eddy currents to a level wherein multi-plane EPI for accurate MR thermometry in tcMRgFUS is feasible.