1 January 2019 in IEEE Transactions on Power Electronics
In a dual active bridge (DAB) dc-dc converter, modulating the phase shift ratios can suppress reactive power and increase efficiency under non-unity voltage gain conditions. Derivation of the optimal shift ratios to achieve the minimum reactive power is challenging as a DAB can operate in four different scenarios (forward/backward, buck/boost) and each scenario has five operating modes. This paper firstly introduces a transformation that different DAB operating scenarios (forward/backward, buck/boost) can be equivalent to each other, then only optimization of one scenario (forward/buck) is required. Next, for the five modes in forward/buck scenario, based on a graphical method, this paper proves that each operating point of Mode 1, 2 and 5 can be mapped into that of Mode 3 with lower conduction losses, and only two modes (Mode 3 and 4) require detailed analysis. The optimization process of these two modes are derived step by step. Global optimal phase shift signals that minimizing the reactive power under four different DAB operating scenarios (forward/backward, buck/boost) are presented. A simple table and control block diagram are presented for practical implementation of global reactive power minimization control. Experimental comparison with other modulation schemes verifies the efficiency improvement of the proposed control method.
24 December 2019 in IEEE Transactions on Power Electronics
A modular multilevel resonant (MMR) DC-DC converter and its modulation and control are proposed in this paper. The MMR converter inherits the desirable features of both the modular multilevel converter and LLC resonant converter such as high voltage capability, easy fault tolerant operation and soft switching. Besides, the MMR can regulate the output voltage over a wide input voltage range with much narrower frequency range compared to conventional resonant converters. By constantly inserting certain number of submodules into the arm according to the input voltage, the resonant tank voltage can be regulated with a relatively constant amplitude regardless of the wide input variation. This modulation technique is acted as a feedforward loop to roughly regulate the output according to the input voltage, and the feedback loop in the control system precisely regulates the output by varying the switching frequency. Simulations on a 200kW MMR that converting 9~15kV to 750V are provided to verify the effectiveness of the proposed topology and control method. Experimental results on a MMR prototype are also given to demonstrate the feasibility.
14 October 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
12 May 2020 in IEEE Transactions on Industrial Electronics
9 April 2018 in IEEE Transactions on Power Electronics
This paper proposes a high efficiency single-phase T-type BCM microinverter. The conventional full-bridge BCM microinverter has achieved ZVS soft switching and thereby improved the efficiency, but it suffers from high switching losses in light load conditions. The proposed T-type BCM microinverter reserves ZVS soft switching and uses multilevel technique to further decrease the switching losses. The BCM operation with multilevel technique will have too low switching frequency when the grid voltage approaches half of the DC link voltage. To solve this problem, this paper adopts a third operation mode for the T-type switching leg to maintain the switching frequency above a minimum value. The corresponding mode transitions are also detailed to ensure a smooth operation. Because of the turn-off delay of the freewheeling transistor, the actual lower current boundary deviates from the programmed one, which will distort output current. To address this issue, this paper also proposes a boundary compensation method. A prototype has been built for performance verification, which can test both full-bridge and T-type topology. Compared with the full-bridge BCM microinverter, the proposed T-type BCM microinverter has a higher efficiency over the whole load range.
7 February 2023 in IEEE Transactions on Power Electronics
In high-power applications, parallel connection of discrete silicon carbide (SiC) mosfet s is necessary to increase the current rating. However, the unbalanced dynamic current during switching transient may cause unequal power loss and thermal distribution, which is a great challenge in parallel applications. In this article, a dynamic current balancing method based on a new active gate driver (AGD) is proposed to improve the current sharing. The principle of the AGD is based on di/dt feedback control and voltage controlled current source to adjust gate drive current of SiC mosfet s. Therefore, the switching trajectory of the paralleled devices can be changed to achieve current balance. In addition, by using master-slave control strategy, the proposed AGD can be easily used for multiple paralleled devices. The double pulse tests are conducted to verify the effectiveness of the proposed AGD. For two paralleled devices, the turn- on and turn- off switching energy imbalances are reduced from 13.4% and 56.0% (12.1% and 52.9%) to 8.8% and 15.3% (8.0% and 8.8%) by the current source (current sink) circuit. For six paralleled devices, the degrees of turn- on and turn- off switching energy imbalances can be reduced from 21.8% and 16.1% to 11.8% and 7.8% by the proposed AGD.