14 January 2010 in Lab on a Chip
We developed a carbon nanotube (CNT)-based biosensor system-on-a-chip (SoC) for the detection of a neurotransmitter. Here, 64 CNT-based sensors were integrated with silicon-based signal processing circuits in a single chip, which was made possible by combining several technological breakthroughs such as efficient signal processing, uniform CNT networks, and biocompatible functionalization of CNT-based sensors. The chip was utilized to detect glutamate, a neurotransmitter, where ammonia, a byproduct of the enzymatic reaction of glutamate and glutamate oxidase on CNT-based sensors, modulated the conductance signals to the CNT-based sensors. This is a major technological advancement in the integration of CNT-based sensors with microelectronics, and this chip can be readily integrated with larger scale lab-on-a-chip (LoC) systems for various applications such as LoC systems for neural networks.
28 November 2016 in Applied Physics Letters
We report a simple and efficient electrical sensing scheme that can be used to overcome the “diffusion limit” of affinity-based biosensors by incorporating the structural advantage of a concentric electrode biosensor platform and the microstirring effect of AC electrothermal flow (ACEF). To prove the effect of ACEF on the biosensor performance, we performed both simulations and experiments for the detection of cardiac troponin-I, which is a biomarker for acute myocardial infarction. The finite element simulation results indicate that AC bias to the electrode (which has a concentric structure in our device) can induce fast convection flow, which facilitates the transport of the target molecules to the binding region located between the two electrodes. In our device, the channel region made of a carbon nanotube network decorated with gold nanoparticles, which act as the attaching sites of the probe molecules, is used as a highly sensitive electrical channel. We find that the electrical sensing method exhibited extremely fast sensing speeds compared with those under no bias (diffusion-limited) conditions.
1 July 2013 in Lab on a Chip
In this paper, we investigate the effect of electrical pulse bias on DNA hybridization events in a biosensor platform, using a Carbon Nanotube Network (CNN) and Gold Nano Particles (GNP) as an electrical channel. The scheme provides both hybridization rate enhancement of bio molecules, and electrical measurement in a transient state to avoid the charge screening effect, thereby significantly improving the sensitivity. As an example, the probe DNA molecules oscillate with pulse trains, resulting in the enhancement of DNA hybridization efficiency, and accordingly of the sensor performances in Tris–EDTA (TE) buffer solution, by as much as over three times, compared to the non-biasing conditions. More importantly, a wide dynamic range of 106 (target-DNA concentration from 5 pM to 5 μM) is achieved in human serum. In addition, the pulse biasing method enables one to obtain the conductance change, before the ions within the Electrical Double Layer (EDL) are redistributed, to avoid the charge screening effect, leading to an additional sensitivity enhancement.
19 August 2010 in IEEE Transactions on Electron Devices
A carbon nanotube network device having concentric-shaped electrodes (source and drain) is analyzed to examine the "self-gating" effect of various pH buffer solutions on its electrical properties. Using the 2-D homogeneous percolation theory, current-voltage characteristics of the devices are described as the classical MOSFET formula, in which the device is modeled as the p-type transistor with positive threshold voltage and the gate is tied with the drain (at positive bias) or source (at negative bias). To determine the apparent threshold voltage change due to the corresponding pH value, the ∂VD/∂ID (VD:drain voltage; ID:drain current) curve is extracted from the measured current-voltage characteristics to find VD_SAT(= -VTH, VQS = 0). A threshold voltage shift according to the pH value is observed without an external gate electrode, showing the possibility of relaxing the requirement of the external gate electrode. By grafting protonation/deprotonation which occurs in the carboxylated single-walled carbon nanotubes, the decaying current as pH increases is explained. Better sensitivity according to the operation regime is examined by the device modeling.