Kenan Niu

Dr. Kenan Niu

EEMCS, University of Twente, Enschede, The Netherlands
orcid
Robotic intelligence and vision

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
DWDi Wu
Di Wu
XHXuan Thao Ha
Xuan Thao Ha
YZYao Zhang
Yao Zhang
MOMouloud Ourak
Mouloud Ourak
GBGianni Borghesan
Gianni Borghesan
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
In cardiovascular interventions, when steering catheters and especially robotic catheters, great care should be paid to prevent applying too large forces on the vessel walls as this could dislodge calcifications, induce scars or even cause perforation. To address this challenge, this paper presents a novel compliant motion control algorithm that relies solely on position sensing of the catheter tip and knowledge of the catheter’s behavior. The proposed algorithm features a data-driven tip position controller. The controller is trained based on a so-called control Long Short-Term Memory Network (control-LSTM). Trajectory following experiments are conducted to validate the quality of the proposed control-LSTM. Results demonstrated superior positioning capability with sub-degree precision of the new approach in the presence of severe rate-dependent hysteresis. Experiments both in a simplified setup as well as in an aortic phantom further show that the proposed approach allows reducing the interaction forces with the environment by around 70%. This work shows how deep learning can be exploited advantageously to avoid tedious modeling that would be needed to precisely steer continuum robots in constrained environments such as the patient’s vasculature.

12 May 2023 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
RLRuixuan Li
Ruixuan Li
ADAyoob Davoodi
Ayoob Davoodi
YCYuyu Cai
Yuyu Cai
KNKenan Niu
Kenan Niu
GBGianni Borghesan
Gianni Borghesan
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten

13 June 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KNKenan Niu
Kenan Niu
JHJasper Homminga
Jasper Homminga
VSVictor I Sluiter
Victor I Sluiter
ASAndré Sprengers
André Sprengers
NVNico Verdonschot
Nico Verdonschot
A fast and accurate intraoperative registration method is important for Computer-Aided Orthopedic Surgery (CAOS). A-mode ultrasound (US) is able to acquire bone surface data in a non-invasive manner. To utilize A-mode US in CAOS, a suitable registration algorithm is necessary with a small number of registration points and the presence of measurement errors. Therefore, we investigated the effects of (1) the number of registration points and (2) the Ultrasound Point Localization Error (UPLE) on the overall registration accuracy. We proposed a new registration method (ICP-PS), including the Iterative Closest Points (ICP) algorithm and a Perturbation Search algorithm. This method enables to avoid getting stuck in the local minimum of ICP iterations and to find the adjacent global minimum. This registration method was subsequently validated in a numerical simulation and a cadaveric experiment using a 3D-tracked A-mode US system. The results showed that ICP-PS outperformed the standard ICP algorithm. The registration accuracy improved with the addition of ultrasound registration points. In the numerical simulation, for 25 sample points with zero UPLE, the averaged registration error of ICP-PS reached 0.25 mm, while 1.71 mm for ICP, decreasing by 85.38%. In the cadaver experiment, using 25 registration points, ICP-PS achieved an RMSE of 2.81 mm relative to 5.84 mm for the ICP, decreasing by 51.88%. The simulation approach provided a well-defined framework for estimating the necessary number of ultrasound registration points and acceptable level of UPLE for a given required level of accuracy for intraoperative registration in CAOS. ICP-PS method is suitable for A-mode US based intraoperative registration. This study would facilitate the application of A-mode US probe in registering the point cloud to a known shape model, which also has the potential for accurately estimating bone position and orientation for skeletal motion tracking and surgical navigation.

8 February 2025 in Technologies
Verified
Journal Article
Open access
PDF file
DSD SUN
D SUN
ACAlessandro Cappellari
Alessandro Cappellari
BLBangyu Lan
Bangyu Lan
MAMomen Abayazid
Momen Abayazid
SSStefano Stramigioli
Stefano Stramigioli
KNKenan Niu
Kenan Niu
Musculoskeletal ultrasound (US) imaging faces challenges such as operator experience, limited spatial flexibility, and high personnel costs. This study introduces an Automated Robotic Ultrasound Scanning (ARUS) system that integrates key technological advancements to automate the ultrasound scanning procedure with the robot, including anatomical target localization, automatic trajectory generation, deep-learning-based segmentation, and 3D reconstruction of musculoskeletal structures. The ARUS system consists of a robotic arm, ultrasound imaging, and stereo vision for precise anatomical area detection. A Graphical User Interface (GUI) facilitates a flexible selection of scanning trajectories, improving user interaction and enabling customized US scans. To handle complex and dynamic curvatures on the skin, together with anatomical area detection, the system employs a hybrid position–force control strategy based on the generated trajectory, ensuring stability and accuracy. Additionally, the utilized RA-UNet model offers multi-label segmentation on the bone and muscle tissues simultaneously, which incorporates residual blocks and attention mechanisms to enhance segmentation accuracy and robustness. A custom musculoskeletal phantom was used for validation. Compared to the reference 3D reconstruction result derived from the MRI scan, ARUS achieved a 3D reconstruction root mean square error (RMSE) of 1.22 mm, with a mean error of 0.94 mm and a standard deviation of 0.77 mm. The ARUS system extends 3D musculoskeletal imaging capacity by enabling both bones and muscles to be segmented and reconstructed into 3D shapes in real time and simultaneously. These features suggest significant potential as a cost-effective and reliable option for musculoskeletal examination and diagnosis in real-time applications.

26 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MTMaikel Timmermans
Maikel Timmermans
AMAidana Massalimova
Aidana Massalimova
RLRuixuan Li
Ruixuan Li
ADAyoob Davoodi
Ayoob Davoodi
QGQuentin Goossens
Quentin Goossens
KDKathleen Denis
Kathleen Denis
In the research field of robotic spine surgery, there is a big upcoming momentum for surgeon-like autonomous behaviour and surgical accuracy in robotics which goes beyond the standard engineering notions such as geometric precision. The objective of this review is to present an overview of the state of the art in non-visual, non-radiative spine sensing for the enhancement of surgical techniques in robotic automation. It provides a vantage point that facilitates experimentation and guides new research projects to what has not been investigated or integrated in surgical robotics. Studies were identified, selected and processed according to the PRISMA guidelines. Relevant study characteristics that were searched for include the sensor type and measured feature, the surgical action, the tested sample, the method for data analysis and the system’s accuracy of state identification. The 6DOF f/t sensor, the microphone and the electromyography probe were the most commonly used sensors in each category, respectively. The performance of the electromyography probe is unsatisfactory in terms of preventing nerve damage as it can only signal after the nerve is disturbed. Feature thresholding and artificial neural networks were the most common decision algorithms for state identification. The fusion of different sensor data in the decision algorithm improved the accuracy of state identification.

6 October 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
VVViktor Vörös
Viktor Vörös
RLRuixuan Li
Ruixuan Li
ADAyoob Davoodi
Ayoob Davoodi
GWGauthier Wybaillie
Gauthier Wybaillie
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
KNKenan Niu
Kenan Niu
Robot-assisted surgery is becoming popular in the operation room (OR) for, e.g., orthopedic surgery (among other surgeries). However, robotic executions related to surgical steps cannot simply rely on preoperative plans. Using pedicle screw placement as an example, extra adjustments are needed to adapt to the intraoperative changes when the preoperative planning is outdated. During surgery, adjusting a surgical plan is non-trivial and typically rather complex since the available interfaces used in current robotic systems are not always intuitive to use. Recently, thanks to technical advancements in head-mounted displays (HMD), augmented reality (AR)-based medical applications are emerging in the OR. The rendered virtual objects can be overlapped with real-world physical objects to offer intuitive displays of the surgical sites and anatomy. Moreover, the potential of combining AR with robotics is even more promising; however, it has not been fully exploited. In this paper, an innovative AR-based robotic approach is proposed and its technical feasibility in simulated pedicle screw placement is demonstrated. An approach for spatial calibration between the robot and HoloLens 2 without using an external 3D tracking system is proposed. The developed system offers an intuitive AR–robot interaction approach between the surgeon and the surgical robot by projecting the current surgical plan to the surgeon for fine-tuning and transferring the updated surgical plan immediately back to the robot side for execution. A series of bench-top experiments were conducted to evaluate system accuracy and human-related errors. A mean calibration error of 3.61 mm was found. The overall target pose error was 3.05 mm in translation and 1.12∘ in orientation. The average execution time for defining a target entry point intraoperatively was 26.56 s. This work offers an intuitive AR-based robotic approach, which could facilitate robotic technology in the OR and boost synergy between AR and robots for other medical applications.