Cemre Cöddü

Cemre Cöddü

Auto-generated profile, based on publicly available information

Cemre Cöddü

Department of Neurology, University of Health Sciences Adana City Training and Research Hospital, Adana, Türkiye

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2025 in Clinical Neurology and Neurosurgery
Verified
Journal Article
Closed access
ESElif Banu Soker
Elif Banu Soker
MEMiray Erdem
Miray Erdem
DODerya Ozdogru
Derya Ozdogru
CCCemre Coddu
Cemre Coddu
MGMÜGE GÜLEN
MÜGE GÜLEN

18 May 2026 in BMC Neurology
Verified
Journal Article
Open access
HAHalil Can Alaydın
Halil Can Alaydın
AFASLIHAN FİDANCI
ASLIHAN FİDANCI
İYİrem Yakıcı
İrem Yakıcı
CCCemre Cöddü
Cemre Cöddü
SBSeda Mencekoglu Bastin
Seda Mencekoglu Bastin
SMSemir Mazman
Semir Mazman
Superficial radial neuropathy (SRN) is an uncommon sensory mononeuropathy, and data on neuropathic pain in SRN are limited. This study aimed to determine the frequency of neuropathic pain in patients with SRN and to evaluate its associations with neurophysiological severity. We retrospectively reviewed adult patients diagnosed with SRN. Neuropathic pain was evaluated using the Douleur Neuropathique 4 Questions (DN4) and the Leeds Assessment of Neuropathic Symptoms and Signs (LANSS). Neurophysiological severity was categorized as mild, moderate, or severe according to the superficial radial sensory nerve action potential (SNAP) amplitude. Associations between neuropathic pain and SRN severity, etiology, and coexisting upper-limb neuropathies were examined. Twenty patients were included (mean age 36.2 ± 11.9 years; 75% male). SRN was trauma-related in 18 patients and entrapment-related in 2. Ten patients (50%) met screening criteria for neuropathic pain according to DN4 and 9 (45%) according to LANSS. Screening positivity tended to be more frequent in severe SRN than in mild-moderate SRN (DN4: 6/7 vs. 4/13, p = 0.057) and was significantly higher according to LANSS (6/7 vs. 3/13, p = 0.012). Screening positivity was also observed in 3/4 patients with coexisting median or ulnar neuropathies. Approximately half of patients with SRN met screening criteria for neuropathic pain. Higher screening positivity was observed in electrophysiologically severe SRN and in patients with coexisting median or ulnar neuropathies; these findings warrant confirmation in larger prospective cohorts.

16 October 2025 in BMC Neuroscience
Verified
Journal Article
Open access
PDF file
AFASLIHAN FİDANCI
ASLIHAN FİDANCI
HAHalil Can Alaydın
Halil Can Alaydın
CCCemre Cöddü
Cemre Cöddü
İYİrem Yakıcı
İrem Yakıcı
ZAZülfikar Arlıer
Zülfikar Arlıer
Phosphenes can be induced by applying transcranial magnetic stimulation (TMS) to the visual cortex. Since multiple factors influence phosphene perception, this study aimed to examine the effects of different TMS coil types on phosphene thresholds (PTs). Additionally, the relationship between PT and motor cortex excitability was explored. In Session 1, TMS was applied to the left visual cortex of 22 healthy individuals using a round coil and a figure-eight coil, and PT was recorded. Resting motor threshold (RMT), active motor threshold (AMT), and short-interval intracortical inhibition (SICI) were assessed by stimulating the left motor cortex. After 5–7 days, the visual cortex was stimulated again in Session 2 with the same healthy individuals. In Session 1, the mean PTs obtained with the round and figure-eight coils were 39.71 ± 9.67% (n = 17) and 53.93 ± 14.26% (n = 15), respectively (p = 0.001). In Session 2, the mean PTs were 37.83 ± 11.34% and 51.53 ± 14.03% (p = 0.001) for the round and figure-eight coils, respectively. The intraclass correlation coefficients for PTs across studies were 0.832 for the round coil and 0.591 for the figure-eight coil. No significant correlation was found between PT and AMT, RMT, or SICI. PTs were lower with the round coil than with the figure-eight coil. The reliability of PTs can be considered good for round coil and moderate for figure-eight coil. Additionally, the findings suggested that motor cortex and visual cortex excitability are different entities.