Barbara de Araujo Lima Dutra

Barbara de Araujo Lima Dutra

Auto-generated profile, based on publicly available information

Barbara de Araujo Lima Dutra

From the Cole Eye Institute (H.Z., B.H., B.N.S., B.A.L.D., J.B.R.), Cleveland Clinic, Cleveland, Ohio, USA; Department of Ophthalmology (B.N.S., B.A.L.D.), University of Sao Paulo, Sao Paulo, Brazil

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2025 in American Journal of Ophthalmology
Verified
Journal Article
Open access
BDBarbara A. L. Dutra
Barbara A. L. Dutra
BHBassel Hammoud
Bassel Hammoud
BSBianca N. Susanna
Bianca N. Susanna
LALara Asroui
Lara Asroui
GSGiuliano Scarcelli
Giuliano Scarcelli
JRJ. Bradley Randleman
J. Bradley Randleman
To evaluate the utility of automated epithelial thickness metrics to identify subclinical keratoconus (SKC) through epithelial thickness pattern comparisons between normal controls, (SKC), and manifest keratoconus (KC). Retrospective cross-sectional study. There were 200 eyes from 200 patients evaluated, including: (1) 100 control eyes from 100 patients with bilaterally normal corneal topography/tomography and slit-lamp examination (controls); (2) 50 eyes from 50 patients with SKC; (3) 50 eyes from 50 patients with KC. Epithelial mapping was performed using anterior segment optical coherence tomography (AS-OCT) imaging (Avanti RTVue XR, Optovue). Area under the receiver operating characteristic (AUROC) curves were used to determine the overall discriminative accuracy of the significant test parameters as described by the area under the curve (AUC) and to calculate the sensitivity and specificity of each parameter. There were no differences between control and SKC groups in any regional OCT epithelial thickness parameter. Among relational epithelial thickness metrics, only superonasal - inferotemporal (SN-IT) value differences reached statistical significance between control and SKC groups (-0.81 μm versus 0.41 μm), but this metric still showed limited performance in differentiating groups (AUROC = 0.68). Most stromal thickness values were significantly different between SKC and controls. Epithelial thickness patterns were not effective as a primary metric to identify subclinical keratoconus. Scheimpflug metrics and regional stromal thickness values significantly outperformed epithelial metrics in differentiating both SKC and KC eyes from controls. Epithelial mapping metrics thus appear significantly less sensitive than predicted for subclinical keratoconus detection in early disease manifestations.

14 April 2015 in Sao Paulo Medical Journal
Verified
Journal Article
Open access
PDF file
JLJose Juvenal Linhares
Jose Juvenal Linhares
BDBárbara De Araújo Lima Dutra
Bárbara De Araújo Lima Dutra
MPMaycon Fellipe Da Ponte
Maycon Fellipe Da Ponte
LTLuis Fernando Farah De Tofoli
Luis Fernando Farah De Tofoli
PTPriscila Campos Távora
Priscila Campos Távora
GAGuarany Mont'Alverne De Arruda
Guarany Mont'Alverne De Arruda
CONTEXT AND OBJECTIVE: This research project arose from a proposal made to the teachers by the students of a medical course at a federal university in Brazil, from their personal experiences regarding the skills and competencies that should be developed during the obstetrics and gynecology (OBG) stage of the internship. The objective here was to develop the matrix of skills necessary for training good general physicians in the medical course.DESIGN AND SETTING: Exploratory qualitative study conducted in a federal university in Brazil.METHODS: The basis for developing these competencies among OBG interns was "The Competency Matrix for Medical Internship" developed by Bollela and Machado. The instrument was presented to, analyzed by and modified by a set of OBG specialists, at two sessions.RESULTS: The specific competencies expected from students over the internship in OBG were framed within overall topics that had previously been determined and listed: healthcare, decision-making, communication and interpersonal relationships, management and organization of the Brazilian National Health System (Sistema Único de Saúde, SUS) and professionalism.CONCLUSIONS: A competency matrix that standardizes the minimum requirements that interns should be capable of putting into practice after concluding the OBG stage is a valuable tool for ensuring student performance and a fair and rigorous assessment for them, thereby seeking to train good general physicians who meet the community's needs.

26 February 2026 in American Journal of Ophthalmology
Verified
Journal Article
Open access
HZHongyuan Zhang
Hongyuan Zhang
BHBassel Hammoud
Bassel Hammoud
BSBianca N. Susanna
Bianca N. Susanna
BDBarbara A.L. Dutra
Barbara A.L. Dutra
GSGiuliano Scarcelli
Giuliano Scarcelli
JRJ. Bradley Randleman
J. Bradley Randleman
To compare the diagnostic efficacy of motion-tracking (MT) Brillouin microscopy with multimodal corneal imaging for keratoconus suspect (KCS) identification. Prospective, cross-sectional diagnostic evaluation. There were 56 eyes from 56 patients evaluated, including 28 eyes from 28 bilaterally normal control patients and 28 eyes from 28 keratoconus suspect patients. All patients underwent MT Brillouin microscopy using a custom-built device, Scheimpflug tomography, anterior segment optical coherence tomography (AS-OCT), and Corneal Visualization Scheimpflug Technology (Corvis ST). MT Brillouin microscopy data included mean (MTB-mean) and focal minimum (MTB-min) values within the anterior plateau region. The sensitivity, specificity, and area under the receiver operating characteristic curves (AUROC) were calculated for variables from all modalities. No significant demographic differences were found between groups except thinnest corneal thickness (556 μm Control vs 526 μm KCS; P < .001). MT Brillouin metrics MTB-min (AUC = 0.999, Sensitivity 100%, Specificity 96%) and MTB-mean (AUC 0.981, Sensitivity 93%, Specificity 100%) outperformed all other multimodal imaging metrics in KCS identification and group differentiation. MTB-min significantly outperformed all multimodal metrics, including the Corvis ST Tomographic and Biomechanical Index (TBI) (AUC 0.906, P = .018), Pentacam Random Forest Index (PRFI) (AUC 0.870, P = .005), Keratoconus Index (KI) (AUC 0.873, P = .005), and Index of Height Decentration (IHD) (AUC 0.859, P = .005). The best epithelial metric, Epi 5 mm ST-IN, performed poorly in group differentiation (AUC = 0.641). Motion-tracking Brillouin microscopy metrics effectively identified focal corneal weakening in keratoconus suspects and significantly outperformed all multimodal imaging metrics in differentiating keratoconus suspect eyes from normal controls.

31 January 2019 in The Open Ophthalmology Journal
Verified
Journal Article
Open access
PDF file
BDBarbara de Araujo Lima Dutra
Barbara de Araujo Lima Dutra
CCCarolina Lyra Barreira Carneiro
Carolina Lyra Barreira Carneiro
MGMariana Studart Mendonça Gomes
Mariana Studart Mendonça Gomes
RNRodrigo Dantas Nagashima
Rodrigo Dantas Nagashima
AMAndre Juca Machado
Andre Juca Machado
JCJoao Crispim
Joao Crispim
Background: Studies have shown a higher incidence of dry eye among patients with diabetes compared to patients without diabetes. However, information regarding dry eye in patients with proliferative diabetic retinopathy and laser therapy indication is not sufficient. Objective: To estimate the clinical manifestation of dry eye syndrome in patients with proliferative diabetic retinopathy and laser therapy indication. Method: A cross-sectional study was performed during a local evaluation campaign of diabetic patients with vision disabilities at the Instituto Cearense de Oftalmologia in Fortaleza, CE, Brazil. Patients with proliferative diabetic retinopathy and laser therapy indication were included in the study. An anamnesis directly to dry eye complaints was performed, and eligible participants completed the Ocular Surface Disease Index (OSDI) questionnaire. The slit lamp examination was performed with fluorescein staining; the tear break-up time (TBUT) was measured, and conjunctiva and corneal was evaluated using Rose Bengal (RB) staining. Finally, the Schirmer I test was performed. Results: Twenty-five patients were included in the study with a diagnostic time of Diabetes Mellitus ranged from 1 to 35 years, with an average of 17.2 ± 8.7 years. In our sample, 14 patients (56%) reported glycemic control with insulin, while 11 patients (44%) had oral hypoglycemic agents. The most prevalent complaint was blurred vision (96% of patients) followed by low visual acuity (92%). A less prevalent complaint was pain (44%). The mean OSDI score was 49.4 ± 24.2. TBUT was less than 10 seconds in 21 patients (84%), and RB staining grade was more than 3 in 13 patients (52%). The results of the Schirmer I test ranged from 2 to 35 mm, with a mean of 13.57 ± 9.78 mm. It was smaller than 10 mm in 15 patients (60%). Conclusion: The frequency of manifestation of dry eye syndrome was very common in patients with proliferative diabetic retinopathy and laser therapy indication. Ocular surface care should be provided for those patients with significant ocular morbidity.

13 April 2022 in Journal of Pharmacy and Nutrition Sciences
Verified
Journal Article
Open access
PDF file
BDBarbara de Araujo Lima Dutra
Barbara de Araujo Lima Dutra
CCCarolina Lyra Barreira Carneiro
Carolina Lyra Barreira Carneiro
NMNayanna de Oliveira Ramos Melo
Nayanna de Oliveira Ramos Melo
GOGilson Brito de Oliveira
Gilson Brito de Oliveira
FJFrancisco Vagnaldo Fechine Jamacaru
Francisco Vagnaldo Fechine Jamacaru
CDConceição Aparecida Dornelas
Conceição Aparecida Dornelas
This work aims to evaluate the effects of gum arabic and eugenol on inflammatory angiogenesis in a subcutaneous silica inoculum model. Ninety-six Wistar rats were distributed over 16 groups. The substances administered by gavage included distilled water, gum arabic (500 mg/100g weight), and eugenol (10mg/100g weight). Control groups received 0.2 mL of sterile distilled water subcutaneously. The experimental groups were subjected to an inoculum of 0.2 mL of silica solution (50 mg/mL) subcutaneously. For seven or 14 days, the groups received distilled water or gum arabic or eugenol or gum arabic plus eugenol. There was no difference between the histological analysis of slides stained with hematoxylin-eosin. There was a reduction in vascular density in animals that received only gum arabic for 7 (0.09 µm² ± 0.02) or 14 (0.08 µm² ± 0.03) days and only eugenol for seven days (0.08 µm² ± 0.03), but this was not statistically significant. The microvascular density significantly increased in the group treated with eugenol for 14 days (0.14 µm² ± 0.02). Eugenol reduced inflammatory angiogenesis when administered for seven days and stimulated it when administered for 14 days. Gum arabic had a potential inhibitory effect on this model. The study of inflammatory angiogenesis, induced by a silica inoculum in the subcutaneous tissue of rats, is a new and reproducible model for evaluating angiogenesis and inflammation.

14 January 2021 in Journal of Health & Biological Sciences
Verified
Journal Article
Open access
PDF file
JNJosé de Paula Barbosa Neto
José de Paula Barbosa Neto
BDBárbara de Araújo Lima Dutra
Bárbara de Araújo Lima Dutra
SSSarah Rubia Sales De Castro e Silva
Sarah Rubia Sales De Castro e Silva
JRJoão Crispim Moraes Lima Ribeiro
João Crispim Moraes Lima Ribeiro
Objective: Technological development has promoted several advances in society, including the creation of smartphones, which have been increasingly used in medicine, especially in ophthalmology. This study aimed to review the use of smartphones in ophthalmology. Methods: In January of 2020, the MEDLINE and LILACS databases were selected to provide articles containing the terms “Ophthalmology” and “Smartphone”, filtering the results between the years of 2015 and 2019. The evaluated outcomes were finally included into the following categories in the discussion: “Visual acuity”, “Amblyopia and strabismus”, “Anterior segment”, “Posterior segment”, “Glaucoma”, “Community patient education and assistance” and “Neurophthalmology”. Results: Smartphones can be useful in several different areas of ophthalmology and can provide the patients better understating and adhesion to their treatment. Conclusion: Applications can be used as tools to facilitate the work of several professionals and improve the understanding of patients about their clinical conditions.