Bassel Hammoud

Dr. Bassel Hammoud


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2025 in American Journal of Ophthalmology
Verified
Journal Article
Open access
BDBarbara A. L. Dutra
Barbara A. L. Dutra
BHBassel Hammoud
Bassel Hammoud
BSBianca N. Susanna
Bianca N. Susanna
LALara Asroui
Lara Asroui
GSGiuliano Scarcelli
Giuliano Scarcelli
JRJ. Bradley Randleman
J. Bradley Randleman
To evaluate the utility of automated epithelial thickness metrics to identify subclinical keratoconus (SKC) through epithelial thickness pattern comparisons between normal controls, (SKC), and manifest keratoconus (KC). Retrospective cross-sectional study. There were 200 eyes from 200 patients evaluated, including: (1) 100 control eyes from 100 patients with bilaterally normal corneal topography/tomography and slit-lamp examination (controls); (2) 50 eyes from 50 patients with SKC; (3) 50 eyes from 50 patients with KC. Epithelial mapping was performed using anterior segment optical coherence tomography (AS-OCT) imaging (Avanti RTVue XR, Optovue). Area under the receiver operating characteristic (AUROC) curves were used to determine the overall discriminative accuracy of the significant test parameters as described by the area under the curve (AUC) and to calculate the sensitivity and specificity of each parameter. There were no differences between control and SKC groups in any regional OCT epithelial thickness parameter. Among relational epithelial thickness metrics, only superonasal - inferotemporal (SN-IT) value differences reached statistical significance between control and SKC groups (-0.81 μm versus 0.41 μm), but this metric still showed limited performance in differentiating groups (AUROC = 0.68). Most stromal thickness values were significantly different between SKC and controls. Epithelial thickness patterns were not effective as a primary metric to identify subclinical keratoconus. Scheimpflug metrics and regional stromal thickness values significantly outperformed epithelial metrics in differentiating both SKC and KC eyes from controls. Epithelial mapping metrics thus appear significantly less sensitive than predicted for subclinical keratoconus detection in early disease manifestations.

13 March 2025 in American Journal of Ophthalmology
Verified
Journal Article
Open access
JRJ. Bradley Randleman
J. Bradley Randleman
BSBianca N. Susanna
Bianca N. Susanna
BHBassel Hammoud
Bassel Hammoud
BDBarbara A.L. Dutra
Barbara A.L. Dutra
GSGiuliano Scarcelli
Giuliano Scarcelli
DKDouglas D. Koch
Douglas D. Koch
To evaluate the consensus agreements reached in the Global Consensus on Keratoconus and Ectatic Diseases project for subclinical keratoconus, specifically that posterior corneal elevation abnormalities must be present to diagnose mild or subclinical keratoconus. Literature review. Database review (PubMed) was performed on January 2, 2024, to identify studies evaluating the ability of posterior corneal surface metrics to identify subclinical keratoconus using the following search terms: posterior corneal elevation; keratoconus screening; corneal ectasia; subclinical keratoconus; keratoconus suspect; and asymmetric keratoconus. Articles were included for final analysis if they evaluated the ability of the posterior corneal surface to identify subclinical keratoconus compared to anterior corneal surface and/or thickness metrics and reported area under the receiver operating curve (AUROC) data for multiple variables to allow for metric comparison. Metrics evaluated in each manuscript were categorized as anterior surface, thickness, or posterior surface. The relative discriminative performance of anterior surface (A), thickness (T), posterior surface (P), and the multimetric D score (D) metrics were evaluated based on AUROC, sensitivity, and specificity in differentiating subclinical keratoconus from normal controls were evaluated. There were 29 articles identified that met the inclusion criteria and were evaluated. In intrastudy comparison, anterior surface metrics (37.9%) and thickness metrics (39.2%) performed best at differentiating subclinical keratoconus from normal corneas, while only 4 out of 29 studies (13.8%) reported posterior metrics outperforming all metrics. In the subgroup analysis including the multimetric D score (n = 15), anterior surface metrics performed best (33.3%), followed by the D score (26.7%). In this D subgroup, no paper reported superior posterior metric performance. In aggregate, posterior corneal surface metrics performed worse than anterior corneal and thickness metrics in differentiating subclinical keratoconic eyes from normal controls. These results demonstrate a lack of evidence to support the consensus claim that posterior elevation abnormalities must be present to diagnose subclinical keratoconus.

19 August 2022 in Human Resources for Health
Verified
Journal Article
Open access
PDF file
BHBassel Hammoud
Bassel Hammoud
ASAline Semaan
Aline Semaan
IEImad H. Elhajj
Imad H. Elhajj
LBLenka Benova
Lenka Benova
Background: Maternal and newborn healthcare providers are essential professional groups vulnerable to physical and psychological risks associated with the COVID-19 pandemic. This study uses machine learning algorithms to create a predictive tool for maternal and newborn healthcare providers’ perception of being safe in the workplace globally during the pandemic. Methods: We used data collected between 24 March and 5 July 2020 through a global online survey of maternal and newborn healthcare providers. The questionnaire was available in 12 languages. To predict healthcare providers’ perception of safety in the workplace, we used features collected in the questionnaire, in addition to publicly available national economic and COVID-19-related factors. We built, trained and tested five machine learning models: Support Vector Machine (SVM), Random Forest (RF), XGBoost, CatBoost and Artificial Neural Network (ANN) for classification and regression. We extracted from RF models the relative contribution of features in output prediction. Results: Models included data from 941 maternal and newborn healthcare providers from 89 countries. ML models performed well in classification and regression tasks, whereby RF had 82% cross-validated accuracy for classification, and CatBoost with 0.46 cross-validated root mean square error for regression. In both classification and regression, the most important features contributing to output prediction were classified as three themes: (1) information accessibility, clarity and quality; (2) availability of support and means of protection; and (3) COVID-19 epidemiology. Conclusion: This study identified salient features contributing to maternal and newborn healthcare providers perception of safety in the workplace. The developed tool can be used by health systems globally to allow real-time learning from data collected during a health system shock. By responding in real-time to the needs of healthcare providers, health systems could prevent potential negative consequences on the quality of care offered to women and newborns.

16 March 2022 in Neurosurgery
Verified
Journal Article
Closed access
ASAhmad Sweid
Ahmad Sweid
KNKareem El Naamani
Kareem El Naamani
RARawad Abbas
Rawad Abbas
RSRobert M. Starke
Robert M. Starke
KBKhodr Badih
Khodr Badih
PJPascal Jabbour
Pascal Jabbour
BACKGROUND: The anterior communicating artery (AcoA) is the most common location for intracranial aneurysms. OBJECTIVE: To present occlusion outcomes, complication rate, recurrence rate, and predictors of recurrence in a large cohort with AcoA aneurysms treated primarily with endosaccular embolization. We also attempt to present data on the most effective treatment modality for recurrent AcoA aneurysms. METHODS: This is a retrospective, single-center study, reviewing the outcomes of 463 AcoA aneurysms treated endovascularly between 2003 and 2018. RESULTS: The study cohort consisted of 463 patients. Adequate immediate occlusion was achieved in 418 (90.3%). Independent functional status at discharge was observed in 269 patients (58.0%), and the mortality rate was 6.8% (31). At 6 months, adequate occlusion was achieved in 418 (90.4%). Of all the patients, recurrence was observed in 101 cases (21.8%), and of those, 98 (22.4%) underwent retreatment. The combined frequency of retreatment for the coiling group was 42.4%, which was significantly higher than the 0 incident of retreatment in the clipping group (P < .0001). Among the retreatment cohort, there was a significantly higher subsequent retreatment rate in the endovascular group (0% in the clipping group vs 42.4% in the endovascular group, P < .0001). CONCLUSION: Coiling with and without stent/balloon assistance is a relatively safe and effective modality for the treatment of AcoA aneurysms; however, in the setting of recurrence, microsurgical reconstruction leads to improved outcomes regarding durable occlusion, thus avoiding the potential for multiple interventions in the future.

27 November 2024 in American Journal of Ophthalmology
Verified
Journal Article
Open access
SAShady Awwad
Shady Awwad
BHBassel Hammoud
Bassel Hammoud
Jad F. AssafJad F. Assaf
Jad F. Assaf
LALara Asroui
Lara Asroui
JRJames Bradley Randleman
James Bradley Randleman
SEShadi Elbassuoni
Shadi Elbassuoni
To develop and validate a pachymetry-based machine learning (ML) index for differentiating keratoconus, keratoconus suspect, and normal corneas. Development and validation of an ML diagnostic algorithm. This retrospective study included 349 eyes of 349 patients with normal, frank keratoconus (KC), and KC suspect (KCS) corneas. KCS corneas included topographically/tomographically normal (TNF) and borderline fellow eyes (TBF) of patients with asymmetric KC. Six parameters were derived from the corneal thickness progression map on the Galilei Dual Scheimpflug-Placido system and fed into a machine-learning algorithm to create the Thickness Speed Progression Index. The model was trained with 5-fold cross-validation using a random search over 7 different ML algorithms, and the best model and hyperparameters were selected. A total of 133 normal eyes, 141 KC eyes, and 75 KCS eyes, subdivided into 34 TNF and 41 TBF eyes, were included. In experiment 1 (normal and KC), the best model (Random Forest) achieved an accuracy of 100% and area under the receiver operating characteristic (AUROC) of 1.00 for both normal and KC groups. In experiment 2 (normal, KCS, and KC), the model achieved an overall accuracy of 91%, and AUROC curves of 0.93, 0.83, and 0.99 in detecting normal, KCS, and KC corneas respectively. In experiment 3 (normal, TNF, TBF, and KC), the model achieved an accuracy of 87% with AUROC curves of 0.91, 0.60, 0.77, and 0.94 for normal, TNF, TBF, and KC corneas, respectively. Using data solely based on pachymetry, ML algorithms such as the Thickness Speed Progression Index are able to discriminate normal corneas from KC and KCSs corneas with reasonable accuracy.

26 February 2026 in American Journal of Ophthalmology
Verified
Journal Article
Open access
HZHongyuan Zhang
Hongyuan Zhang
BHBassel Hammoud
Bassel Hammoud
BSBianca N. Susanna
Bianca N. Susanna
BDBarbara A.L. Dutra
Barbara A.L. Dutra
GSGiuliano Scarcelli
Giuliano Scarcelli
JRJ. Bradley Randleman
J. Bradley Randleman
To compare the diagnostic efficacy of motion-tracking (MT) Brillouin microscopy with multimodal corneal imaging for keratoconus suspect (KCS) identification. Prospective, cross-sectional diagnostic evaluation. There were 56 eyes from 56 patients evaluated, including 28 eyes from 28 bilaterally normal control patients and 28 eyes from 28 keratoconus suspect patients. All patients underwent MT Brillouin microscopy using a custom-built device, Scheimpflug tomography, anterior segment optical coherence tomography (AS-OCT), and Corneal Visualization Scheimpflug Technology (Corvis ST). MT Brillouin microscopy data included mean (MTB-mean) and focal minimum (MTB-min) values within the anterior plateau region. The sensitivity, specificity, and area under the receiver operating characteristic curves (AUROC) were calculated for variables from all modalities. No significant demographic differences were found between groups except thinnest corneal thickness (556 μm Control vs 526 μm KCS; P < .001). MT Brillouin metrics MTB-min (AUC = 0.999, Sensitivity 100%, Specificity 96%) and MTB-mean (AUC 0.981, Sensitivity 93%, Specificity 100%) outperformed all other multimodal imaging metrics in KCS identification and group differentiation. MTB-min significantly outperformed all multimodal metrics, including the Corvis ST Tomographic and Biomechanical Index (TBI) (AUC 0.906, P = .018), Pentacam Random Forest Index (PRFI) (AUC 0.870, P = .005), Keratoconus Index (KI) (AUC 0.873, P = .005), and Index of Height Decentration (IHD) (AUC 0.859, P = .005). The best epithelial metric, Epi 5 mm ST-IN, performed poorly in group differentiation (AUC = 0.641). Motion-tracking Brillouin microscopy metrics effectively identified focal corneal weakening in keratoconus suspects and significantly outperformed all multimodal imaging metrics in differentiating keratoconus suspect eyes from normal controls.