Sara Filipa Teixeira Ribeiro

Sara Filipa Teixeira Ribeiro

Auto-generated profile, based on publicly available information

Sara Filipa Teixeira Ribeiro

Ophthalmology Unit, Department of Senses Organs, Faculty of Medicine, University of Porto, Porto, Portugal; †Department of Ophthalmology, Otorhinolaryngology, and Head and Neck Surgery, School of Medicine of Ribeirão Preto; ‡School of Medicine of Ribeirão Preto and Craniofacial Research Support Center, University of São Paulo, São Paulo, Brazil; §King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia; and ║Johns Hopkins University, Baltimore, Maryland, U.S.A.

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Survey of Ophthalmology
Verified
Journal Article
Closed access
ACAntonio Augusto Velasco Cruz
Antonio Augusto Velasco Cruz
SRSara F.T. Ribeiro
Sara F.T. Ribeiro
DGDenny Marcos Garcia
Denny Marcos Garcia
PAPatricia Mitiko Akaishi
Patricia Mitiko Akaishi
CPCarolina T. Pinto
Carolina T. Pinto

1 March 2014 in Ophthalmic Plastic & Reconstructive Surgery
Verified
Journal Article
Closed access
SWSarah P. F. Wambier
Sarah P. F. Wambier
SRSara F. Ribeiro
Sara F. Ribeiro
DGDenny Marcos Garcia
Denny Marcos Garcia
RBRodrigo R. Brigato
Rodrigo R. Brigato
AMAndre Messias
Andre Messias
ACAntonio A. V. Cruz
Antonio A. V. Cruz
To validate and to report the results of a new inexpensive video-based method to measure upper eyelid motion during spontaneous blinks. Spontaneous blinks were simultaneously recorded in 21 healthy adult subjects for 5 minutes with magnetic search coil (MSC) and a portable video system (VDS) composed by a commercial high-speed camera coupled to a laptop computer and a blue light-emitting diode. Agreement between the 2 methods was assessed using qualitative comparison of the eyelid motion traces and Bland-Altman plots. The blink traces registered with both methods were virtually identical. With the either method, the relationship between amplitude and maximum velocity was well fitted by linear regression with mean r values = 0.81 (MSC) and 0.85 (VDS). Bland-Altman plots showed good agreement between methods. The mean ± SE differences of amplitude (0.06 ± 0.17 mm) and maximum velocity (5.0 ± 3.4 mm/s) were not significant. With the VDS, it was also possible to quantify the horizontal component of the blink movements. The amplitude of the horizontal shift of the eyelid during blinks was 40% of the vertical downward phase of the movement. Blinking kinematics can be precisely measured using a simple and inexpensive video system suitable for clinical settings.

1 January 2012 in Ophthalmic Plastic & Reconstructive Surgery
Verified
Journal Article
Closed access
SRSara F. T. Ribeiro
Sara F. T. Ribeiro
FCFernando Chahud
Fernando Chahud
ACAntonio A. V. Cruz
Antonio A. V. Cruz
Primary granular cell tumor of the orbit is a rare type of neoplasm. The tumor is frequently associated with extraocular muscles, and eye motility limitation is an unavoidable complication after its surgical removal. The objective of the present article is to review the literature on primary granular cell tumors of the orbit and to report a case of this uncommon neoplasia. Granular cell tumor is a benign lesion encountered in most cases (58.3%) in the inferior aspect of the orbit. Extraocular muscle involvement occurs in 72.2% of the patients, and diplopia is present in 77.1% of the cases. The inferior and medial recti are the most affected muscles (38.5% and 26.9%, respectively). Surgical excision is the only modality of treatment, but diplopia persists in 73.3% of the cases. In conclusion, granular cell tumor is a benign lesion but involves a high rate of extraocular muscle morbidity.

1 November 2012 in Ophthalmic Plastic & Reconstructive Surgery
Verified
Journal Article
Closed access
SRSara F. T. Ribeiro
Sara F. T. Ribeiro
GMGherusa H. Milbratz
Gherusa H. Milbratz
DGDenny Marcos Garcia
Denny Marcos Garcia
MDMartin Devoto
Martin Devoto
GNGuilherme H. Neto
Guilherme H. Neto
ACAntonio A. V. M.D. Cruz
Antonio A. V. M.D. Cruz
Purpose: One of the most common problems of the surgical management of Graves upper eyelid retraction is the occurrence of eyelid contour abnormalities. In the present study, the postoperative contour of a large sample of eyelids of patients with Graves orbitopathy was measured. Methods: The postoperative upper eyelid contour of 62 eyes of 43 patients with Graves orbitopathy was subjectively classified by 3 experienced surgeons in 3 categories: poor, fair, and good. The shape of the eyelid contours in each category was then measured with a recently developed custom-made software by measuring multiple midpupil eyelid distances each 15° along the palpebral fissure. The upper eyelid contour of 60 normal subjects was also quantified as a control group. Results: The mean ratio between the sum of the lateral and medial midpupil eyelid distances (lateral/medial ratio) was 1.10 ± 0.11 standard deviation in controls and 1.15 ± 0.13 standard deviation in patients. Postoperatively, the mean midpupil eyelid distance at 90° was 4.16 ± 1.13 mm standard deviation. The distribution lateral/medial ratios of the eyelids judged as having good contours was similar to the distribution of the controls with a modal value centered on the interval between 1.0 and 1.10. The distribution of lateral/medial ratios of the eyelids judged as having poor contour was bimodal, with eyelids with low and high lateral/medial ratios. Low lateral/medial ratios occurred when there was a lateral overcorrection, giving the eyelid a flat or a medial ptosis appearance. High lateral/medial ratios were due to a central or medial overcorrection or a lateral peak maintenance. Conclusions: Postoperative upper eyelid contour abnormalities can be quantified by comparing the sum of multiple midpupil eyelid distances of the lateral and medial sectors of the eyelid. Low and high lateral/medial ratios are anomalous and judged as unpleasant.

1 August 2018 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
FFFernando Faria-Correia
Fernando Faria-Correia
SRSara Ribeiro
Sara Ribeiro
TMTiago Monteiro
Tiago Monteiro
BLBernardo T Lopes
Bernardo T Lopes
MSMarcella Salomao
Marcella Salomao
RARENATO AMBROSIO
RENATO AMBROSIO
PURPOSE: To evaluate the outcomes after topography-guided ablation treatment (T-CAT) for the correction of myopia and myopic astigmatism with photorefractive keratectomy (PRK). METHODS: This was a retrospective, non-comparative case series study of 25 patients (40 eyes) with low to moderate myopia with or without astigmatism who underwent topography-guided custom PRK with the Wave-Light EX500 excimer laser platform (Alcon Laboratories, Inc., Fort Worth, TX). The customized treatment plan was based on Topolyzer Vario topography system (Alcon Laboratories, Inc.) data. The patients were observed for 6 months after the procedure. RESULTS: The surgery significantly reduced the manifest refractive spherical equivalent (MRSE), sphere, and cylinder ( P < .05) at 6 months of follow-up. Compared with the preoperative corrected distance visual acuity (CDVA), 8 (20%) and 10 (25%) of 40 eyes gained one or more lines of postoperative uncorrected distance visual acuity at 3 and 6 months, respectively. Only 1 eye presented loss of one line of CDVA at 6 months postoperatively, which was due to delayed epithelial healing. Ten patients (15 eyes) reported symptoms related to dry eye and the vision of 21 patients (17 eyes) fluctuated during the first month. CONCLUSIONS: The T-CAT custom PRK procedure provided good early outcomes for treating patients with low to moderate myopia with or without astigmatism. [ J Refract Surg. 2018;34(8):541–546.]

1 January 2013 in Ophthalmic Plastic & Reconstructive Surgery
Verified
Journal Article
Closed access
SRSara Filipa Teixeira Ribeiro
Sara Filipa Teixeira Ribeiro
GMGherusa Helena Milbratz
Gherusa Helena Milbratz
DGDenny Marcos Garcia
Denny Marcos Garcia
VFVitor Leal Fernandes
Vitor Leal Fernandes
ARAmândio Rocha-Sousa
Amândio Rocha-Sousa
ACAntonio Augusto Velasco Cruz
Antonio Augusto Velasco Cruz
Purpose: To determine the location of contour abnormalities in Graves upper eyelid retraction. Methods: Multiple midpupil angular eyelid distances of 75 upper eyelids of 55 patients (mean age = 41.7 ± 13.3 SD years) in the inactive phase of Graves orbitopathy were measured with a recently developed custom-made software. Sixty eyelids of 60 normal subjects were also measured as a control group. A contour peak was defined by the highest midpupil angular eyelid distance normalized (divided) by the superior limit of normality (mean + 2SD). Results: In 45 eyelids (60%), the peaks were lateral between 120° and 150°. For high levels of retraction, the peaks tended to be centrally located with a substantial number of medial deformities (30 eyelids). Although the lateral and medial peaks were not affected by exophthalmometry, there was a statistically significant increase of medial peaks when midpupil eyelid distance was greater than 6.75 mm (χ2 = 5.20, p = 0.02). Conclusions: Lateral contour abnormalities are more frequent than medial deformities. With minor degrees of retraction, there is a predominance of lateral peaks. With higher degrees of retraction, the number of medial abnormalities is similar to the lateral ones.