Marcella Salomao

Dr. Marcella Salomao

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
MSMarcella Salomao
Marcella Salomao
AHAna Luisa Hofling-Lima
Ana Luisa Hofling-Lima
LELouise Pellegrino Gomes Esporcatte
Louise Pellegrino Gomes Esporcatte
BLBernardo T Lopes
Bernardo T Lopes
Riccardo VinciguerraRiccardo Vinciguerra
Riccardo Vinciguerra
RARENATO AMBROSIO
RENATO AMBROSIO
Purpose: To review the role of corneal biomechanics for the clinical evaluation of patients with ectatic corneal diseases. Methods: A total of 1295 eyes were included for analysis in this study. The normal healthy group (group N) included one eye randomly selected from 736 patients with healthy corneas, the keratoconus group (group KC) included one eye randomly selected from 321 patients with keratoconus. The 113 nonoperated ectatic eyes from 125 patients with very asymmetric ectasia (group VAE-E), whose fellow eyes presented relatively normal topography (group VAE-NT), were also included. The parameters from corneal tomography and biomechanics were obtained using the Pentacam HR and Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). The accuracies of the tested variables for distinguishing all cases (KC, VAE-E, and VAE-NT), for detecting clinical ectasia (KC + VAE-E) and for identifying abnormalities among the VAE-NT, were investigated. A comparison was performed considering the areas under the receiver operating characteristic curve (AUC; DeLong’s method). Results: Considering all cases (KC, VAE-E, and VAE-NT), the AUC of the tomographic-biomechanical parameter (TBI) was 0.992, which was statistically higher than all individual parameters (DeLong’s; p < 0.05): PRFI- Pentacam Random Forest Index (0.982), BAD-D- Belin -Ambrosio D value (0.959), CBI -corneal biomechanical index (0.91), and IS Abs- Inferior-superior value (0.91). The AUC of the TBI for detecting clinical ectasia (KC + VAE-E) was 0.999, and this was again statistically higher than all parameters (DeLong’s; p < 0.05): PRFI (0.996), BAD-D (0.995), CBI (0.949), and IS Abs (0.977). Considering the VAE-NT group, the AUC of the TBI was 0.966, which was also statistically higher than all parameters (DeLong’s; p < 0.05): PRFI (0.934), BAD- D (0.834), CBI (0.774), and IS Abs (0.677). Conclusions: Corneal biomechanical data enhances the evaluation of patients with corneal ectasia and meaningfully adds to the multimodal diagnostic armamentarium. The integration of biomechanical data and corneal tomography with artificial intelligence data augments the sensitivity and specificity for screening and enhancing early diagnosis. Besides, corneal biomechanics may be relevant for determining the prognosis and staging the disease.

3 November 2023 in Eye and Vision
Verified
Journal Article
Open access
PDF file
RARENATO AMBROSIO
RENATO AMBROSIO
MSMarcella Salomao
Marcella Salomao
LBLorena Barros
Lorena Barros
JFJoão Batista R. da Fonseca Filho
João Batista R. da Fonseca Filho
JGJaime Guedes
Jaime Guedes
LELouise Pellegrino Gomes Esporcatte
Louise Pellegrino Gomes Esporcatte
Different diagnostic approaches for ectatic corneal diseases (ECD) include screening, diagnosis confirmation, classification of the ECD type, severity staging, prognostic evaluation, and clinical follow-up. The comprehensive assessment must start with a directed clinical history. However, multimodal imaging tools, including Placido-disk topography, Scheimpflug three-dimensional (3D) tomography, corneal biomechanical evaluations, and layered (or segmental) tomography with epithelial thickness by optical coherence tomography (OCT), or digital very high-frequency ultrasound (dVHF-US) serve as fundamental complementary exams for measuring different characteristics of the cornea. Also, ocular wavefront analysis, axial length measurements, corneal specular or confocal microscopy, and genetic or molecular biology tests are relevant for clinical decisions. Artificial intelligence enhances interpretation and enables combining such a plethora of data, boosting accuracy and facilitating clinical decisions. The applications of diagnostic information for individualized treatments became relevant concerning the therapeutic refractive procedures that emerged as alternatives to keratoplasty. The first paradigm shift concerns the surgical management of patients with ECD with different techniques, such as crosslinking and intrastromal corneal ring segments. A second paradigm shift involved the quest for identifying patients at higher risk of progressive iatrogenic ectasia after elective refractive corrections on the cornea. Beyond augmenting the sensitivity to detect very mild (subclinical or fruste) forms of ECD, ectasia risk assessment evolved to characterize the inherent susceptibility for ectasia development and progression. Furthermore, ectasia risk is also related to environmental factors, including eye rubbing and the relational impact of the surgical procedure on the cornea.

23 April 2023 in Vision
Verified
Journal Article
Open access
PDF file
RBRodrigo Brazuna
Rodrigo Brazuna
RARuiz S. Alonso
Ruiz S. Alonso
MSMarcella Salomao
Marcella Salomao
BFBruno F. Fernandes
Bruno F. Fernandes
RARENATO AMBROSIO
RENATO AMBROSIO
Biomechanics is a branch of biophysics that deals with mechanics applied to biology. Corneal biomechanics have an important role in managing patients with glaucoma. While evidence suggests that patients with thin and stiffer corneas have a higher risk of developing glaucoma, it also influences the accurate measurement of intraocular pressure. We reviewed the pertinent literature to help increase our understanding of the biomechanics of the cornea and other ocular structures and how they can help optimize clinical and surgical treatments, taking into consideration individual variabilities, improve the diagnosis of suspected patients, and help monitor the response to treatment.

26 July 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Ahmed AbassAhmed Abass
Ahmed Abass
BLBernardo T Lopes
Bernardo T Lopes
AEAshkan Eliasy
Ashkan Eliasy
MSMarcella Salomao
Marcella Salomao
RWRichard Wu
Richard Wu
Ahmed ElsheikhAhmed Elsheikh
Ahmed Elsheikh
To present a three-dimensional non-parametric method for detecting scleral asymmetry using corneoscleral topography data that are free of edge-effect artefacts. The study included 88 participants aged 23 to 65 years (37.7±9.7), 47 women and 41 men. The eye topography data were exported from the Eye Surface Profiler software in MATLAB binary data container format then processed by custom built MATLAB codes entirely independent from the profiler software. Scleral asymmetry was determined initially from the unprocessed topography before being determined again after removing the edge-effect noise. Topography data were levelled around the limbus, then edge-effect was eliminated using a robust statistical moving median technique. In addition to comparing raw elevation data, scleral elevation was also compared through fitting a sphere to every single scleral surface and determining the relative elevation from the best-fit sphere reference surface. When considering the averaged raw topography elevation data in the scleral section of the eye at radius 8 mm, the average raw elevations of the right eyes’ sclera were -1.5±1.77, -1.87±2.12, -1.36±1.82 and -1.57±1.87 mm. In the left eyes at the same radius the average raw elevations were -1.62±1.78, -1.82±2.07, -1.28±1.76 and -1.68±1.93 mm. While, when considering the average raw elevation of the sclera after removing the edge effect, the average raw elevations of the right eyes were -3.71±0.25, -4.06±0.23, -3.95±0.19 and -3.95±0.23 mm. In the left eyes at the same radius the average raw elevations were -3.71±0.19, -3.97±0.22, -3.96±0.19 and -3.96±0.18 mm in the nasal, temporal, superior and inferior sides respectively. Maximum raw elevation asymmetry in the averaged scleral raw elevation was 1.6647±0.9015 mm in right eyes and 1.0358±0.6842 mm in left eyes, both detected at -38° to the nasal side. Best-fit sphere-based relative elevation showed that sclera is more elevated in three main meridians at angles -40°, 76°, and 170° in right eyes and -40°, 76°, and 170° in left eyes, all measured from the nasal meridian. Maximum recorded relative elevation asymmetries were 0.0844±0.0355 mm and 0.068±0.0607 mm at angular positions 76° and 63.5° for right and left eyes in turn. It is not possible to use corneoscleral topography data to predict the scleral shape without considering a method of removing the edge-effect from the topography data. The nasal side of the sclera is higher than the temporal side, therefore, rotationally symmetric scleral contact lenses are more likely to be translated towards the temporal side. The scleral shape is best described by levelled raw elevation rather than relative elevation.

1 August 2018 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
FFFernando Faria-Correia
Fernando Faria-Correia
SRSara Ribeiro
Sara Ribeiro
TMTiago Monteiro
Tiago Monteiro
BLBernardo T Lopes
Bernardo T Lopes
MSMarcella Salomao
Marcella Salomao
RARENATO AMBROSIO
RENATO AMBROSIO
PURPOSE: To evaluate the outcomes after topography-guided ablation treatment (T-CAT) for the correction of myopia and myopic astigmatism with photorefractive keratectomy (PRK). METHODS: This was a retrospective, non-comparative case series study of 25 patients (40 eyes) with low to moderate myopia with or without astigmatism who underwent topography-guided custom PRK with the Wave-Light EX500 excimer laser platform (Alcon Laboratories, Inc., Fort Worth, TX). The customized treatment plan was based on Topolyzer Vario topography system (Alcon Laboratories, Inc.) data. The patients were observed for 6 months after the procedure. RESULTS: The surgery significantly reduced the manifest refractive spherical equivalent (MRSE), sphere, and cylinder ( P < .05) at 6 months of follow-up. Compared with the preoperative corrected distance visual acuity (CDVA), 8 (20%) and 10 (25%) of 40 eyes gained one or more lines of postoperative uncorrected distance visual acuity at 3 and 6 months, respectively. Only 1 eye presented loss of one line of CDVA at 6 months postoperatively, which was due to delayed epithelial healing. Ten patients (15 eyes) reported symptoms related to dry eye and the vision of 21 patients (17 eyes) fluctuated during the first month. CONCLUSIONS: The T-CAT custom PRK procedure provided good early outcomes for treating patients with low to moderate myopia with or without astigmatism. [ J Refract Surg. 2018;34(8):541–546.]

2 December 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
LELouise Pellegrino Gomes Esporcatte
Louise Pellegrino Gomes Esporcatte
MSMarcella Salomao
Marcella Salomao
ANAlexandre Batista da Costa Neto
Alexandre Batista da Costa Neto
AMAydano Machado
Aydano Machado
BLBernardo T. Lopes
Bernardo T. Lopes
RARENATO AMBROSIO
RENATO AMBROSIO
There are different fundamental diagnostic strategies for patients with ectatic corneal diseases (ECDs): screening, confirmation of the diagnosis, classification of the type of ECD, severity staging, prognostic assessment, and clinical follow-up. The conscious application of such strategies enables individualized treatments. The need for improved diagnostics of ECD is related to the advent of therapeutic refractive procedures that are considered prior to keratoplasty. Among such less invasive procedures, we include corneal crosslinking, customized ablations, and intracorneal ring segment implantation. Besides the paradigm shift in managing patients with ECD, enhancing the sensitivity to detect very mild forms of disease, and characterizing the inherent susceptibility for ectasia progression, became relevant for identifying patients at higher risk for progressive iatrogenic ectasia after laser vision correction (LVC). Moreover, the hypothesis that mild keratoconus is a risk factor for delivering a baby with Down’s syndrome potentially augments the relevance of the diagnostics of ECD. Multimodal refractive imaging involves different technologies, including Placido-disk corneal topography, Scheimpflug 3-D tomography, segmental or layered tomography with layered epithelial thickness using OCT (optical coherence tomography), and digital very high-frequency ultrasound (VHF-US), and ocular wavefront. Corneal biomechanical assessments and genetic and molecular biology tests have translated to clinical measurements. Artificial intelligence allows for the integration of a plethora of clinical data and has proven its relevance in facilitating clinical decisions, allowing personalized or individualized treatments.