Diane-Perle Sadik

Diane-Perle Sadik

Auto-generated profile, based on publicly available information

Diane-Perle Sadik

Electrical Power and Energy Systems, KTH, 7655 Stockholm Sweden

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2015 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
JCJuan Colmenares
Juan Colmenares
DPDimosthenis Peftitsis
Dimosthenis Peftitsis
JRJacek Rabkowski
Jacek Rabkowski
DSDiane-Perle Sadik
Diane-Perle Sadik
GTGeorg Tolstoy
Georg Tolstoy
HNHans-Peter Nee
Hans-Peter Nee
This paper presents the design process of a 312-kVA three-phase silicon carbide inverter using ten parallel-connected metal-oxide-semiconductor field-effect-transistor power modules in each phase leg. The design processes of the gate-drive circuits with short-circuit protection and power circuit layout are also presented. Measurements in order to evaluate the performance of the gate-drive circuits have been performed using a double-pulse setup. Moreover, electrical and thermal measurements in order to evaluate the transient performance and steady-state operation of the parallel-connected power modules are shown. Experimental results showing proper steady-state operation of the power converter are also presented. Taking into account measured data, an efficiency of approximately 99.3% at the rated power has been measured for the inverter.

13 February 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
DSDiane-Perle Sadik
Diane-Perle Sadik
JCJuan Colmenares
Juan Colmenares
JLJang-Kwon Lim
Jang-Kwon Lim
MBMietek Holtryd BAKOWSKI
Mietek Holtryd BAKOWSKI
HNHans-Peter Nee
Hans-Peter Nee
The temperature evolution during a short-circuit fault in the dies of three different Silicon Carbide 1200-V power devices is presented. Transient electro-thermal simulations were performed based on the reconstructed structure of commercially available devices. The simulations reveal the location of the hottest point in each device. The nonisothermal electrical analysis supports the necessity to turn OFF short-circuit events rapidly to protect the immunity of the device after a fault. The analysis also reveal differences in delay required to turn OFF devices depending on their type. A thorough analysis of the temperature rise in the die of the SiC MOSFET device is also presented, where the maximum temperature with regards to different fault cases and circuit characteristics is presented. The impact of the gate resistance, circuit inductance, detection time, drain-source voltage, and gate-source voltage are considered.