Hans-Peter Nee

Hans-Peter Nee

Auto-generated profile, based on publicly available information

Hans-Peter Nee

Department of Electric Power and Energy Systems, KTH Royal Institute of Technology, Stockholm, Sweden

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2014 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
KIKalle Ilves
Kalle Ilves
FTFranz Taffner
Franz Taffner
SNStaffan Norrga
Staffan Norrga
AAAntonios Antonopoulos
Antonios Antonopoulos
LHLennart Harnefors
Lennart Harnefors
HNHans-Peter Nee
Hans-Peter Nee
In modular multilevel converters, there is a tradeoff between the switching frequency and the voltage ripple in the submodule capacitors. The reason for this is that it becomes increasingly difficult to balance the capacitor voltages when the switching frequency is reduced. This paper presents a new submodule circuit, which improves the balancing of the capacitor voltages at low switching frequencies. The proposed submodule circuit consists of two capacitors and eight switches, forming a three-level submodule. Ideally, the voltage and current ratings of the switches can be chosen such that the combined power rating of the semiconductors is the same as for the equivalent solution with conventional half-bridge submodules. The proposed submodule circuit provides the possibility of connecting the two capacitors in parallel when the intermediate voltage level is used. This will reduce the capacitor voltage ripple, especially at low switching frequencies, and thus, allow for a reduction of the size, weight, and cost of the submodule capacitors. The proposed submodule circuit is validated by both simulations and experimental results. It is found that the parallel connection of the submodule capacitors will, in fact, significantly improve the balancing of the capacitor voltages.

14 August 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
EVErik Velander
Erik Velander
GBGeorg Bohlin
Georg Bohlin
ASAsa Sandberg
Asa Sandberg
TWThomas Wiik
Thomas Wiik
FBFredrik Botling
Fredrik Botling
HNHans-Peter Nee
Hans-Peter Nee
In this paper, a novel dv/dt filter is presented targeted for 100-kW to 1-MW voltage source converters using silicon carbide (SiC) power devices. This concept uses the stray inductance between the power device and the converter output as a filter component in combination with an additional small RC-link. Hence, a lossy, bulky, and costly filter inductor is avoided and the resulting output dv/dt is limited to 5-10 kV/μs independent of the output current and switching speed of the SiC devices. As a consequence, loads with dv/dt constraints, e.g., motor drives can be fed from SiC devices enabling full utilization of their high switching speed. Moreover, a filter-model is proposed for the selection of filter component values for a certain dv/dt requirement. Finally, results are shown using a 300-A 1700-V SiC metal-oxide-semiconductor field-effect transistor (MOSFET). These results show that the converter output dv/dt can be limited to 7.5 kV/μs even though values up to 47 kV/μs were measured across the SiC MOSFET module. Hence, the total switching losses, including the filter losses, are verified to be three times lower compared to when the MOSFET dv/dt was slowed down by adjusting the gate driver.

12 February 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
HZHongyang Zhang
Hongyang Zhang
XWXiongfei Wang
Xiongfei Wang
LHLennart Harnefors
Lennart Harnefors
HGHong Gong
Hong Gong
JHJean-Philippe Hasler
Jean-Philippe Hasler
HNHans-Peter Nee
Hans-Peter Nee
Converter-grid interaction is of great interest in a weak-grid condition. This paper presents a single-input single-output open-loop transfer function for the stability analysis of grid-connected voltage-source converters. Differing from the conventional input impedance method and the eigenvalue analysis, an alternative multi-input multioutput closed-loop system is developed in the paper and it eventually yields a single-input single-output open-loop transfer function. This enables the application of a single Nyquist curve for analyzing the overall system stability. The model is validated against time-domain simulations as well as experimental results showing excellent accuracy for predicting the system stability.

14 July 2015 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
JCJuan Colmenares
Juan Colmenares
DPDimosthenis Peftitsis
Dimosthenis Peftitsis
JRJacek Rabkowski
Jacek Rabkowski
DSDiane-Perle Sadik
Diane-Perle Sadik
GTGeorg Tolstoy
Georg Tolstoy
HNHans-Peter Nee
Hans-Peter Nee
This paper presents the design process of a 312-kVA three-phase silicon carbide inverter using ten parallel-connected metal-oxide-semiconductor field-effect-transistor power modules in each phase leg. The design processes of the gate-drive circuits with short-circuit protection and power circuit layout are also presented. Measurements in order to evaluate the performance of the gate-drive circuits have been performed using a double-pulse setup. Moreover, electrical and thermal measurements in order to evaluate the transient performance and steady-state operation of the parallel-connected power modules are shown. Experimental results showing proper steady-state operation of the power converter are also presented. Taking into account measured data, an efficiency of approximately 99.3% at the rated power has been measured for the inverter.

23 January 2018 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
ARArash Edvin Risseh
Arash Edvin Risseh
HNHans-Peter Nee
Hans-Peter Nee
CGChristophe Goupil
Christophe Goupil
A considerable part of the fuel energy in vehicles never reaches the wheels and entirely converts to waste heat. In a heavy duty vehicle (HDV), the heat power that escapes from the exhaust system may reach 170 kW. The waste heat can be converted into useful electrical power using a thermoelectric generator (TEG). During the last decades, many studies on the electrical power conditioning system of TEGs have been conducted. However, there is a lack of studies evaluating the electrical instrumentation, the impact of the converter efficiency, and the TEG arrangement on a real large-scale TEG on-board a drivable vehicle. In this paper, the most important parameters for designing electrical power conditioning systems for two TEGs, developed for a real-scale HDV as well as experimental results demonstrating the recovered electrical power, are presented. Eight synchronous interleaved step-down converters with 98% efficiency with a perturb and observe maximum power point tracker was developed and tested for this purpose. The power conditioning system was communicating with the on-board computers through the controller area network and reported the status of the TEGs and the recovered electrical power. The maximum recovered electrical power from the TEGs reached 1 kW which was transmitted to the electrical system of the vehicle, relieving the internal combustion engine.

24 June 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
MAMohsen Asoodar
Mohsen Asoodar
MNMehrdad Nahalparvari
Mehrdad Nahalparvari
CDChrister Danielsson
Christer Danielsson
RSRasmus Söderström
Rasmus Söderström
HNHans-Peter Nee
Hans-Peter Nee
This article presents an online health monitoring scheme for dc capacitors in modular multilevel converters (MMCs). The health monitoring algorithm is based on detecting changes in the dc capacitance value over time. The proposed algorithm only utilizes measurements that are typically available in flexible alternating current transmission systems and high-voltage direct current applications. Hence, in the proposed estimation method, no additional sensors are used. The estimation scheme considers the presence of noise in voltage and current measurements, and utilizes a recursive least square estimator in conjunction with a special low-pass filter to minimize the estimation errors. Simulation results of a hardware replica, as well as experimental results on a low-power MMC prototype show that the proposed scheme can identify the dc-link capacitance value with a maximum error of 1%.