1 August 2011 in Journal of Dental Research
Osseointegrated implants often fail because of excessive masticatory forces that cause extremely large stresses in bone tissue. We hypothesized that a proper dental implant could be selected by comparing the ultimate masticatory forces of a wide range of commercially available implants. We determined ultimate oblique masticatory forces for different cylindrical implants, taking into consideration the biomechanical correlation between implant dimensions and stresses in supporting bone. For this purpose, we used the finite element (FE) method and studied von Mises stresses in implant-bone interface areas to evaluate the influence of implant dimensions on stress concentration and on the value of an implant’s ultimate masticatory load. Geometric models of a mandibular segment were generated from computed tomography (CT) images and were analyzed with osseointegrated cylindrical implants. Masticatory forces were applied in their natural direction. All materials were assumed to be linearly elastic and isotropic. Critical point in the peri-implant area of bone was determined. The ultimate value of the masticatory load, which generates ultimate stresses at the critical point, was calculated for each implant. These findings provide correct selection of implant dimensions in clinical cases, because corresponding ultimate values of masticatory force were used as a criterion for assessment of their load-carrying capacity and applicability.
15 May 2012 in Computer Methods in Biomechanics and Biomedical Engineering
Implant dimensions greatly influence load transfer characteristics and the lifetime of a dental system. Excessive stresses at peri-implant area may result in bone failure. Finding the critical point at the implant–bone interface and evaluating the influence of implant diameter-to-length ratio on adjacent bone stresses makes it possible to select implant dimensions. For this, different cylindrical implants were numerically analysed using geometrical models generated from computed tomography images of mandible with osseointegrated implants. All materials were assumed to be linearly elastic and isotropic. Masticatory load was applied in its natural direction, oblique to occlusal plane. Maximum von Mises stresses were located around the implant neck at the critical point of its intersection with the plane of loading and were functions of implant diameter-to-length ratio. It was demonstrated that there exists a certain spectrum of diameter-to-length ratios, which will keep maximum bone stresses at a preset level chosen in accordance with patient's bone strength.
1 January 2013 in AIP Conference Proceedings
19 July 2015 in International Journal of Advanced Mathematical Sciences
This paper presents the investigative study to derive a computational model based on hypersingular integral equations for the pre-Cantor plane-parallel diffraction structure. Such structure consists of finite numbers of the thin impedance strips located in the XY plane. A plane transverse magnetic wave is incident from infinity on considered diffraction structure at an angle and need to find the total field resulting from the scattering. The model which is considered in this work is an approximation of real fractal antennas in two-dimensional case. Pre-fractal properties of grating allow producing the newest antennas for modern mobile devices due to their compact size and broadband properties. The purpose of this work is to develop computer model their structure using parametric representation of hypersingular integral operator, Nystrom method with specific quadrature formulas. The numerical results have been obtained and investigated for pre-Cantor structures for calculating physics characteristics. These results have been compared and analyzed in different mathematical models and softwares.