15 May 2012 in Computer Methods in Biomechanics and Biomedical Engineering
Implant dimensions greatly influence load transfer characteristics and the lifetime of a dental system. Excessive stresses at peri-implant area may result in bone failure. Finding the critical point at the implant–bone interface and evaluating the influence of implant diameter-to-length ratio on adjacent bone stresses makes it possible to select implant dimensions. For this, different cylindrical implants were numerically analysed using geometrical models generated from computed tomography images of mandible with osseointegrated implants. All materials were assumed to be linearly elastic and isotropic. Masticatory load was applied in its natural direction, oblique to occlusal plane. Maximum von Mises stresses were located around the implant neck at the critical point of its intersection with the plane of loading and were functions of implant diameter-to-length ratio. It was demonstrated that there exists a certain spectrum of diameter-to-length ratios, which will keep maximum bone stresses at a preset level chosen in accordance with patient's bone strength.
25 March 2013 in Computer Methods in Biomechanics and Biomedical Engineering
Extreme stresses in surrounding bone are among the most important reasons for implant failure. Bone density (quality) is a variable that plays a decisive role in achieving predictable osseointegration and long-term survival of implants. The magnitudes of ultimate occlusal load, which generate ultimate von Mises stress at the critical point of peri-implant area for the spectrum of implants inserted into mandible with four different bone qualities (Lekholm and Zarb classification), were calculated. Geometric models of mandible segment were generated from computed tomography images and analysed with osseointegrated cylindrical implants of various dimensions. Occlusal loads were applied in their natural direction. All materials were assumed to be linearly elastic and isotropic. The investigation suggests that an implant's ultimate occlusal load indicates its load-carrying capacity. As a result, bone loss can be predicted, and viable implants can be selected by comparing the values of their ultimate occlusal load in different clinical conditions.
8 January 2015 in Computer Methods in Biomechanics and Biomedical Engineering
HWHans-Werner Weisskircher
+1
Dental implant failure is mainly the consequence of bone loss at peri-implant area. It usually begins in crestal bone. Due to this gradual loss, implants cannot withstand functional force without bone overload, which promotes complementary loss. As a result, implant lifetime is significantly decreased. To estimate implant success prognosis, taking into account 0.2 mm annual bone loss for successful implantation, ultimate occlusal forces for the range of commercial cylindrical implants were determined and changes of the force value for each implant due to gradual bone loss were studied. For this purpose, finite element method was applied and von Mises stresses in implant-bone interface under 118.2 N functional occlusal load were calculated. Geometrical models of mandible segment, which corresponded to Type II bone (Lekholm & Zarb classification), were generated from computed tomography images. The models were analyzed both for completely and partially osseointegrated implants (bone loss simulation). The ultimate value of occlusal load, which generated 100 MPa von Mises stresses in the critical point of adjacent bone, was calculated for each implant. To estimate longevity of implants, ultimate occlusal loads were correlated with an experimentally measured 275 N occlusal load (Mericske-Stern & Zarb). These findings generally provide prediction of dental implants success.
5 October 2020 in Clinical Oral Implants Research
Click on the article title to read more.
8 October 2018 in Clinical Oral Implants Research
8 October 2018 in Clinical Oral Implants Research