Igor Linetskiy

Dr. Igor Linetskiy

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 December 2017 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
ILIgor Linetskiy
Igor Linetskiy
VDVladyslav Demenko
Vladyslav Demenko
LLLarysa Linetska
Larysa Linetska
OYOleg Yefremov
Oleg Yefremov

1 August 2011 in Journal of Dental Research
Verified
Journal Article
Closed access
VDVladyslav Demenko
Vladyslav Demenko
ILIgor Linetskiy
Igor Linetskiy
KNK. Nesvit
K. Nesvit
ASA. Shevchenko
A. Shevchenko
Osseointegrated implants often fail because of excessive masticatory forces that cause extremely large stresses in bone tissue. We hypothesized that a proper dental implant could be selected by comparing the ultimate masticatory forces of a wide range of commercially available implants. We determined ultimate oblique masticatory forces for different cylindrical implants, taking into consideration the biomechanical correlation between implant dimensions and stresses in supporting bone. For this purpose, we used the finite element (FE) method and studied von Mises stresses in implant-bone interface areas to evaluate the influence of implant dimensions on stress concentration and on the value of an implant’s ultimate masticatory load. Geometric models of a mandibular segment were generated from computed tomography (CT) images and were analyzed with osseointegrated cylindrical implants. Masticatory forces were applied in their natural direction. All materials were assumed to be linearly elastic and isotropic. Critical point in the peri-implant area of bone was determined. The ultimate value of the masticatory load, which generates ultimate stresses at the critical point, was calculated for each implant. These findings provide correct selection of implant dimensions in clinical cases, because corresponding ultimate values of masticatory force were used as a criterion for assessment of their load-carrying capacity and applicability.

1 January 2008
Verified
Journal Article
Closed access
VSV Seidler
V Seidler
ILIgor Linetskiy
Igor Linetskiy
HHH Hubálková
H Hubálková
HSH Stanková
H Stanková
Roman SmuclerRoman Smucler
Roman Smucler
JMJ Mazánek
J Mazánek

15 May 2012 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
VDVladyslav Demenko
Vladyslav Demenko
ILIgor Linetskiy
Igor Linetskiy
KNK. Nesvit
K. Nesvit
HHH. Hubalkova
H. Hubalkova
VNV. Nesvit
V. Nesvit
ASA. Shevchenko
A. Shevchenko
Implant dimensions greatly influence load transfer characteristics and the lifetime of a dental system. Excessive stresses at peri-implant area may result in bone failure. Finding the critical point at the implant–bone interface and evaluating the influence of implant diameter-to-length ratio on adjacent bone stresses makes it possible to select implant dimensions. For this, different cylindrical implants were numerically analysed using geometrical models generated from computed tomography images of mandible with osseointegrated implants. All materials were assumed to be linearly elastic and isotropic. Masticatory load was applied in its natural direction, oblique to occlusal plane. Maximum von Mises stresses were located around the implant neck at the critical point of its intersection with the plane of loading and were functions of implant diameter-to-length ratio. It was demonstrated that there exists a certain spectrum of diameter-to-length ratios, which will keep maximum bone stresses at a preset level chosen in accordance with patient's bone strength.

1 June 2006 in International Dental Journal
Verified
Journal Article
Closed access
PDF file
HHHana Hubálková
Hana Hubálková
PSPaola La Serna
Paola La Serna
ILIgor Linetskiy
Igor Linetskiy
TDTat’jAna Dostálová
Tat’jAna Dostálová