Paulo Eduardo Maciel Almeida

Paulo Eduardo Maciel Almeida

Auto-generated profile, based on publicly available information

Paulo Eduardo Maciel Almeida

Instituto de Telecomunicações, Departamento de Engenharia Electrotécnica e de Computadores, Universidade de Coimbra, 3030-290, Portugal

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2003 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MMM.R.G. Meireles
M.R.G. Meireles
PAP.E.M. Almeida
P.E.M. Almeida
Marcelo SimoesMarcelo Simoes
Marcelo Simoes
This paper presents a comprehensive review of the industrial applications of artificial neural networks (ANNs), in the last 12 years. Common questions that arise to practitioners and control engineers while deciding how to use NNs for specific industrial tasks are answered. Workable issues regarding implementation details, training and performance evaluation of such algorithms are also discussed, based on a judiciously chronological organization of topologies and training methods effectively used in the past years. The most popular ANN topologies and training methods are listed and briefly discussed, as a reference to the application engineer. Finally, ANN industrial applications are grouped and tabulated by their main functions and what they actually performed on the referenced papers. The authors prepared this paper bearing in mind that an organized and normalized review would be suitable to help industrial managing and operational personnel decide which kind of ANN topology and training method would be adequate for their specific problems.

31 January 2005 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
PAP.E.M. Almeida
P.E.M. Almeida
Marcelo SimoesMarcelo Simoes
Marcelo Simoes
This paper demonstrates an application of the parametric cerebellar model articulation controller (P-CMAC) network - a neural structure derived from Albus' CMAC algorithm and Takagi-Sugeno-Kang parametric fuzzy inference systems. It resembles the original CMAC proposed by Albus in the sense that it is a local network, i.e., for a given input vector, only a few of the networks neurons will be active and will effectively contribute to the corresponding network output. The internal mapping structure is built in such a way that it implements, for each CMAC memory location, one linear parametric equation of the network input strengths. First, a new approach to design neural optimal control (NOC) systems is proposed. Gradient-descent techniques are still used here to adjust network weights, but this approach has many differences when compared to classical error backpropagation algorithm. Then, P-CMAC is used to control the output voltage of a proton exchange membrane fuel cell (PEM-FC), by means of NOC. The proposed control system allows the definition of an arbitrary performance/cost criterion to be maximized/minimized, resulting in an approximated optimal control strategy. Practical results of PEM-FC voltage behavior at different load conditions are shown, to demonstrate the effectiveness of the NOC algorithm.

1 November 2010
Verified
Conference Paper
Closed access
LMLuiz A.O. Martins
Luiz A.O. Martins
FPFlavio L.C. Padua
Flavio L.C. Padua
PAPaulo E.M. Almeida
Paulo E.M. Almeida
This work addresses the problem of automated visual inspection of surface defects on rolled steel, by using Computer Vision and Artificial Neural Networks. In recent years, the increasing throughput in the steel industry has become the visual inspection a critical production bottleneck. In this scenario, to assure a high rolled steel quality, novel sensor-based technologies have been developed. Unlike most common techniques, which are frequently based on manual estimations that lead to significant time and financial constraints, we present an automatic system based on (i) image analysis techniques, such as, Hough Transform to classify three defects with well-defined geometric shapes: welding, clamp and identification hole and (ii) two well-known feature extraction techniques: Principal Component Analysis and Self-Organizing Maps to classify three defects with complex shapes, specifically, oxidation, exfoliation and waveform defect. To demonstrate the effectiveness of our system, we tested it on challenging real-world datasets, acquired in a rolling mill of the steel company ArcelorMittal. The system was successfully validated, achieving overall accuracy of 87% and demonstrating its high potential to be applied in real scenarios.

17 April 2018 in Applied Intelligence
Verified
Journal Article
Closed access
PDF file
CMCarolina Gil Marcelino
Carolina Gil Marcelino
PAPaulo E. M. Almeida
Paulo E. M. Almeida
EWElizabeth F. Wanner
Elizabeth F. Wanner
MBManuel Baumann
Manuel Baumann
MWMarcel Weil
Marcel Weil
VMVladimiro Miranda
Vladimiro Miranda

17 October 2020 in Scientometrics
Verified
Journal Article
Closed access
PDF file
CSCinthia M. Souza
Cinthia M. Souza
MMMagali R. G. Meireles
Magali R. G. Meireles
PAPaulo E. M. Almeida
Paulo E. M. Almeida

1 September 2017
Verified
Conference Paper
Closed access
MBManuel Baumann
Manuel Baumann
JPJens Peters
Jens Peters
MWMarcel Weil
Marcel Weil
CMCarolina Gil Marcelino
Carolina Gil Marcelino
PAPaulo Almeida
Paulo Almeida
EWElizabeth Wanner
Elizabeth Wanner
Battery storage is considered as crucial for the safe operation and design of hybrid micro-grid systems (HMGS) by balancing load and generation from renewable energy sources. However, several battery technologies are available for this purpose, with different greenhouse gas emissions associated with their production. This paper applies a canonical differential evolutionary particle swarm algorithm for optimizing HMGS design and operation. Optimization goals are minimization of electricity costs and loss of power supply probability and maximization of renewable shares. The global warming potential of the obtained HMGS supported by different battery technologies is then determined via life cycle assessment. Results indicate that all the considered battery types lead to environmental benefits when compared with a HMGS without storage. Lithium iron phosphate and sodium nickel chloride batteries show favorable results whereas lead acid and lithium manganese oxide batteries are ranked last.