16 June 2022 in IEEE Transactions on Instrumentation and Measurement
To improve the accuracy of micro-coordinate measuring machines (CMMs) to nanometer scale, numerous hardware improvements have been studied and carried out in recent years, albeit with high costs and application limitations. Error compensation technology through software has also been applied because of its high precision, high efficiency, and low cost. A global volumetric error compensation model on the basis of the Abbe and Bryan principles for micro-CMMs is proposed in this study. The volumetric errors of the general CMMs were also analyzed, and the transmission relationship between the volumetric and geometric errors was established in the proposed model. The parameters in the model including 21 geometric errors and Abbe/Bryan offsets were measured and used to compensate for the volumetric errors. A zero-class gauge block was tested using a micro-CMM based on ISO 10360-2. With the volumetric error compensation, the standard deviations of the length measurements in the different diagonal directions were reduced by more than 65%. Thus, the effectiveness of the proposed method was established. This study provides a general modeling method and compensation techniques of volumetric errors for people involved in accuracy improvement for CMMs and machine tools.
1 June 2022 in IEEE Transactions on Instrumentation and Measurement
Roundness is a kind of form error in geometrical measurement in laboratory and industry and contributes significantly to the uncertainty of the measurement instruments using precision spheres, especially microspheres. A new radius and roundness measurement method for microspheres is proposed in this paper. Using this method, not only can separate different run-out errors from the measuring results, but also can obtain the true radii in different directions of the tested microsphere, which are necessary for the roundness evaluation according to ISO 1101. A new roundness measurement system has also been developed, which is mainly composed of two miniaturized Michelson interferometer (MI) systems, two elastic mechanisms, and a precision rotating stage. Repeated measurements have been performed using a ruby microsphere manufactured by Renishaw Corporation as the reference, which has a claimed diameter and roundness of 700 μm and 130 nm respectively. Experimental results show that the average radius of the tested microsphere is 349.99 μm with a maximum error of 65 nm and an expanded uncertainty of 94.0 nm (k=2). The proposed method and system can be used in the precision contact measurements of parts with micro circular characteristics such as microspheres and micro cylinders.
30 June 2023 in Measurement Science and Technology
The microsphere profile of probe tips has to be measured and compensated to improve the measurement accuracy of micro-coordinate measuring machines (micro-CMMs) to less than several hundred nanometers. A high-precision radius and sphericity measurement method for the microsphere of the CMM probe tip is proposed in this article. Different circumferences of the tested microsphere are measured, and the true radius of any measuring point on the surface can be obtained after separating the runout errors. Then the sphericity of the tested microsphere can be evaluated by the minimum zone sphere method. A corresponding measuring system is developed based on the analysis of the primary error model and mechanical model, and verification experiments are conducted using a ruby microsphere (A-5000-7801, Renishaw Corporation) as the reference, whose claimed diameter and sphericity are 700 µm and 130 nm, respectively. Six groups of repeated experiments are performed, and 18 000 measurement points on 15 circumferences are recorded in each group of experiments. Results show that the average radius of the tested microsphere is 350.003 µm, and the average sphericity error is 208 nm with a standard deviation of 5.3 nm. Finally, the expanded uncertainty of the measurement results of the developed system is calculated as 209 nm (k = 1.96, normal distribution). The proposed method and system can be used in the precision measurements and compensations for probe tips of micro-CMMs and other parts, such as microspheres used in micro-bearings and micro-manufacturing machines.
4 October 2021 in IEEE Transactions on Instrumentation and Measurement
Nonlinear errors, including direct current (DC) offset, lack of quadrature, and unstable amplitude, are inevitable in the sinusoidal waves of interferometry due to unsatisfactory detector system. Precision and possible measuring range of an interferometry are limited by the errors. An analog electronic method to solve the nonlinear errors is proposed in this paper. Preamplifier circuits, DC offset compensation circuits based on a low-pass filter, orthogonalized circuits based on vector operations, and regularized circuits based on automatic gain control (AGC) technology are analyzed, designed, and verified respectively. Using the designed circuits, a polarizing Michelson interferometer (PMI) system has been developed and used to measure a high-precision stage with a stroke of 15 mm and a maximum angular error of 35 arc-sec. Experimental results show that the errors of the sinusoidal waves between 20 Hz and 2 kHz in frequency and between 200 mV and 5 V in amplitude can be reduced effectively by the developed circuits. The expanded uncertainty of the developed PMI system is 47 nm. Further experiments have been carried out on a common guide rail with a length of 600 mm. Experimental results reveal that the tolerable angular error motion of the reflecting mirror of the PMI system is improved from ±68.5 arc-sec to ±274 arc-sec in a measuring distance of 500 mm. The proposed method can be used to reduce the nonlinear errors in sinusoidal wave signal processing fields.
9 November 2021 in IEEE Transactions on Instrumentation and Measurement
In the above article [1] , in Table VI, the unit of “displacement” should be corrected from “mm” to “ $\mu$ m.” The displacement measurement experiments were carried out on a 600-mm-long guide rail; however, we forgot to convert the unit in Table VI.
26 November 2024 in Measurement Science and Technology
Tungsten balls with a diameter of less than 100 μm can function as probe tips for micro-coordinate measuring machines to measure ultraprecise workpieces with complex features. A high-precision measuring system was developed to evaluate the roundness of self-made tungsten ball tips. The system, based on the two-point method, is composed of two oppositely placed interferometers and a turntable. The turntable rotates the tested ball, and the interferometers measure the variation in radius. A new model based on the minimum zone method is proposed to evaluate roundness. The fabrication principle of tungsten balls is introduced and an analysis is conducted on the maximum permissible contact force and bending stress of tungsten ball tips. The elastic mechanism is designed, based on the analysis. A ruby sphere with a sphericity of 130 nm is measured to verify the system’s effectiveness. Repeated experiments are performed for two tungsten ball tips. The results show that the roundness error of tungsten ball-A is between 550.9 and 586.2 nm with a standard deviation of 11.0 nm while tungsten ball-B’s roundness error is between 898.5 and 959.9 nm with a standard deviation of 21.7 nm. The uncertainty is calculated as 144.6 nm. The developed system can stably measure the roundness of tungsten ball tips.