A modified method for the analysis of nicosulfuron, rimsulfuron and prosulfuron was developed and validated by using microwave-assisted extraction (MAE) and ultra-performance liquid chromatography with diode array detection in the ultraviolet region (HPLC-UV-DAD). The most important experimental parameters of extraction procedure and HPLC-UV-DAD technique were optimised in respect to those sulfonylurea herbicides. High recoveries of the microwave-assisted extraction were obtained by using a dichloromethane?acetonitrile mixture (2:1 volume ratio) acidified with acetic acid (0.8 vol.%) with the addition of urea. The mean recoveries at three spiking levels ranged from 97.47 to 98.76% for nicosulfuron, 97.88 to 99.17% for rimsulfuron and from 97.91 to 99.83% for prosulfuron. The limits of detection of nicosulfuron, rimsulfuron and prosulfuron were 0.95, 0.91 and 0.89 ?g kg?1, respectively. The accuracy of the developed method was confirmed by HPLC coupled with tandem mass spectrometry parallel analyses. The developed method was used to investigate the dissipation dynamics of sulfonylurea herbicides in the real field trials in Vojvodina Province, Serbia. The obtained half-lives were 0.05, 0.23 and 0.15 days for recommended dose application of nicosulfuron, rimsulfuron and prosulfuron, respectively. Low residues and short half-life in soil suggested that the risk to sensitive rotational crops after application of those sulfonylurea herbicides is low when they are used in the appropriate dosages.
1 January 2010 in Journal of the Serbian Chemical Society
A sample preparation method based on the simultaneous microwave-assisted extraction-esterification (SMAEE) was developed for the determination of the fatty acid composition of foodstuffs by gas chromatography-mass spectrometry. The proposed sample preparation method was validated by comparison with the reference Soxhlet extraction method followed by derivatisation by ester formation and the same determination step. The fatty acid compositions and the extraction efficiencies obtained using the proposed SMAEE method and the reference method were statistically similar. The results showed that compared to the conventional method, the SMAEE method offered the advantages of short sample preparation time, low consumption of expensive organic solvents and lower energy consumption. This good agreement between results provided by both the SMAEE and the reference method demonstrates the usefulness of the former as a routine method for the treatment of food samples prior to trans fatty analysis.
An experimental study was carried out with the aim of evaluating the quality of the lipid fraction of Serbian biscuits. Total fat contents of the biscuit samples ranged between 10.2% and 24.5%. The saturated, cis-monounsaturated and cis-polyunsaturated fatty acid contents were within the ranges of 18.585.6%, 10.649.9% and 2.713.3% of total fatty acids, respectively. The content of trans fatty acids (TFA) ranged from 0.0% to 42.5% and the mean was 10.2%. In a total of 34 investigated samples, 10 of them were found to be trans - free, 8 contained low level of TFA (under 2%), 4 samples contained between 2 and 10% of TFA, while 12 samples contained very high amounts of TFA (12.042.5%). The results obtained showed a considerable variability in fatty acid composition of biscuits which indicated that different types of fats and oils were used for production of biscuits in Serbia.
1 January 2002 in Journal of the Serbian Chemical Society
The trace amounts of lead in extraction glassware products were determined by potentiometric stripping analysis with constant inverse current in the analytic step (PSA-iR), an electrochemical technique of high sensitivity and selectivity. This paper deals with an investigation which was directed to the effect of a great number of factors on the results of PSA-iR, of lead in glassware, such as the mercury time electrodeposition, the electrolysis potential, the solution stirring rate and the constant inverse current. Linearity of the lead analytical signal was achieved within the range of mass concentrations from 2.5 ?g/dm3 to 4.5 ?g/dm3.Adetection limit of 0.64 ?g/dm3 was obtained, with a reproducibility of 4.14 % expressed as the coefficient of variation. The analyses were carried out using a computerized stripping analyzer of domestic design and manufacture (Faculty of Technology, Novi Sad and "Elektrouniverzal", Leskovac). The accuracy of the method was confirmed by parallel analyses using flameless atomic absorption spectrophotometry as the reference method.
The aim of this study was the investigation of the possibilities of direct determination of calcium, sodium and potassium in the commercial and kombucha-based fermented milk products by flame photometry. Two procedures were used for sample preparation: simple dilution with water (direct method) and extraction with mineral acid. Calcium, sodium and potassium levels determined after mentioned sample preparation methods were compared. The results showed that the differences between the values obtained for the different sample treatment were within the experimental error at the 95% confidence level. Compared to the method based on extraction with mineral acid, the direct method is efficient, faster, simpler, cheaper, and operates according to the principles of Green Chemistry. Consequently, the proposed method for the direct determination of calcium, sodium and potassium could be applied for the rapid routine analysis of the mineral content in the fermented dairy products.
2 April 2019 in Journal of Analytical Methods in Chemistry
The most important experimental parameters of the flow potentiometric stripping analysis (PSA) with oxygen as an oxidant were investigated and optimised. A simple, homemade flow system consisting of glassy carbon tubes, which served as a working and auxiliary electrode, was used. By applying a rest period before the stripping step (the flow stop mode) and by imposing a constant reductive current simultaneously with the interruption of potentiostatic control, significant increase of the flow PSA sensitivity was achieved. In the determination of cadmium and lead, quantitation limits of 0.11 and 0.82 μg/L were obtained. The precision of the method was evaluated in terms of repeatability and reproducibility, with values of relative standard deviation lower than 4.0% for cadmium and 4.2% for lead. This modified technique was applied for simultaneous determination of cadmium and lead in milk, after a simple pretreatment of the samples by dilution and acidification. The method accuracy was confirmed by analysing the certified reference material of skimmed milk powder (ERM-BD151).