Man-Ching Huang

Man-Ching Huang

Auto-generated profile, based on publicly available information

Man-Ching Huang

Advanced Reliability Robustness and Testing Department, imec, Heverlee, Belgium

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2024 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
WCWen-Chieh Chen
Wen-Chieh Chen
SCShih-Hung Chen
Shih-Hung Chen
MHMan-Ching Huang
Man-Ching Huang
SCShu-Wei Chang
Shu-Wei Chang
GHGeert Hellings
Geert Hellings
GGGuido Groeseneken
Guido Groeseneken
In this work, the challenge of the I/O development roadmap is discussed. Utilizing design and technology co-optimization (DTCO), a cost-effective circuit solution of a 1.8-V general-purpose I/O (GPIO) is proposed in this work. It is not only designed to have comparable performance with standard I/O cells but also better scalability adapting to the sub-3-nm gate-all-around (GAA) nanosheet (NS) technology. The proposed GPIO consists only of core transistors, so that an I/O transistor is not required. To tolerate I/O domain voltage of 1.8 V, the proposed GPIO is designed in the stacked architecture to be 3 $\times$ VDD tolerant. The proposed high-voltage tolerant level shifter with supplementary design achieves better technology scalability regarding performance. The dynamic gate bias (DGB) circuit can prevent gate-dielectric overstress in the output driver under static states. A new voltage-lowering technique has been proposed for receive mode (RX) and achieves better duty cycle and functionality of hysteresis. The functionality is demonstrated in a commercial 16-nm FinFET technology. Furthermore, the device-level reliability of stacked transistors is qualitatively evaluated by the proposed reconfigurable stacked-FET array. The circuit solution to the reliability concern induced by transient overstresses under transmit mode (TX) is proposed. In addition, the circuit-level reliability of the proposed GPIO is examined and shows comparability to the device-level measurement results. Finally, the area penalty and comparison of the conventional I/O buffer and the proposed GPIO has been analyzed, and the technology dependency of device reliability has been discussed.

14 March 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
FLFu-Sung Lin
Fu-Sung Lin
MHMan-Ching Huang
Man-Ching Huang
STSheng-Kwei Tai
Sheng-Kwei Tai
YCYu-Chun Chu
Yu-Chun Chu
SSShih-Hung Shen
Shih-Hung Shen
CHChih-Hsien Huang
Chih-Hsien Huang
Acoustic gas thermometry is a technique that reconstructs the two-dimensional temperature distribution of a gas medium using the acoustic velocities of multiple propagation paths in a region of interest (ROI). In recent years, this technology has gradually replaced traditional temperature measurement devices in combustion industries because acoustic gas thermometers can be installed on side walls and are resistant to dust interference. However, they are too loud for indoor applications such as intelligent buildings. Thus, monitoring indoor temperature distribution with more innovative and easier approaches has become a widely discussed topic. Some researchers have tried to replace the siren sound source with ultrasonic transducers, but such ultrasound gas thermometers can only handle small ROIs or have unknown dynamic hotspot-tracking abilities. To tackle this problem, this research proposes an indoor 2D acoustic gas thermometer that can immediately monitor a large ROI’s 2D gas temperature distribution. By enhancing the transmitting and receiving of ultrasonic signals with a stacked transducer and pre-vibration method, the hardware alone can implement the proposed time-of-flight calculation algorithm. The system drastically reduced the effort of the computation units and was able to acquire the 2D temperature distribution in our experiment in less than 3 seconds. Additionally, a graphical user interface was developed to display and record the information, including the 2D gas temperature distribution of the entire ROI, the temperature profile of the selected cross-section, the temperature values of specific positions, and the velocity of each acoustic path. The relative standard deviations of acoustic velocities measured at room temperature and the heated environment were less than 2%. Finally, experiments involving a moving heat source were conducted to validate the hotspot-tracking capability of the proposed system. The system tracked the heater’s location successfully when it moved 5 cm per 10 seconds and 30 seconds. Thus, the study demonstrated successfully that the proposed 2D gas acoustic thermometer can quickly and accurately measure the temperature distribution and follow the hotspot within a large ROI, such as an intelligent building’s indoor space.