Power Electronics and Electrical Drives Group – GEPAE (Research Group on Power Electronics and Drives), Department Of Electrical Engineering, Federal University of Pernambuco Brazil, Recife, Brazil
Prof. Dr. Fabrício Bradaschia
Power Electronics and Electrical Drives Group – GEPAE (Research Group on Power Electronics and Drives), Department Of Electrical Engineering, Federal University of Pernambuco Brazil, Recife, Brazil
In this paper, a modified Z-source inverter (ZSI) with specific modulation techniques is proposed to reduce leakage currents in three-phase transformerless photovoltaic (PV) systems. The new topology only requires an additional fast-recovery diode when compared with the original structure. On the other hand, the pulsewidth modulation technique is entirely modified in order to reduce the leakage currents through the conduction path. Simulation results for the three-phase transformerless PV system operating in two cases, i.e., connected to a grid and connected to a grounded RL load, are presented. Experimental results of leakage currents in three-phase ZSIs connected to a RL load are obtained to validate the theoretical and simulation models.
5 April 2010 in IEEE Transactions on Power Delivery
A novel scheme for obtaining the fundamental-frequency positive-sequence grid voltage vector based on a generalization of the delayed signal cancellation method is proposed in this paper. The technique is implemented by sampling and storing the instantaneous αβ voltage vector. A mathematical transformation is then proposed through which the current and delayed voltage vectors are combined. It is shown that the proposed transformation has unity gain for the fundamental-frequency positive-sequence voltage vector, while its gain is equal to zero for some chosen components. Cascaded transformations can then be used for eliminating the fundamental-frequency negative-sequence vector, as well as chosen positive- and negative-sequence harmonic vector components and, thus, for accurately obtaining the fundamental-frequency positive-sequence voltage vector. The output of the last transformation block is input to a synchronous reference frame phase-locked loop for detecting frequency and position of the positive-sequence vector. A proposal for making the scheme frequency adaptive is also presented. The good performance of the proposed method is verified with simulations and experiments by using distorted and unbalanced signals, containing fundamental-frequency as well as positive- and negative-sequence harmonic components. The proposed method frequency adaptation capability is also verified.
This paper proposes an estimation method to identify the electrical model parameters of photovoltaic (PV) modules and makes a comparison with other methods already popular in the technical literature. Based on the full single-diode model, the mathematical description of the I-V characteristic of modules is generally represented by a coupled nonlinear equation with five unknown parameters, which is difficult to solve by an analytical approach. The aim of the proposed method is to find the five unknown parameters that guarantee the minimum absolute error between the P-V curves generated by the electrical model and the P-V curves provided by the manufacturers' datasheets for different external conditions such as temperature and irradiance. The first advantage of the proposed method is that the parameters are estimated using the P-V curves instead of I-V curves, since most of the applications that use the electrical model want to accurately estimate the extracted power. The second advantage is that the value ranges of each unknown parameter respect their physical meaning. In order to prove the effectiveness of the proposition, a comparison among methods is carried out using both types of P-V and I-V curves: those obtained by manufacturers' datasheets and those extracted experimentally in the laboratory.
8 September 2017 in IEEE Transactions on Industrial Electronics
In string photovoltaic (PV) systems, the power-voltage (P-V) characteristic under partial shading conditions (PSC) displays multiple peaks requiring global maximum power point (GMPP) tracking (GMPPT) algorithms to identify the PV array GMPP. Several GMPPT algorithms scan wide voltage tracks to detect the GMPP, even larger than a P-V curve full scan. Moreover, many algorithms have been tested only for simple PSC that lead to three well distinct peaks at most. This paper initially presents a trapezoidal area, called the maximum power trapezium (MPT), in the P-V plane that contains all possible GMPPs for any PSC. Using the MPT and information about the minimum voltage difference between adjacent local peaks, a GMPPT algorithm is proposed, which tracks the GMPP of a string PV array under any severe PSC reducing its voltage track and so its tracking time. Simulation and experimental results show the superior performance of the proposed algorithm, in comparison to the state-of-art algorithms, in terms of tracking time, energy loss, and total voltage track during the search for the GMPP.
29 July 2011 in IEEE Transactions on Industrial Electronics
In this paper, two methods for determining the fundamental frequency and harmonic positive- and negative-sequence components of three-phase signals are investigated. Many aspects of the space-vector discrete Fourier transform and generalized delayed signal cancellation (GDSC) such as response time for different possible implementations, frequency adaptation schemes, stability of recursive implementation, and rounding error effects are discussed. A new design procedure for GDSC transformations is presented. New indices for characterizing three-phase unbalanced and distorted signals are proposed. Simulations and experiments are included in order to verify the performances and illustrate the theoretical conclusions.
18 November 2008 in IEEE Transactions on Industrial Electronics
In this paper, a novel scheme for obtaining the fundamental-frequency positive-sequence grid voltage is proposed. The method is based on four simple mathematical transformations; two of them are in the stationary reference frame, which are able to eliminate odd harmonics from the original signals. The other two transformations are implemented in a synchronously rotating reference frame in order to eliminate even harmonics. The output of the last transformation block is the input to a synchronous reference-frame phase-locked loop for detecting the frequency and position of the positive-sequence voltage vector. The proposed algorithm was verified through simulations and experiments by applying distorted and unbalanced signals, containing positive and negative-sequence components. The results are in agreement with those theoretically predicted and indicate that the proposed scheme has a great potential for use in grid-connected converter synchronization algorithms.