Qi Zhang

Qi Zhang

Auto-generated profile, based on publicly available information

Qi Zhang

South China Normal University , Guangzhou

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 April 2025 in The Physics Teacher
Verified
Journal Article
Closed access
QZQi Zhang
Qi Zhang
GDGeman Ding
Geman Ding
GHGuangqing Huang
Guangqing Huang
XWXianqiu Wu
Xianqiu Wu

30 November 2012 in International Journal of Advancements in Computing Technology
Verified
Journal Article
Closed access
RTRui Tang
Rui Tang
LHLi Hou
Li Hou
QZQi Zhang
Qi Zhang

12 October 2016
Verified
Conference Paper
Closed access
PDF file
YLYu Lei
Yu Lei
HCHoupeng Chen
Houpeng Chen
XLXi Li
Xi Li
QWQian Wang
Qian Wang
XFXi Fan
Xi Fan
ZSZhitang Song
Zhitang Song
This paper presents a 2X/1.5X switched-capacitor charge pump for phase change memory (PCM). For a 16-bitparallelism PCM, the set/reset time is more than 100 ns, and the charge pump should output a minimum 60 mA load current. The proposed charge pump can supply 4.1 V voltage and 0-60 mA current for PCM, with an input voltage range of 2.2-3.5 V. It can also automatically change the power conversion ratio between the 2X/1.5X modes according to input voltage. For the improvement of efficiency and load transient response, an auto-adjustable output regulation scheme is employed. In this scheme, two new reference voltages are introduced and compared with output voltage. Average lasting time of the enable signal changes under different load conditions. The Enable signal then controls booster’s power transistors switching to regulate output voltage. In this way, output voltage was controlled within a permissible range. The charge pump has been designed and simulated in a 40nm CMOS process. The results show maximum power efficiency in 30 mA load current is 90.73%, and conversion ratio control increases the efficiency by 23.06% in 3 V.

1 June 2019
Verified
Conference Paper
Closed access
QZQi Zhang
Qi Zhang
YTYu Tang
Yu Tang
SAShaoliang An
Shaoliang An
JLJiangjiang Li
Jiangjiang Li
BCBingjie Chen
Bingjie Chen
Qian ChengQian Cheng
Qian Cheng
In this paper, a novel single-phase seven-level inverter topology is not only proposed but also illustrates the modulation strategy of it. The topology consists of two parts, full-bridge circuit and switched-capacitor circuit which using unipolar pulse-width modulation (PWM) strategy. The strategy allows the full-bridge circuit to operate in seven voltage-level modes, meanwhile, the operation principle and switching actions of the topology are also explicitly analyzed in the text. By controlling the modulation amplitude range, it is possible to implement the 7, 5 and 3 inverter operating modes. The inverters mentioned in this paper can balance the capacitor voltage without auxiliary circuits or complicated control strategies. Finally, a simplified inverter control algorithm is proposed, which realizes proportional resonance (PR). The simulation results show that the proposed inverter can output currents of low THD, which is superior to traditional full-bridge inverter.

1 September 2020
Verified
Conference Paper
Closed access
CHChengshu He
Chengshu He
QCQian Chen
Qian Chen
CWChensheng Wang
Chensheng Wang
QZQi Zhang
Qi Zhang
NQNa Qiu
Na Qiu
Consumption of traditional fossil fuel is becoming a very serious problem, so countries all over the world have begun to pay more and more attention to clean renewable energy generation such as photovoltaic generation and the in-grid technologies. Most new types of generation need to be connected to power grid with inverters. The inverters have no inherent rotational inertia and its primary frequency modulation characteristics are different from that of electric machine, which will bring harmful impact to power grid. Firstly, the primary frequency modulation characteristic of synchronous machine is analyzed, and a new frequency modulation strategy considering dead zone and equivalent offset of rotor speed is proposed, advantages and feasibility of the strategy is verified by simulation example of photovoltaic station. Secondly, characteristics of mechanical inertia of synchronous machine are analyzed, and a feedback control method not relying on external frequency signals but on measured power deviation is proposed and verified by simulation as above. Finally, a combined control strategy considering equivalent mechanical inertia and primary frequency modulation is proposed, which is also verified by simulation case.