18 May 2022 in IEEE Transactions on Medical Imaging
Positron emission tomography is widely used in clinical and preclinical applications. Positronium lifetime carries information about the tissue microenvironment where positrons are emitted, but such information has not been captured because of two technical challenges. One challenge is the low sensitivity in detecting triple coincidence events. This problem has been mitigated by the recent developments of PET scanners with long (1-2 m) axial field of view. The other challenge is the low spatial resolution of the positronium lifetime images formed by existing methods that is determined by the time-of-flight (TOF) resolution (200-500 ps) of existing PET scanners. This paper solves the second challenge by developing a new image reconstruction method to generate high-resolution positronium lifetime images using existing TOF PET. Simulation studies demonstrate that the proposed method can reconstruct positronium lifetime images at much better spatial resolution than the limit set by the TOF resolution of the PET scanner. The proposed method opens up the possibility of performing positronium lifetime imaging using existing TOF PET scanners. The lifetime information can be used to understand the tissue microenvironment in vivo which could facilitate the study of disease mechanism and selection of proper treatments.
23 January 2024 in IEEE Transactions on Medical Imaging
Positron emission tomography (PET) is a widely utilized medical imaging modality that uses positron-emitting radiotracers to visualize biochemical processes in a living body. The spatiotemporal distribution of a radiotracer is estimated by detecting the coincidence photon pairs generated through positron annihilations. In human tissue, about 40% of the positrons form positroniums prior to the annihilation. The lifetime of these positroniums is influenced by the microenvironment in the tissue and could provide valuable information for better understanding of disease progression and treatment response. Currently, there are few methods available for reconstructing high-resolution lifetime images in practical applications. This paper presents an efficient statistical image reconstruction method for positronium lifetime imaging (PLI). We also analyze the random triple-coincidence events in PLI and propose a correction method for random events, which is essential for real applications. Both simulation and experimental studies demonstrate that the proposed method can produce lifetime images with high numerical accuracy, low variance, and resolution comparable to that of the activity images generated by a PET scanner with currently available time-of-flight resolution.
26 June 2025 in IEEE Transactions on Radiation and Plasma Medical Sciences
Positronium imaging was recently proposed to image the properties of positronium atoms in the patient’s body. Positronium properties depend on the size of intramolecular voids and oxygen concentration; therefore, they deliver information different from the anatomic, morphological, and metabolic images. Thus far, the mean ortho-positronium lifetime imaging has been at the center of research interest. The first ex vivo and in vivo positronium lifetime images of humans have been demonstrated with the dedicated J-PET scanner, enabling simultaneous registration of annihilation photons and prompt gamma from β+γ emitters. Annihilation photons are used to reconstruct the annihilation place and time, while prompt gamma is used to reconstruct the time of positronium formation. This review describes recent achievements in the translation of positronium imaging into clinics. The first measurements of positronium lifetime in humans with commercial PET scanners modernized to register triple coincidences are reported. The in vivo observations of differences in ortho-positronium lifetime between tumor and healthy tissues and between different oxygen concentrations are discussed. So far, the positronium lifetime measurements in humans have been completed with clinically available 68Ga, 82Rb, and 124I radionuclides. Status and challenges in developing positronium imaging on a way to a clinically useful procedure are presented and discussed.
26 April 2025 in Communications Physics
Due to the ortho-positronium formed prior to the annihilation, the lifetime of a positron is sensitive to the tissue microenvironment and can potentially provide valuable information for monitoring disease progression and treatment response. However, the lifetime of positrons before annihilation has long been overlooked in current positron emission tomography (PET). Here we develop a positron lifetime image reconstruction method called SIMPLE (Statistical IMage reconstruction of Positron Lifetime via time-wEighting) and demonstrate its performance using a real scan on a time-of-flight PET scanner. The SIMPLE method achieves high-resolution positron lifetime imaging of extended heterogeneous tissue illuminated by a 22Na point source, successfully resolving the boundary between muscle and fat. It delivers spatial resolution comparable to that of conventional PET activity images while maintaining a computational cost equivalent to reconstructing two PET images. This work paves the way for clinical translation of high-resolution positron lifetime imaging.
4 December 2024 in Physics in Medicine & Biology
Objective. Positronium lifetime tomography (PLT) is an emerging modality that aims to reconstruct 3D images of positronium lifetime in humans and animals in vivo. The lifetime of ortho-positronium can be influenced by the microstructure and the concentration of bio-active molecules in tissue, providing valuable information for better understanding disease progression and treatment response. However, efficient high-resolution lifetime image reconstruction methods are currently lacking. Existing methods are either computationally intensive or have poor spatial resolution. This paper presents a fast, high-resolution lifetime image reconstruction method for PLT. Approach. The proposed method, called SIMPLE-Moment (Statistical IMage reconstruction of Positron annihilation LifetimE by Moment weighting), first reconstructs a set of moment images and then estimates the ortho-positronium lifetime image using the method of moments. The implementation of SIMPLE-Moment requires minimal modification to the conventional ordered subset expectation maximization algorithm. Main results. With reasonable assumptions, the proposed method can reconstruct an ortho-positronium lifetime image with a computational cost equivalent to three standard positron emission tomography (PET) image reconstructions. A Monte Carlo simulation study based on an existing time-of-flight PET scanner demonstrates that the ortho-positronium lifetime image reconstructed by SIMPLE-Moment is accurate and comparable to results obtained using the more computationally intensive Statistical Positronium Lifetime Image reconstruction via time-Thresholding (SPLIT) method. Significance. The proposed SIMPLE-Moment method provides an efficient approach to high-resolution reconstruction of ortho-positronium lifetime images. By reducing computational costs while enhancing spatial resolution, this method has the potential to make PLT more accessible and practical for clinical and research applications.
23 October 2024 in Physics in Medicine & Biology
Objective. This study presents a universal phantom for positron emission tomography (PET) that allows arbitrary static and dynamic activity distributions of various complexities to be generated using a single PET acquisition. Approach. We collected a high-statistics dataset (with a total of 22.4 × 109 prompt coincidences and an event density of 2.75 × 106 events mm−3) by raster-scanning a single plane with a 22Na point source mounted on a robotic arm in the field-of-view of the uEXPLORER PET/CT scanner. The source position was determined from the reconstructed dynamic frames. Uniquely, true coincidences were separated from scattered and random events based on the distance between their line-of-response and the known source location. Finally, we randomly sampled the dataset to generate the desired activity distributions modeling several different phantoms. Main results. Overall, the target and the reconstructed phantom images had good agreement. The analysis of a simple geometric distribution showed high quantitative accuracy of the phantom, with mean error of <–3.0% relative to the ground truth for activity concentrations ranging from 5.3 to 47.7 kBq ml−1. The model of a high-resolution 18F-fluorodeoxyglucose distribution in the brain illustrates the usefulness of the technique in simulating realistic static neuroimaging studies. A dynamic 18F-florbetaben study was modeled based on the time-activity curves of a human study and a segmented brain phantom with no coincidences repeating between frames. For all time points, the mean voxel-wise errors ranged from –4.4% to –0.7% in grey matter and from −3.9% to +2.8% in white matter. Significance. The proposed phantom technique is highly flexible and allows modeling of static and dynamic brain PET studies with high quantitative accuracy. It overcomes several key limitations of the existing phantoms and has many promising applications for the purposes of image reconstruction, data correction methods, and system performance evaluation, particularly for new high-performance dedicated brain PET scanners.