Zhou Dong

Zhou Dong

Auto-generated profile, based on publicly available information

Zhou Dong

Department of Electrical Engineering and Computer Science, The University of Tennessee, Knoxville, Knoxville, TN, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ZDZhou Dong
Zhou Dong
RRRen Ren
Ren Ren
FWFei Wang
Fei Wang
The high-power solid-state power controller (SSPC) will be a critical component for the future electrified aircraft propulsion system. This article presents the development of a 1 kV 500 A bidirectional dc SSPC using SiC power modules and transient voltage suppression (TVS) diodes. The design procedure and implementation of the SSPC are presented in detail and the system level influence is discussed. Due to the limited power of a single switch, parallel and/or series connections of switches are necessary for high-power SSPCs, and the corresponding challenges are investigated with possible solutions. In addition, the high peak-to-average clamping voltage ratio caused by Ldi/dt of the turn-off current commutation and foldback characteristics of high-power TVS diodes is addressed. Finally, the testing setups for the high-power SSPC are presented, and all key functions are tested for the SSPC. The power rating and the specific power of the developed SSPC are superior to state-of-the-art counterparts to show the advantage of the developed one.

24 March 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZDZhou Dong
Zhou Dong
RRRen Ren
Ren Ren
WZWen Zhang
Wen Zhang
FWFei Fred Wang
Fei Fred Wang
LTLeon M. Tolbert
Leon M. Tolbert
Paralleled dies in a power module could have instability issues during high current switching transients. The instability is caused by the differential-mode oscillation among paralleled MOSFETs. Conventional analyses of paralleled MOSFETs’ stability are normally limited to a single operating point, which ignores the influences of the switching trajectory and nonlinear device parameters on stability. This article reveals that the switching trajectory can significantly influence parallel stability. The analysis is improved by solving eigenvalues of state-space modeling system matrices of all operating points that the switching trajectory goes through considering nonlinear device parameters. Higher voltage and current stresses result in greater real parts of complex eigenvalues, which explains why the paralleled MOSFETs are more unstable with higher voltage and current stresses. To improve stability in solid-state circuit breaker applications, we propose a method to manipulate the switching trajectory to avoid the unstable region where the conventional hard switching trajectory normally goes through. Experimental results show that the turn- off current capability can be increased from ∼five times of rated current with the gate oscillation using the conventional turn- off trajectory to ∼ten times of rated current without the gate oscillation using the optimal turn- off trajectory.

9 July 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SDShimul K. Dam
Shimul K. Dam
CYChing-Hsiang Yang
Ching-Hsiang Yang
ZDZhou Dong
Zhou Dong
DQDehao Qin
Dehao Qin
RCRuirui Chen
Ruirui Chen
ZZZheyu Zhang
Zheyu Zhang
Solid-state circuit breaker (SSCB) with high efficiency and high gravimetric power density is required for electrified aircraft propulsion (EAP). A cryogenically cooled gallium nitride (GaN) device-based SSCB module is developed for the EAP system to achieve a higher power density than existing SSCBs. The SSCB module is suitable for medium voltage direct current (MVdc) applications and is designed with low-weight modular cold plates. Each module is rated for 750 V, 100 A, and can interrupt a fault current of 1 kA at cryogenic temperature. The SSCB module structure design, thermal interface design, modular cold plate design, and insulation design are discussed. The developed SSCB module prototype achieves a power density of 329 kW/kg and an efficiency of 99.93%. Experimental results of interrupting a fault of 1 kA and insulation test of the SSCB module are provided to validate its operation.

17 August 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZDZhou Dong
Zhou Dong
CYChing-Hsiang Yang
Ching-Hsiang Yang
SDShimul Kumar Dam
Shimul Kumar Dam
DQDehao Qin
Dehao Qin
RCRuirui Chen
Ruirui Chen
ZZZheyu Zhang
Zheyu Zhang
The current limiting function enables the solid-state circuit breaker (SSCB) to have proper protection coordination. It allows sustained overcurrent for a certain period while preventing the fast fault current increase in dc systems. For the conventional method of using switches alone to limit the current, the high loss results in a short withstand time and low current limiting capability of the SSCBs. In this letter, a control strategy is proposed to utilize the energy absorption component to handle the major part of the energy during the current limiting stage to increase the current limiting capability for series-connected SSCB switching cells. The proposed method is experimentally verified to have more than 3X current limiting withstand time compared to the conventional control strategy in a case study.

22 September 2022 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
ASAnil Kumar Reddy Siddavatam
Anil Kumar Reddy Siddavatam
Kaushik RajashekaraKaushik Rajashekara
Kaushik Rajashekara
RRRavi Prakash Reddy
Ravi Prakash Reddy
Hao HuangHao Huang
Hao Huang
HKHarish S. Krishnamoorthy
Harish S. Krishnamoorthy
FWFred Wang
Fred Wang
This paper introduces two electrical architectures for electric/ hybrid-electric aircraft propulsion systems to address the issues of the radial baseline architecture, where a single bus feeds the four propulsion motors. A fault on this bus results in complete isolation of the bus to which propulsion motors are connected. By using the proposed architectures, the fault can be isolated without having to disconnect all the propulsion motors. This would increase the reliability, redundancy, and robustness of the electrical system, and/or avoid oversizing the components present in the architecture. In this paper, the protection strategy and action of circuit breakers are discussed for different fault conditions. The enhanced fault-tolerant operation of the proposed architectures over the existing radial baseline architecture for the electrified aircraft propulsion (EAP) system is validated for both open circuit and short circuit faults at different locations in the system, using controller hardware in the loop results obtained using typhoon HIL testbed. Furthermore, the feasibility analysis of interconnecting the individual propulsion channels to reduce the over-sizing of components is also discussed.

28 June 2024 in IEEE Open Journal of the Industrial Electronics Society
Verified
Journal Article
Open access
SZShuyan Zhao
Shuyan Zhao
CXChunmeng Xu
Chunmeng Xu
LRLakshmi Ravi
Lakshmi Ravi
ZDZhou Dong
Zhou Dong
PCPietro Cairoli
Pietro Cairoli
Voltage clamping circuits are critical components in most direct-current circuit breakers (DCCBs) to achieve ultrafast DC fault interruptions and an extended lifetime. A key performance index of voltage clamping circuits is the overvoltage ratio, which calculates the peak switching overvoltage over the nominal voltage during fault interruption processes. A lower overvoltage ratio is beneficial to minimize the DCCB insulation voltage and reduce the total breaker cost, meanwhile alleviating the overvoltage interference to the DC bus and thus enhancing the stability of the DC power system. This paper evaluates the overvoltage ratio of various clamping circuits reported in DCCB literature. The basic working principles, switching overvoltage magnitude, advantages and limitations of different voltage clamping circuits are evaluated by circuit simulations. A capacitor-metal oxide varistor (C-MOV) circuit is selected for experimental validation considering its specifically low overvoltage ratio. The C-MOV prototype is verified with high power tests at 1 kV DC bus. The measured overvoltage ratio of the C-MOV prototype matches parametric analyses. The effects of stray inductance and fault rise rate on the overvoltage ratio are also experimentally validated. Finally, the C-MOV circuit is compared with other voltage clamping circuits in the literature to demonstrate its benefits and limitations in DCCB applications.