13 December 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Increasing inverter-based sources reduces the system’s inertia resulting in possible frequency stability issues. Understanding low-inertia systems and their stability properties is of crucial importance. This article introduces fundamental ways to integrate high levels of renewable energy (RE) and distributed energy resources (DERs) in the power system while creating a more flexible power system. Using RE and DER in the distribution system has many advantages such as reducing the physical and electrical distance between generation and loads, bringing sources closer to loads contributes to the enhancement of the voltage profile, reduction in distribution and transmission bottlenecks, improved reliability, lower losses, and enhances the potential use of waste heat. A basic issue for high penetration of DER is the technical complexity of controlling hundreds of thousands to millions of inverters. This is addressed through autonomous techniques using local measurements eliminating the need for fast control systems. The key issues addressed in this article include using inverter damping to stabilize frequency in systems with low or no inertia, autonomous operation, methods for relieving inverter overload, energy reserves, and their implementation in photovoltaics (PV) systems. This article provides important insight into the interactions between inverter bases sources and the high-power system. The distinction between grid-forming (GFM) inverter and grid-following (GFL) inverter is profound. GFM inverters provide damping to frequency swings in a mixed system, while GFL inverter can aggravate frequency problems with increased penetration. Rather than acting as a source of inertia, the GFM inverter acts as a source of damping to the system. On the other hand, the application of inverters in the power system has two major issues. One is the complexity of controlling hundreds of thousands to millions of inverters. This is addressed through autonomous techniques using local measurements. The other is the potential of high overcurrent in GFM inverters and techniques for explicitly protecting against overloading. To exploit the innate damping of GFM inverters, energy reserves are critical.
19 September 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Historically, two similar grid-forming droop controls are widely reported in literature—the single-and multi-loop droop controls. Although being very similar, the authors find that the dynamic performance and stability characteristics of each control method are very different in a microgrid. Compared with single-loop droop control, the multi-loop droop control is prone to be less damped and loses stability more easily under some circumstances. This paper provides a novel insight into the different dynamic responses of the two basic controls. It points out that the two similar controls adjust the angular frequency and voltage magnitude at different locations within the inverter, resulting in different coupling reactances that impact the dynamic response and stability of microgrids differently. The use of single-loop droop control results in a larger coupling reactance, which helps to improve dynamic response and stability. This novel insight is verified through full-order small signal analysis, offline electromagnetic transient simulation, and real-time hardware-in-the-loop simulation experiments. Results show that the microgrid has a larger small signal stability boundary when using single-loop droop control, and this difference increases as the value of an inverter’s inner filter inductance increases.
21 August 2020 in IEEE Transactions on Power Delivery
Historically, distribution system planning studies mainly focused on steady state and quasi-steady state analysis, with limited attention paid to dynamic analysis. This paper develops three-phase, electromechanical models for both grid-forming and grid-following inverters, and integrates them into an open source, three-phase distribution network solver, thereby enabling dynamic simulation of large-scale, three-phase unbalanced distribution systems with high penetration of inverter-based DERs. The proposed inverter models are validated against electromagnetic simulation and field test data from the CERTS/AEP microgrid testbed, and simulated in an islanded 5252 node distribution system in the GridLAB-D simulation environment. Simulation verifies the effectiveness of the proposed inverter models for large-scale distribution system analysis. Study results show that compared to traditional grid-following inverters, the high penetration of grid-forming inverters can improve the voltage and frequency stability of islanded distribution systems.
12 September 2022 in IEEE Transactions on Energy Conversion
A key challenge associated with a grid-forming (GFM) inverter based resource (IBR) is its behavior during severe grid disturbances: since a GFM inverter regulates voltage in the fast timescale instead of current or power, it may experience a transient overload of current, power and/or energy during a severe grid disturbance. While many promising control strategies for overload ride-through have been proposed over the past two decades, transient stability of the system during and after the transition to an overload ride-through control mode remains difficult to guarantee. In this work, a novel overload ride-through control strategy is proposed for a system of grid-forming inverters that takes both self-protection and system-wide transient stability into account. A proposed system-level supervisory control uses slow communication to pre-emptively assign a set of local ride-through control parameters to individual GFM IBR, including a current-limiting virtual reactance, that guarantees that synchronism is still preserved for any set of anticipated grid disturbances. At the core of the supervisory control lies a Lyapunov-function-based routine capable of establishing a strong, albeit conservative, transient stability guarantee for the system. The proposed overload ride-through control strategy is validated via numerical integration of a reduced-order model, as well as through detailed electromagnetic transient (EMT) simulation.
3 August 2023 in IEEE Transactions on Industry Applications
This paper presents a small-signal stability analysis tool for large-scale power systems with high penetration of inverter-based resources (IBRs). Firstly, a network transfer function matrix (NTFM), which represents the information of the system topology, transmission lines, loads, IBRs locations, etc., is derived to model the entire power system network. Secondly, small-signal perturbation method is applied to obtain the sequence impedance/admittance models of the block-box IBRs considering the frequency cross-coupling effects. With the obtained NTFM as well as IBR models, a multi-input, multi-output (MIMO) feedback system is constructed, and the generalized Nyquist criterion (GNC)-based stability method is employed to analyze the stability of the entire power system. Furthermore, based on the developed stability analysis method, sensitivity analysis is conducted on an unstable case to identify which parameter has a high impact on the system stability. Different test cases based on a modified IEEE 14-bus system as well as a reduced 240-bus WECC system are studied to verify the proposed stability analysis tool.
25 July 2025 in IEEE Transactions on Smart Grid
Co-simulation offers a time-efficient method for ac-curately analyzing the behavior of distribution systems dominated by inverter-based resources (IBRs). However, most co-simulation studies in the literature overlook distribution grids. Additionally, these studies do not discuss practical IBR models nor how to ini-tialize the interface model variables of co-simulation platforms. To obtain co-simulation results that are reasonably accurate for dis-tribution system-based planning and operation, it is pertinent to develop co-simulation platforms well-suited for studying the accu-rate behavior of IBRs coupled to unbalanced distribution grids. This paper introduces an initialization algorithm for initializing the interface model variables of co-simulation platforms. The ini-tialization algorithm is anchored on leveraging the fast execution speed of the per-phase phasor simulation to quickly pre-calculate initial values of interface model variables prior to starting co-sim-ulation. This paper further proposes the inclusion of rate limiters in the co-simulation platforms interface models to prevent the in-capability of the per-phase phasor simulator to clear faults at zero-crossing of currents from falsely impacting the control system of practical IBR models. The proposed methods are validated by benchmarking the results from a per-phase phasor/electromag-netic transient (EMT) co-simulation of an IBRs-dominated IEEE 34-Node test feeder against the results from a full EMT simulation.