Tobias Milde

Tobias Milde

Auto-generated profile, based on publicly available information

Tobias Milde

Sacher Lasertechnik GmbH

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2018 in Applied Optics
Verified
Journal Article
Closed access
PDF file
TMTobias Milde
Tobias Milde
MHMorten Hoppe
Morten Hoppe
HTHerve Tatenguem
Herve Tatenguem
MMMario Mordmüller
Mario Mordmüller
JOJames O’gOrman
James O’gOrman
JSJoachim Sacher
Joachim Sacher
The measurement of trace gases has increasingly become a key technique in healthcare and other medical applications. Quartz-enhanced photoacoustic spectroscopy (QEPAS) is a suitable method that can provide the required characteristics in such applications for a comparatively low cost and small size. The quantitative detection and a low detection limit are also required by applications. In this paper, we present new results on sensing biomedically relevant gases using the on-beam QEPAS technique with some newly developed tunable high-power single-mode laser diodes based on GaSb material. The data processing and detection limit determination are done by a field programmable gate array device, as well as an automatic measurement of the resonance frequency.

8 September 2017 in Applied Optics
Verified
Journal Article
Closed access
PDF file
TMTobias Milde
Tobias Milde
CAChristian Assmann
Christian Assmann
AJAlvaro Jimenez
Alvaro Jimenez
MHMartin Honsberg
Martin Honsberg
JOJames O’gOrman
James O’gOrman
JSJoachim Sacher
Joachim Sacher
The wavelength, λ, range of 1.8  μm≤λ≤3.5  μm contains strong spectral absorption lines of many gases used in health, industry, safety, and medicine and whose sensitive and quantitative detection is desirable. However, the performance of InP diode lasers markedly deteriorates beyond λ∼2  μm. In this paper we present new results on developing tunable high power single mode laser diodes based on the GaSb material system with emission in the wavelength range of 1.8  μm≤λ≤2.2  μm.

26 April 2021 in Journal of the Optical Society of America B
Verified
Journal Article
Closed access
PDF file
MHMorten Hoppe
Morten Hoppe
CAChristian Aßmann
Christian Aßmann
SSSebastian Schmidtmann
Sebastian Schmidtmann
TMTobias Milde
Tobias Milde
MHMartin Honsberg
Martin Honsberg
JSJoachim Sacher
Joachim Sacher
The commercially available semiconductor lasers for the mid-infrared (MIR) region often do not reach the desired performance and represent a limitation for gas sensor technology. Here we present our digital distributed feedback filter (D-DFB) laser diodes based on GaSb gain material, which have been optimized in terms of facet reflectivity, chip length, and output power. These diodes now cover the wavelength range from 1900 nm up to 4500 nm and show excellent quality regarding their spectral characteristics. Results for the performance of the D-DFB laser design and its suitability for the detection of trace gases are shown in this publication.

9 April 2021 in Applied Optics
Verified
Journal Article
Closed access
PDF file
TMTobias Milde
Tobias Milde
MHMorten Hoppe
Morten Hoppe
HTHerve Tatenguem
Herve Tatenguem
HRHanna Rohling
Hanna Rohling
SSSebastian Schmidtmann
Sebastian Schmidtmann
JSJoachim Sacher
Joachim Sacher
Molecular gases are highly relevant in healthcare, production control, safety, and environmental monitoring. They often appear in small concentrations. The measurement of trace gases has increasingly become a key technique in those domains. Quartz-enhanced photoacoustic spectroscopy (QEPAS) is a suitable method that can provide the required low detection limits in such applications at comparatively low cost and small size. For mobile implementation, the size of an entire sensor unit matters. In this paper, we present a QEPAS sensor that fits into a standard butterfly package, its characterization, and its application on C H 4 and C O 2 .

26 March 2019 in Applied Optics
Verified
Journal Article
Closed access
PDF file
TMTobias Milde
Tobias Milde
MHMorten Hoppe
Morten Hoppe
HTHerve Tatenguem
Herve Tatenguem
CAChristian Assmann
Christian Assmann
WSWolfgang Schade
Wolfgang Schade
JSJoachim Sacher
Joachim Sacher
The MIR wavelength regime promises better gas detection possibilities than the NIR or the visible region because of the higher absorbencies simulated by HITRAN. In the MIR region are many important absorption lines of significant gases, which are relevant in healthcare, production supervision, and safety and environmental monitoring. One of those gases is methane. CH4 shows significant variations in absorbance with a maximum at 3.3 μm, which results in low detection limits in the range of low ppm. Interband-cascade- and quantum-cascade-based lasers emit at higher wavelengths, where the absorbencies of methane are higher. The comparison is done by analyzing the performance of two spectroscopy applications: tunable diode laser absorption spectroscopy and quartz-enhanced photoacoustic spectroscopy.

18 April 2019 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Closed access
MHMorten Hoppe
Morten Hoppe
AJAlvaro Jimenez
Alvaro Jimenez
HRHanna Rohling
Hanna Rohling
SSSebastian Schmidtmann
Sebastian Schmidtmann
JGJan Grahmann
Jan Grahmann
JSJoachim R. Sacher
Joachim R. Sacher
Widely tunable external cavity diode lasers (ECDLs) with a narrow linewidth have become a powerful tool for a variety of applications. The difficulty of the present generation of ECDLs is that they are designed as laboratory instruments and are limited due to their size, high costs, and sensitivity to external influences. In this paper, we present our new ECDL design based on a microelectromechanical system (MEMS) device. This design overcomes the previous drawbacks and offers an outstanding improvement of the most important properties. Moreover, it can be adapted to any wavelength of interest and by using MEMS technology, costs can be reduced.