18 August 2021 in IEEE Transactions on Power Electronics
Wireless power transfer (WPT) is emerging as the preeminent way to charge electric vehicles, but there appears to be no fair way to measure the power transfer. In this article, Faraday coil transfer-power measurement (FC-TPM) is presented. FC-TPM employs non-contact, open-circuited sense coils to measure the electromagnetic field from WPT and calculates the real power propagating through the air gap between the transmitter and receiver coils. What is measured is the real electromagnetic power, representing the pure dispensation of energy that unambiguously demarcates the losses on either side. FC-TPM was demonstrated to be 0.1% accurate in hardware over an Rx coil misalignment of up to 10 cm using a 1-kW WPT system. Fair metering incentivizes businesses and individuals to make choices that conserve energy and advance technology by providing more information and by properly assigning the financial loss. This article is accompanied by a video highlighting the essential contributions of this article.
27 July 2021 in IEEE Transactions on Power Electronics
Foreign objects near wireless power transfer (WPT) systems are fire hazards that must be detected. In this article, a new accurate method is presented for foreign object detection based on an electromagnetic model for WPT. Foreign objects are detected by quantifying the deviation from a normal model. This deviation is caused by the foreign object's additional electromagnetic coupling. Advantages of this new method include invariance to receiver coil misalignment, and power level, allowing low-power detection prior to startup. Electromagnetic model-based foreign object detection was demonstrated in hardware to detect a 2 cm diameter U.S. nickel coin, a small disposable lighter, and a saline proxy for a living animal in a kilowatt-level wireless power transfer system, using a prestartup power of only 7 W. Furthermore, foreign objects can be detected regardless of an Rx coil misalignment of up to 10 cm. This article is accompanied by an instructional video.
26 May 2021 in IEEE Transactions on Industry Applications
This article introduces a 4 kV/120 A solid-state dc circuit breaker (DCCB) based on discrete SiC mosfets. The DCCB is designed in a five-layer tower structure. Each layer consists of a circular main conduction branch and an attached gate driver. There are two primary benefits of the proposed DCCB. First, it reduces conduction loss with multiple devices in parallel. Second, it achieves an ultrafast response speed with SiC mosfets. Moreover, the gate drivers of the DCCB are powered by a domino inductive power transfer (IPT) system. It achieves the load-independent constant-voltage output characteristics, which means the outputs are immune to load variations. An IPT system prototype is implemented to test the power transfer performance. At 500-kHz frequency, the total output power reaches 15.73 W, which is sufficient to power on five gate drivers, with a peak transfer efficiency of 75.4%. The IPT system is tested to power a 4 kV/120 A DCCB prototype. It validates that the DCCB is effective to turn off 120 A current within 3.5 μs.
26 August 2022 in IEEE Transactions on Power Electronics
This article proposes a new thyristor-based dc solid-state circuit breaker (SSCB) named Y-type. Main contributions focus on a new complementary commutation circuit including a capacitor–capacitor pair, which features three remarkable advantages. First, a fast commutation is achieved using a countercurrent pulse injection by the capacitor–capacitor pair structure. Second, metal-oxide varistors (MOVs) are disconnected from the power line when SSCB is off , which solves the reliability issue due to the MOV degradation and enhances the voltage utilization rate of the main switch. Third, benefiting from the capacitor–capacitor pair structure, reliable reclosing and rebreaking are obtained for practical applications. Experiments are conducted on a 400 V/120 A prototype to validate the proposed Y-SSCB. The peak voltage on the main and auxiliary thyristors reaches 773 and 400 V, respectively. Also, the peak voltage on the auxiliary capacitors pair reaches 740 and 400 V. The Y-SSCB achieves a fast reaction time of 80 μs in interrupting 120 A short-circuit fault current.
2 February 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Power conversion for wireless power transfer (WPT) at 100MHz is important for miniaturization and integration, which is critical for charging wearable consumer electronics, and devices for the Internet of Things (IoT). Design and implementation at this frequency are challenging in the selection of components and circuit configurations for operation over a wide load range. The optimization of the tuned compensation networks together with a step-by-step guide for a systematic and rigorous optimal design is derived in this paper from fundamental circuit models for symmetric current-mode class D (CMCD) WPT systems. Symmetric CMCD WPT systems can have inherently constant output current for a wide load range with small current ripple for the optimal design, which is useful in direct battery charging applications. Both uncontrolled and synchronous rectifiers are analyzed, demonstrated, and compared in hardware with the optimal designs. A 100MHz prototype with an output peak power of 6.9W has a power circuit dc–dc efficiency of 81.9% despite only natural convection cooling of miniaturized GaN devices. The prototype maintains nearly constant power circuit efficiency above 80.5% with a peak of 83.2% over a wide power range that spans from 1.7W to 6.9W.
13 December 2021 in IEEE Transactions on Power Electronics
This letter presents a new auxiliary circuit to achieve transient current commutation (TCC) in dc solid-state circuit breakers (SSCBs). The auxiliary circuit consists of two parts: active injection circuits (AIC) and capacitive couplers. There are two contributions. First, coupling capacitors between AIC and the main branch are introduced to prevent short circuit failures in the auxiliary branch. Second, a boost converter-based resonant circuit is presented for AIC to achieve TCC in the main branch through couplers. The presented AIC tunes the duration time and amplitude of injected countercurrent pulses during dc current interruption. The working principle and design procedure of the auxiliary circuit are presented. The proposed topology is verified by experiments of a 2 kV/100 A dc SSCB prototype under load current interruption. The experimental results show that the injected pulse current through couplers reaches 110 A, and it decays to zero within 12.5 μs. The total reaction time interval including the communication delay and the AIC current rising delay is 108 μs. Meanwhile, the peak voltages across the main branch and the coupler reach 2099 V and 2193 V, respectively.