16 October 2024 in IEEE Transactions on Instrumentation and Measurement
This article presents a novel approach to measuring gas-liquid two-phase flow using a throat-extended Venturi meter (TEVM) based on differential pressure (DP) ratios and fluctuations. The over-reading (OR) and mass quality are the dominant parameters for accurate mass flowrate measurement by a TEVM. First, a liquid OR model is established based on multiple DP ratios, gas-to-liquid density ratio, and liquid densitometric Froude number. This model is solved by integrating a deep neural network (DNN) with an iterative optimization technique. Subsequently, a mass quality model is developed based on multi-DP fluctuations and other related parameters, which can also be solved using a DNN. Finally, the liquid and gas mass flowrates are obtained sequentially from the preceding results. The proposed method addresses the issue of significant errors in the direct solution of the conventional dual-parameter measurements. It utilizes both the static and dynamic features of multi-DP to achieve the simultaneous measurement of gas and liquid mass flowrate using a single TEVM. The experiment was conducted within the a gas flowrate range of 1.3×10 -4 ~5.1×10 -3 kg/s, and a liquid flowrate range of 1.12~3.95 kg/s. The results demonstrate that the relative error for liquid and gas mass flowrate is within ±3% and ±10%, respectively. This indicates that the proposed method is a cost-effective and viable solution for gas-liquid two-phase flow metering using a TEVM, and it can be further adapted to other experimental conditions.
9 January 2024 in IEEE Transactions on Instrumentation and Measurement
This article presents an image reconstruction method for open electrical impedance tomography (OEIT) combined with inversion mapping and contour representation to address the profile and medium distribution measurement requirements of adhesion cavitation. Electrodes are arranged on the surface of an axisymmetric blunt body to form the Open-EIT sensor. To guarantee the accuracy of forward modeling in image reconstruction, the infinite domain outside the sensor is transformed into a disk by an equivalent dedicated inversion mapping. Then, the cavity contour is obtained using a customized B-spline-based sparse reconstruction method. Finally, the medium distribution to be reconstructed is confined within the contour to improve the imaging speed and resolution, which is then mapped back to the original infinity domain. Theoretical analysis and simulation demonstrate that the forward model maintains physical consistency after the inversion mapping, and the detection sensitivity is nearly ten times higher than that before the mapping. Simulations and experiments were conducted to verify the effectiveness of the proposed method, where the contour and its inside distribution can be better reconstructed in each specified case compared to other typical methods. The aforementioned method establishes a viable and effective approach for monitoring the cavitation occurrence on the surface of underwater vehicles.
13 February 2026 in IEEE Transactions on Instrumentation and Measurement
Subtle disturbances of supercavity profile can destabilize high-speed underwater vehicles, potentially causing severe accidents. Existing methods struggle to online monitor the supercavity profile on the outer surface of the axisymmetric gyratory body of an underwater vehicle. Electrical capacitance tomography (ECT), with its soft-field characteristics, offers a promising solution, but traditional approaches face limitations on reconstructing supercavity profile with high sensitivity and resolution due to the large permittivity contrast between water and air. This study proposes an Outward Electrical Capacitance Ratio Tomography (OECRT) framework for the monitoring of supercavity profile, where it is theoretically proved that the specified inter-electrode capacitance ratio is only sensitive to air-water interface irrespective of the dielectric contrast. Unlike traditional closed-domain ECT, OECRT establishes a direct bijective function between the boundary inter-electrode capacitance ratios and the open-domain supercavity profile. Results of water-entry experiments demonstrate that OECRT outperforms the conventional methods in both the sensitivity to phase interface changes and spatial and temporal resolutions. The proposed OECRT method is a promising alternative to the traditional closed-domain ECT methods, especially in the cases where there exists large dielectric contrast between the target and background media or open-domain imaging is required.
3 June 2025 in IEEE Sensors Journal
This article presents a novel method for measuring the mass flow rate of gas-liquid two-phase flow based on the multi-sensor data fusion and soft computing model. A multi-sensor system comprising a throat-extended Venturi tube and a dual-modality electrical sensor has been developed for gas-liquid two-phase flow measurement. Soft computing models are employed to address the intricate non-linear mapping between the measurement data and flow parameters. Initially, flow regimes are identified based on the time-domain features of the multi-sensor data using a support vector machine. Subsequently, mass quality is derived from the multi-differential pressure fluctuations and the eigenvalue sequence of the normalized electrical matrices, employing a hybrid neural network comprising a convolution neural network and a deep neural network. Ultimately, gas/liquid over-reading is predicted via Extreme Gradient Boosting using multi-differential pressure ratios. The gas and liquid mass flow rates are subsequently derived from the preceding results. The proposed method addresses the issue that the parameters measurement of gas-liquid two-phase flow is significantly influenced by the flow regimes, and achieves accurate flow rate measurement under the diverse flow regimes. Experimental validation confirms the method’s effectiveness and superior performance compared to conventional approaches.
3 March 2025 in IEEE Transactions on Instrumentation and Measurement
In this paper, an analog lock-in amplifier (ALIA) based on synchronous in-phase and quadrature (I/Q) demodulation is proposed for wide range capacitance measurement of high accuracy. In order to improve the signal-to-noise ratio (SNR), an extra compensation channel was employed to quickly pre-determine the capacitance to be measured and optimize the measurement configurations. A transimpedance amplifiers is designed to eliminate the adverse impacts of parasitic parameters for optimal SNR, which is accomplished by applying an adaptive strategy to control the excitation frequency and compensation capacitance. Additionally, a capacitance measurement model with improved accuracy is established by considering the effect of non-ideal characteristics of devices. A prototype is fabricated and tested to verify the effectiveness of the proposed ALIA. It is shown that the ALIA has excellent comprehensive performances, which can achieve capacitance measurement with an average error of 0.52% in a wide range of 10 fF-10 nF. The measurement error is reduced by 9.74% in the full-scale range by considering the non-ideal characteristics of devices, which is reduced by 25.24% in measuring small-valued capacitances (<1 pF), compared to a commercial lock-in amplifier. The ALIA has a strong robustness against additive noise with a SNR of -42 dB. Additionally, a comprehensive uncertainty budget is presented and the uncertainty components of the system are identified and summarized. A low capacitance measurement uncertainty budget ranges from -57.1 dB to -50.8 dB in the full-scale range.
14 December 2024 in Measurement