Rajesh Ghosh

Rajesh Ghosh

Auto-generated profile, based on publicly available information

Rajesh Ghosh

Bioengineering Department, University of California, Los Angeles, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
GHGyeo-Re Han
Gyeo-Re Han
AGArtem Goncharov
Artem Goncharov
MEMerve Eryilmaz
Merve Eryilmaz
Shun YeShun Ye
Shun Ye
Barath PalanisamyBarath Palanisamy
Barath Palanisamy
Aydogan OzcanAydogan Ozcan
Aydogan Ozcan
The landscape of diagnostic testing is undergoing a significant transformation, driven by the integration of artificial intelligence (AI) and machine learning (ML) into decentralized, rapid, and accessible sensor platforms for point-of-care testing (POCT). The COVID-19 pandemic has accelerated the shift from centralized laboratory testing but also catalyzed the development of next-generation POCT platforms that leverage ML to enhance the accuracy, sensitivity, and overall efficiency of point-of-care sensors. This Perspective explores how ML is being embedded into various POCT modalities, including lateral flow assays, vertical flow assays, nucleic acid amplification tests, and imaging-based sensors, illustrating their impact through different applications. We also discuss several challenges, such as regulatory hurdles, reliability, and privacy concerns, that must be overcome for the widespread adoption of ML-enhanced POCT in clinical settings and provide a comprehensive overview of the current state of ML-driven POCT technologies, highlighting their potential impact in the future of healthcare.

27 May 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RGRajesh Ghosh
Rajesh Ghosh
SGSaranya Gopalakrishnan
Saranya Gopalakrishnan
RSRangasamy Savitha
Rangasamy Savitha
TRThiruvengadam Renganathan
Thiruvengadam Renganathan
SPSubramanium Pushpavanam
Subramanium Pushpavanam
Microfluidic paper-based analytical devices (µPADs) have provided a breakthrough in portable and low-cost point-of-care diagnostics. Despite their significant scope, the complexity of fabrication and reliance on expensive and sophisticated tools, have limited their outreach and possibility of commercialization. Herein, we report for the first time, a facile method to fabricate µPADs using a commonly available laser printer which drastically reduces the cost and complexity of fabrication. Toner ink is used to pattern the µPADs by printing, without modifying any factory configuration of the laser printer. Hydrophobic barriers are created by heating the patterned paper which melts the toner ink, facilitating its wicking into the cross-section of the substrate. Further, we demonstrate the utilization of the fabricated device by performing two assays. The proposed technique provides a versatile platform for rapid prototyping of µPADs with significant prospect in both developed and resource constrained region.

1 April 2019 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
RGRajesh Ghosh
Rajesh Ghosh
ASAvinash Sahu
Avinash Sahu
SPS Pushpavanam
S Pushpavanam

4 October 2024 in ACS Nano
Verified
Journal Article
Open access
GHGyeo-Re Han
Gyeo-Re Han
AGArtem Goncharov
Artem Goncharov
MEMerve Eryilmaz
Merve Eryilmaz
HJHyou-Arm Joung
Hyou-Arm Joung
RGRajesh Ghosh
Rajesh Ghosh
Aydogan OzcanAydogan Ozcan
Aydogan Ozcan
Successful integration of point-of-care testing (POCT) into clinical settings requires improved assay sensitivity and precision to match laboratory standards. Here, we show how innovations in amplified biosensing, imaging, and data processing, coupled with deep learning, can help improve POCT. To demonstrate the performance of our approach, we present a rapid and cost-effective paper-based high-sensitivity vertical flow assay (hs-VFA) for quantitative measurement of cardiac troponin I (cTnI), a biomarker widely used for measuring acute cardiac damage and assessing cardiovascular risk. The hs-VFA includes a colorimetric paper-based sensor, a portable reader with time-lapse imaging, and computational algorithms for digital assay validation and outlier detection. Operating at the level of a rapid at-home test, the hs-VFA enabled the accurate quantification of cTnI using 50 μL of serum within 15 min per test and achieved a detection limit of 0.2 pg/mL, enabled by gold ion amplification chemistry and time-lapse imaging. It also achieved high precision with a coefficient of variation of <7% and a very large dynamic range, covering cTnI concentrations over 6 orders of magnitude, up to 100 ng/mL, satisfying clinical requirements. In blinded testing, this computational hs-VFA platform accurately quantified cTnI levels in patient samples and showed a strong correlation with the ground truth values obtained by a benchtop clinical analyzer. This nanoparticle amplification-based computational hs-VFA platform can democratize access to high-sensitivity point-of-care diagnostics and provide a cost-effective alternative to laboratory-based biomarker testing.

20 August 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
RGRajesh Ghosh
Rajesh Ghosh
HJHyou-Arm Joung
Hyou-Arm Joung
AGArtem Goncharov
Artem Goncharov
BPBarath Palanisamy
Barath Palanisamy
KNKevin Ngo
Kevin Ngo
DCDino Di Carlo
Dino Di Carlo
Point-of-care serological and direct antigen testing offers actionable insights for diagnosing challenging illnesses, empowering distributed health systems. Here, we report a POC-compatible serologic test for Lyme disease (LD), leveraging synthetic peptides specific to LD antibodies and a paper-based platform for rapid, and cost-effective diagnosis. Antigenic epitopes conserved across Borrelia burgdorferi genospecies, targeted by IgG and IgM antibodies, are selected to develop a multiplexed panel for detection of LD antibodies from patient sera. Multiple peptide epitopes, when combined synergistically with a machine learning-based diagnostic model achieve high sensitivity without sacrificing specificity. Blinded validation with 15 LD-positive and 15 negative samples shows 95.5% sensitivity and 100% specificity. Blind testing with the CDC’s LD repository samples confirms the test accuracy, matching lab-based two-tier results, correctly differentiating between LD and look-alike diseases. This LD diagnostic test could potentially replace the cumbersome two-tier testing, improving diagnosis and enabling earlier treatment while facilitating immune monitoring and surveillance.

7 September 2019 in Langmuir
Verified
Journal Article
Closed access
RGRajesh Ghosh
Rajesh Ghosh
HHHaritha Hareendran
Haritha Hareendran
PSPushpavanam Subramaniam
Pushpavanam Subramaniam