Barath Palanisamy

Mr. Barath Palanisamy

University of California, Davis
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
GHGyeo-Re Han
Gyeo-Re Han
AGArtem Goncharov
Artem Goncharov
MEMerve Eryilmaz
Merve Eryilmaz
Shun YeShun Ye
Shun Ye
Barath PalanisamyBarath Palanisamy
Barath Palanisamy
Aydogan OzcanAydogan Ozcan
Aydogan Ozcan
The landscape of diagnostic testing is undergoing a significant transformation, driven by the integration of artificial intelligence (AI) and machine learning (ML) into decentralized, rapid, and accessible sensor platforms for point-of-care testing (POCT). The COVID-19 pandemic has accelerated the shift from centralized laboratory testing but also catalyzed the development of next-generation POCT platforms that leverage ML to enhance the accuracy, sensitivity, and overall efficiency of point-of-care sensors. This Perspective explores how ML is being embedded into various POCT modalities, including lateral flow assays, vertical flow assays, nucleic acid amplification tests, and imaging-based sensors, illustrating their impact through different applications. We also discuss several challenges, such as regulatory hurdles, reliability, and privacy concerns, that must be overcome for the widespread adoption of ML-enhanced POCT in clinical settings and provide a comprehensive overview of the current state of ML-driven POCT technologies, highlighting their potential impact in the future of healthcare.

15 May 2025 in ACS Sensors
Verified
Journal Article
Open access
JJJaehyung Jeon
Jaehyung Jeon
HCHeeseon Choi
Heeseon Choi
GHGyeo-Re Han
Gyeo-Re Han
RGRajesh Ghosh
Rajesh Ghosh
Barath PalanisamyBarath Palanisamy
Barath Palanisamy
Sungsu ParkSungsu Park
Sungsu Park
Microfluidic paper-based analytical devices (μPADs) are powerful tools for diagnostic and environmental monitoring. Being affordable and portable, μPADs enable rapid detection of small molecules, heavy metals, and biomolecules, thereby decentralizing diagnostics and expanding biosensor accessibility. However, the reliance on two-dimensional fluid flow restricts the utility of conventional μPADs, presenting challenges for applications that require simultaneous multibiomarker analysis from a single sample. Vertical flow paper-based analytical devices (VF-μPADs) overcome this challenge by allowing axial fluid movement through paper stacks, offering several advantages, including (1) enhanced multiplexing capabilities, (2) reduced hook effect for improved accuracy, and (3) shorter assay times. This review provides an overview of VF-μPADs technologies, exploring structural and functional performance trade-offs between VF-μPADs and conventional lateral flow systems. The sensing performance, fabrication methods, and applications in in vitro diagnostics and environmental monitoring are discussed. Furthermore, critical challenges─such as fabrication complexity, data analysis, and scalability─are addressed, along with proposed strategies for mitigating these barriers to facilitate broader adoption. By examining these strengths and challenges, this review presents the potential of VF-μPADs to advance point-of-care testing, particularly in resource-limited settings.

14 December 2018 in Journal of Biological Engineering
Verified
Journal Article
Open access
PDF file
JGJoshua Garrison
Joshua Garrison
ZLZidong Li
Zidong Li
Barath PalanisamyBarath Palanisamy
Barath Palanisamy
LWLing Wang
Ling Wang
ESErkin Seker
Erkin Seker
Biological systems have complicated environmental conditions that vary both spatially and temporally. It becomes necessary to impose time-varying soluble factor concentrations to study such systems, including cellular responses to pharmaceuticals, inflammation with waxing and waning cytokine concentrations, as well as circadian rhythms and their metabolic manifestations. There is therefore a need for platforms that can achieve time-varying concentrations with arbitrary waveforms. To address this need, we developed a microfluidic system that can deliver concentration waveforms in a fast and accurate manner by adopting concepts and tools from electrical engineering and fluid mechanics. Specifically, we employed pulse width modulation (PWM), a commonly used method for generating analog signals from digital sources. We implement this technique using three microfluidic components via laser ablation prototyping: low-pass filter (lower frequency signals permitted, high frequency signals blocked), resistor, and mixer. Each microfluidic component was individually studied and iteratively tuned to generate desired concentration waveforms with high accuracy. Using fluorescein as a small-molecule soluble factor surrogate, we demonstrated a series of concentration waveforms, including square, sawtooth, sinusoidal, and triangle waves with frequencies ranging from 100 mHz to 400 mHz. We reported the fabrication and characterization of microfluidic platform that can generate time-varying concentrations of fluorescein with arbitrary waveforms. We envision that this platform will enable a wide range of biological studies, where time-varying soluble factor concentrations play a critical role. In addition, the technology is expected to assist in the development of biomedical devices that allow precise dosing of pharmaceuticals for enhanced therapeutic efficacy and reduced toxicity.

24 November 2025 in ACS Sensors
Verified
Journal Article
Closed access
MLMihye Lee
Mihye Lee
SASamiha Ahmed
Samiha Ahmed
LTLin Tong
Lin Tong
MUMert Kerem Ulku
Mert Kerem Ulku
NCNandita Chaturvedi
Nandita Chaturvedi
DCDino Di Carlo
Dino Di Carlo

16 February 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Barath PalanisamyBarath Palanisamy
Barath Palanisamy
NGNoah Goshi
Noah Goshi
ESErkin Seker
Erkin Seker
Sustained release and replenishment of the drug depot are essential for the long-term functionality of implantable drug-delivery devices. This study demonstrates the use nanoporous gold (np-Au) thin films for in-plane transport of fluorescein (a small-molecule drug surrogate) over large (mm-scale) distances from a distal reservoir to the site of delivery, thereby establishing a constant flux of molecular release. In the absence of halides, the fluorescein transport is negligible due to a strong non-specific interaction of fluorescein with the pore walls. However, in the presence of physiologically relevant concentration of ions, halides preferentially adsorb onto the gold surface, minimizing the fluorescein–gold interactions and thus enabling in-plane fluorescein transport. In addition, the nanoporous film serves as an intrinsic size-exclusion matrix and allows for sustained release in biofouling conditions (dilute serum). The molecular release is reproducibly controlled by gating it in response to the presence of halides at the reservoir (source) and the release site (sink) without external triggers (e.g., electrical and mechanical).

8 January 2026 in ACS Sensors
Verified
Journal Article
Closed access
RTRui-Chian Tang
Rui-Chian Tang
Barath PalanisamyBarath Palanisamy
Barath Palanisamy
RGRajesh Ghosh
Rajesh Ghosh
MLMihye Lee
Mihye Lee
GHGyeo-Re Han
Gyeo-Re Han
DCDino Di Carlo
Dino Di Carlo