9 April 2025 in IEEE Transactions on Radiation and Plasma Medical Sciences
In nuclear medicine imaging systems, intrinsic spatial resolution of the detector is one of the most important performance metrics. In this work, we aim to develop a high-resolution single photon emission computed tomography (SPECT) detector using pixelated Cedoped gadolinium aluminum gallium garnet (GAGG:Ce) scintillators and silicon photomultiplier (SiPM) arrays. Special attention is paid to improving the resolving capability of edge crystals. We propose to place optical barrier (OB) slits onto the light guide that enhances the difference in light distribution for edge crystals. We experimentally optimize OB designs for two scintillator arrays, named as Array-ESR and Array-BaSO4, which uses enhanced specular reflector (ESR) film and barium sulfate (BaSO4) as the reflectors respectively. Both arrays have 31 × 31 0.8 mm × 0.8 mm × 6 mm GAGG:Ce crystals. We introduce the flood map quality (FMQ) parameter to assess the separation of responses of neighboring crystals. The results demonstrate that for Array-ESR, an optimal light guide with two 7° OB slits and two 11° OB slits resolves 92.40 % crystals with an energy resolution of 13.19 ± 0.68%. The FMQ is 1.52 ± 0.38. For Array-BaSO4, the optimal design is a light guide with four 7° OB slits. 98.75 % crystals are resolvable with an energy resolution of 15.33 ± 0.96 % and FMQ parameter of 1.81 ± 0.45. Overall, Array-BaSO4 is more suitable for building SPECT detector for its good crystal resolving performance and fabrication convenience. This study proposes a practical sub-millimeter pixelated SPECT detector design with no detection dead space and compact electronics. It is promising for being used to build largescale detectors for high resolution SPECT systems.
3 April 2025 in IEEE Transactions on Radiation and Plasma Medical Sciences
Proton therapy is one of the most advanced radiotherapy techniques. Despite its advantages in dose delivery, it has not yet achieved significant clinical benefits for patients due to uncertainties in proton range. Accurate, real-time monitoring of proton dose and range is crucial for ensuring the precision of proton therapy. In prior work, a dual-head prompt gamma imaging system was proposed and evaluated through Monte Carlo simulations, demonstrating high spatial resolution and sufficient detection efficiency for proton pencil beam imaging at clinical doses. This study focuses on the assembly, calibration, and testing of one of the detectors in this system. Spatial resolution and detection efficiency were evaluated using a 22Na point source, while range shift detection and accuracy were assessed with 60 and 100 MeV proton beams under low proton count conditions. The single-head system achieved a detection efficiency of 0.22% and a full-width at half-maximum (FWHM) spatial resolution of 2.8 mm at the center of the field of view (FOV). The system was able to detect a 1 mm range shift by identifying the most distal edge position (MDEP) of the prompt gamma profile. The detector demonstrated a range accuracy of less than 1 mm at typical count levels for a single spot in proton pencil beam scanning. The results suggest that this system performs well in terms of both detection efficiency and spatial resolution, and the system could achieve real-time range verification with high accuracy.
2 February 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
1 May 2026 in IEEE Transactions on Medical Imaging
Stemmed from our novel single-photon imaging concept of detector self-collimation-which leverages detectors themselves as collimators to overcome the inherent resolution-sensitivity trade-off in conventional SPECT-this study presents the design and evaluation of the first full-ring self-collimation SPECT (SC-SPECT) scanner for small animal imaging. The system features four concentric detector rings and two interchangeable high-aperture-ratio tungsten collimator rings optimized for high-resolution (HR) and general-purpose (GP) imaging applications. Detector rings contain 480, 720, 960, and 1,200 evenly distributed GAGG(Ce) scintillators, each measuring 0.84 mm (tangential) × 6 mm (radial) × 20 mm (axial) and separated by 0.84-mm gaps to enable effective photon collimation. Inner detector rings and the collimator ring collectively provide collimation for photons reaching subsequent outer rings. Dual-end SiPM readouts facilitate axial depth-of-interaction measurements. Phantom and mouse studies are performed to assess the system's resolution, sensitivity, and field-of-view volume, and SC-SPECT demonstrates generally superior performance compared with state-of-the-art small-animal SPECT systems. Mouse bone images using 99mTc-MDP show CT-like resolution, clearly delineating detailed tracer uptake distributions within small structures such as mouse paws and skulls, indicating a significant technological advancement in small-animal SPECT imaging.