18 June 2020 in IEEE Transactions on Instrumentation and Measurement
This letter proposes a novel fault diagnosis method to detect the fault of high voltage capacitor (HVC) for DC filter (DCF) in high voltage direct current (HVDC) systems. The proposed diagnosis principle is developed through identifying the change of HVC capacitance, which is calculated in real-time using the measured voltage and current of DCF. Compared with the traditional methods, the proposed approach is superior in detecting successive faults and symmetrical faults since any HVC fault will change the capacitance parameter of HVC essentially. Simulation and experimental results verify the performance and superiority of the presented method.
16 November 2022 in IEEE Transactions on Power Delivery
The protection of high voltage direct current (HVDC) transmission line is the key to development of the HVDC transmission technology. To deal with the problem that the traditional traveling wave protection (TWP) has low sensitivity under high resistance faults, an improved TWP scheme based on the compensation of the line-mode component of fault voltage (LMCFV) is proposed. The expressions of the LMCFV of HVDC system at different fault locations are derived. Conclusions can be drawn that the LMCFV and fault resistance are linear when the DC line fault occurs, whereas the linear state will be broken for the external fault. Based on this, the LMCFV for the metal fault occurring at the DC line midpoint is used as the reference value to compensate for the faults in other cases of the HVDC systems. The protection scheme constructed based on the compensatory LMCFV and compensation coefficient can accurately identify fault of the DC line. Finally, a ${\pm }$ 800 kV model of HVDC systems is built in PSCAD to verify the protection performance. The effect of fault resistance can be eliminated by compensatory LMCFV, and the DC line fault can be quickly and reliably identified by the simulation results.
8 March 2022 in IEEE Transactions on Instrumentation and Measurement
The ac line fault could lead to the operation of converter station protection for high voltage dc (HVDC) systems. In order to avoid the false operation of converter station protection, a novel fault section identification scheme based on energy relative entropy is proposed. The fault characteristics of internal and external for converter station section are analyzed, and it is found that the difference of forward current traveling wave and backward current traveling wave is obvious when the fault occurs in different section. The difference between the forward and backward current traveling wave is represented by the S-transform energy relative entropy. The S-transform energy relative entropy for the external ac line fault is smaller than that of the internal fault of converter station. The performance and effectiveness of the proposed section identification method are evaluated and verified based on simulation and experiment. Finally, the adaptation is studied by considering the fault position, fault type, fault initial angle, transition resistance, and noise. The proposed method can accurately identify the fault of ac system from the converter station and effectively prevent the converter station protection from incorrect operation.
1 October 2024 in IEEE Transactions on Power Delivery
A high voltage direct current (HVDC) transmission line fault location scheme based on the fitting coefficients of the line-model component of fault voltage (LMCFV) wavefront is proposed to address the problem of reduced accuracy in existing DC line fault location methods due to fault resistance. Firstly, the propagation characteristics of the LMCFV on the DC line are analyzed, and it is found that the LMCFV is mainly affected by the value of the fault resistance at the fault point and the dispersion during the DC line propagation. Therefore, a logistic function is used to fit the wavefront of the LMCFV, and a power function is constructed based on the mapping relationship between the fitting coefficients and the fault location. Finally, the fault position of the DC line is located by using the fitting coefficients of the LMCFV wavefront. The proposed method is implemented in a hybrid cascaded HVDC transmission system, and simulation results demonstrate that the fault location method is immune to the effects of fault resistance and does not require accurate wave speed. The proposed method exhibits high accuracy in fault location
9 June 2026 in IEEE Transactions on Power Delivery
To address the issue of long-time protection gap between the traveling wave protection and pilot differential protection actions for high voltage direct current (HVDC) transmission lines, a novel protection method for hybrid cascaded ultra high voltage direct current (HCUHVDC) line based on control response characteristics is proposed. The variations in the rectifier converter valve trigger angle and the inverter DC current command value are analyzed for faults at different locations. The command value change of DC current is characterized by the time difference between the start of the trigger angle increase and the start of the command value decrease. Characteristic curves of the increment of the trigger angle and the time difference are constructed for forward out-of-zone faults with different fault severity levels on the DC line. The point composed of the trigger angle increment and the time difference for the DC line fault is in the upper right corner of the point for the forward external fault. Based on this feature, a fault identification criterion is constructed. Finally, a ${\pm }$800kV hybrid cascaded model is built in PSCAD to verify the protection performance. Results show that the proposed scheme can accurately identify DC transmission line faults, with strong robustness against transition resistance and noise interference, thus possessing promising engineering application prospects.