Thermal management is often considered a bottleneck in the pursuit of the next generation hydrogenerator in the electric power system. Overheating of the complex rotor parts has become one of the main problems affecting safe and stable hydrogenerator operation. In this paper, a 250 MW hydrogenerator is analyzed. The transient electromagnetic field of the hydrogenerator is calculated and the losses of the rotor parts are obtained. The rotation of the hydrogenerator rotor is considered. Three-dimensional fluid and thermal mathematic and physical models of the hydrogenerator are established. The loss values from electromagnetic field calculations are applied to the rotor parts as heat sources in the temperature field. After solving the fluid and thermal equations of fluid-solid conjugated heat transfer, influence of the structures of rotor support plate, rotor pole body insulation, and rotor excitation winding on the fluid flow and temperature distribution in the rotor region of hydrogenerator is studied using the finite volume method. The calculated temperature result of rotor excitation winding is compared with the measured value. The calculated temperature result agrees well with the measured value. It provides an important reference for optimizing the rotor structure of the larger hydrogenerator.
Ventilation cooling design is one of the key technologies during the design of large hydrogenerator. With the increase of hydrogenerator capacity, the overheating problem of rotor region become more and more serious. In this paper, a 250 MW hydrogenerator is analyzed. The transient electromagnetic field of the hydrogenerator is calculated. The losses (heat sources) of rotor components in the rotor region of the hydrogenerator are determined. Three-dimensional fluid and thermal coupled mathematic model of the hydrogenerator rotor region is established. The rotor rotation of the hydrogenerator is considered. The distribution of complex fluid velocity in the rotor region is calculated using the finite volume method. The influence of fluid velocity in the different directions on the temperature of the rotor excitation winding is studied under the different flow rates in the rotor region. The surface heat-transfer coefficient distribution of the rotor components is determined. The temperature distribution of the rotor excitation winding, rotor pole body, rotor press plate, rotor damping bar, and rotor end ring is obtained. The calculated temperature results match well with test values. These provide an important reference for the rotor structural design and optimization of larger hydrogenerator.