Xin Tang

Xin Tang

Auto-generated profile, based on publicly available information

Xin Tang

National Key Laboratory of Electromagnetic Energy, Naval University of Engineering, Wuhan, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HSHaolan Shen
Haolan Shen
XTXin Tang
Xin Tang
YLYifei Luo
Yifei Luo
FXFeng Xie
Feng Xie
ZSZenan Shi
Zenan Shi
The accuracy of data-driven open-circuit fault diagnosis methods is affected by varying operating conditions. This issue is often ignored. In this paper, an improved convolutional neural network (CNN) and a sample amplification method are proposed to eliminate the influence of varying operating conditions on the online open-circuit fault (OCF) diagnosis for neutral point clamped (NPC) inverter. Firstly, 73 types of open-circuit fault sample collection can be greatly reduced to 14 by following the sample amplification method. The signals of any phase can be generated by a single fundamental period signal. This provides a significant savings in sample collection time. Secondly, the spatial attention mechanism (SAM) is added after the first convolutional layer of the CNN model. The feature extraction capability of the model is enhanced for time-domain waveform scaling under variable operating conditions. Simultaneously, the last full connection (FC) layer of the CNN model is retained and the other FC layers are substituted with a global maximum pooling (GMP) layer. This has the advantage of reducing the number of network parameters and further conserving the effective feature information. In conclusion, the experimental results show that the sample amplification method and the improved CNN model for online fault diagnosis under varying operating conditions exceed 99% accuracy. The SAMCNN-GMP is more effective and stable than the CNN model.

26 August 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YHYongle Huang
Yongle Huang
XTXin Tang
Xin Tang
YLYifei Luo
Yifei Luo
FXFei Xiao
Fei Xiao
BLBinli Liu
Binli Liu
XLXin Li
Xin Li
Fatigue life of insulated gate bipolar transistor modules (IGBTs) is critical to the reliable application during their long-term servicing. At present, time-consuming and costly power cycling tests are commonly used to obtain the fatigue life model of power electronics devices. In this article, a lower cost and higher efficiency method for the evaluation on the fatigue life of IGBTs was proposed based on variable-parameter power cycling. First, theoretical feasibility of the proposed method was discussed based on fatigue theory. Then, details concerning on the proposed method were described combining with the power cycling data obtained from electro-thermal coupling simulations. Finally, power cycling under both constant and variable parameter was carried out to IGBT modules for experimental verifications. Results dedicate that the fitted fatigue life deduced from the degradation curve of electro-thermal characteristics of IGBTs under variable-parameter power cycling was well consistent with that directly measured from constant-parameter power cycling. It results in an order of magnitude increase in test efficiency and an order of magnitude decrease in costs, which brings huge economic benefit and high efficiency to the fatigue life evaluation of IGBTs.

17 December 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
HSHaolan Shen
Haolan Shen
XTXin Tang
Xin Tang
YLYifei Luo
Yifei Luo
ZSZenan Shi
Zenan Shi
THTongyao Han
Tongyao Han
The dual active bridge (DAB) converter is a popular DC–DC converter topology for high-power applications. An open-circuit fault (OCF) in DAB converter can produce a DC bias in its transformer currents, which can saturate the transformer, resulting in significant power losses and power quality deterioration. In this paper, a refined modeling and an online OCF diagnosis method are proposed for OCF in DAB converters. Firstly, the causes of voltage and current waveform distortion caused by OCF are analyzed in detail. The reasons for differences in transformer voltage and current waveforms due to different OCF positions are studied. The importance of critical parameters such as the magnetizing inductance of transformers and parasitic capacitance of power switches to analysis of circuit operation characteristics under OCF conditions is clarified. Based on this theoretical research, a refined DAB converter modeling incorporating critical parameters is proposed. In contrast to current models, this proposed model offers improved accuracy in depicting variations of primary-side electrical parameters under OCF conditions. Additionally, an OCF diagnosis method is proposed. This method utilizes the cycle-average value of the transformer primary-side current for OCF detection and localization. Unlike prior methods, the proposed method does not necessitate supplementary hardware sensing conditions, nor does it require the converter to operate in a specific switching state. Finally, the online deployment of OCF diagnosis method based on FPGA is completed. Experimental results verify that the proposed model effectively simulates variations in the primary-side and secondary-side currents of the transformer, as well as the magnetizing current, under OCF conditions. As a fault feature, the mean absolute error (MAE) of the primary-side current is within 0.5A and the period average error is within 0.2%. Moreover, the online OCF diagnosis method enables OCF detection within 1 switching cycle and OCF localization within 6 switching cycles.