The impact of Photovoltaic (PV) installations on the fire safety of buildings must be considered in all building projects where such energy systems are established. The holistic fire safety of the building largely depends on how the fire safety of the PV installation is considered by the different actors during the design and construction process. Research has therefore been undertaken to study how performance-based regulations in combination with the lack of national guidelines affect the overall fire safety considerations for PV installations in Norway. Four factors were found to govern to which extent PV installations are emphasised in the fire safety design phase: (1) whether the building was first of its kind as a pioneering building, (2) whether the building was built before or after the publication of the 2018 revision of the norm NEK 400, (3) The level of knowledge and experience of the fire safety consultant, which in turn affects the use of performance-based engineering tools and the level of detailing in the design and construction phases, and (4) The degree of integration in the building. The main goal of the study is to give an insight and a contribution to the development of in-depth knowledge on how fire safety design for PV installations on buildings is handled in Norway, which may also be relevant to other countries with similar performance-based regulations.
Design models are commonly used in fire safety design of light timber frame assemblies. Parameters for use in the models are available for rectangular members with mineral wool, wood fibre or cellulose insulation and for assemblies with I-joists and mineral wool. For assemblies where I-joists and combustible insulations are combined, design parameters are missing. Five fire experiments with two I-joist types and four combustible insulation products have been conducted. The aim was to study charring of I-joist flanges and recession rates of combustible insulations and in addition, to compare their behaviour to the new and existing models of Eurocode 5. Charring rates for the flanges were 0.40–0.76 mm/min and 0.54–1.72 mm/min for the protected and post-protected phase, respectively. Rates decreased with increasing flange size. Charring rates for flanges of solid wood and LVL were comparable. The results show that lateral charring of I-joist flanges can be significant in the protected phase. The tested insulation products showed a lower recession rate than values reported for glass wool insulation, with a more pronounced difference for wood fibre and cellulose insulations. The low recession rates compared to previously reported generic values can possibly be explained by better product-specific properties, negligible shrinking and slightly different test set-up. The insulation stayed well in place after gypsum board fall-off and best-practice for keeping the insulation in place is given. The results, completed with future loaded full-scale tests, can give basis for further development of design models for assemblies with I-joists and combustible insulations.